(L)VRCTL(R)8*1D, *2C, *3C VRCDTL(R)*C (L)VRCTL(R)DD*C
INSTALLATION, CARE & USE MANUAL
Manual de Instalación, Cuidado y Utilización
Manuel d’installation/entretien/utilisation
VRCTL™ Series Barrier-Free Water Coolers
VRCTL™ La Barrera de la serie Liberta Agua Coolers
VRCTL™ Coolers d’Eau de Barrière-Libère de feuilleton
Model VRCTL8
Model VRCTLR8
Page 1
98958C (Rev. D- 12/16)
(L)VRCTL(R)8*1D, *2C, *3C VRCDTL(R)*C (L)VRCTL(R)DD*C
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad.
Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil.
Uses HFC-134A refrigerant
Usa refrigerante HFC-134A
Utilise du uide frigorigéne HFC-134A
15, 17, 18
9, 23, 30
22
23
34
21
27
10
22
20
16
6
4
50
23
6
1
6
25
6
1
9, 23,30
25
See Fig. 4
See Fig. 6
37
29
45
35
38 (TL)
8
39 (TLR)
40 (TL)
41 (TLR)
NOTE: Non-refrigerated units do not include all electrical and refrigeration components
shown above.
Other components and rough-in are the same as shown.
NOTA: Las unidades no frigoricadas no incluyen todos los componentes eléctricos y de
la refrigeración demostrados arriba. Otros componentes y a’spero-en son iguales según
lo demostrado.
NOTE: Les unités non frigoriées n’incluent pas tous les composants électriques et de
réfrigération montrés ci-dessus. D’autres composants et rugueux-dans sont identiques
que montrés.
98958C (Rev. D - 12/16)
Page 2
45
21
42
34
21
14
13
19
11
36
12
2
45
35
FIG. 1
VRCTL8 SHOWN
(L)VRCTL(R)8*1D, *2C, *3C VRCDTL(R)*C (L)VRCTL(R)DD*C
6 3/4"
173mm
* ADA REQUIREMENT
* REQUISITO DE A.D.A.
12 5/16"
18 5/8"
474mm
HANGER BRACKET
8"
FIJADOR DE SUSPENSION
SUPPORT DE SUSPENSION
2 5/8"
67mm
39 1/2"
1003mm
203mm
31 7/8"
810mm
RIM HEIGHT
ALTURA DEL
HEIGHT
ORIFICE
ORIFICIO
L'ORIFICE
ALTURA DEL
HAUTEUR DE
4 3/4"
121mm
C
ORIFICIO
L 'ORIFICE
HAUTEUR DE
HEIGHT
ORIFICE
32 15/16"
837mm
ALTURA DEL
312mm
27"
686mm
*
ORIFICIO
L'ORIFICE
HAUTEUR DE
* EXIGENCE ADA
VRCTL8
5 3/4"
18 1/16"
459mm
5 3/4"
25 1/8"
638mm
20 1/8"
511mm
A
E
D
5 3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
C
L
F
18 3/4"
476mm
13 7/8"
351mm
B
6 1/4"
159mm
4 1/2"
114mm
3 1/2"
89mm
146mm
5 3/4"
146mm
1 1/2"
35mm
1 3/8"
35mm
C
L
1 3/8"
38mm
2 7/16"
63mm
10"
254mm
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
5"
127mm
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
146mm
E
F
20 3/8"
6 1/2"
166mm
518mm
8mm (10 TROUS)
37 1/2"
8mm (10 AGUJEROUS)
952mm
5/16" (8mm) DIA. (10 HOLES)
PARED
MUR
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2” DE SORTIE D’EAU. STUB 2 HORS DU MUR
PURGADOR DE 1-1/2 NO PROPORCIONADO
SIPHON 1-1/2 NON FOURNI
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/2 TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
FIG. 2
Page 3
98958C (Rev. D- 12/16)
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL