Elkay VRCTL8WS, VRCTLDDWS User Manual

SPECIFICATIONS
Vandal-Resistant EZH2O® Bottle Filling Station
with Bi-Level Vandal-Resistant Cooler
PRODUCT SPECIFICATION
Unit shall include bi-level electric water cooler with bottle lling station. VRCTL8WS
shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. VRCTLDDWS shall deliver non-chilled drinking water. Units shall be stainless
steel construction and include vandal-resistant bubbler. Bottle lling unit shall
include an automatic 20-second shut-off timer. Shall include Green Ticker™
displaying count of plastic bottles saved from waste. Bottle ller shall provide
1.1 - 1.5 gpm ow rate with laminar ow to minimize splashing. Unit shall meet ADA guidelines. Unit shall be lead-free design which is certied to
NSF/ANSI 61 and 372 and meets federal and state low-lead requirements.
Unit shall be certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
Vandal-resistant pushbutton activation
Automatic 20-second shut-off
Quick Fill Rate: 1.1 gpm (VRCTL8WS); 1.5 gpm (VRCTLDDWS)
Laminar Flow provides minimal splash
Real Drain System eliminates standing water
Visual User Interface display includes:
Innovative Green Ticker™ counts bottles saved from waste
Includes Vandal-resistant bubbler
• Cooler panel nish: Stainless Steel
COOLING SYSTEM (Model VRCTL8WS only)
Compressor: Hermetically sealed, reciprocating type, single phase. Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
Cooling unit: Combination tube-tank type. Self-cleansing. Continuous copper tubing with stainless steel tank. Fully insulated with EPS foam which meets UL requirements for self-extinguishing material.
Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube.
Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
Models VRCTL8WS & VRCTLDDWS
RATED FOR INDOOR AND OUTDOOR USE
Models VRCTL8WSK or VRCTLDDWSK
CONSTRUCTION
Stainless steel basin with integral drain
Galvanized structural steel cooler chassis provides structural
integrity
• Stainless steel construction bottle ller
Cooler cabinet is stainless steel construction
Vandal-resistant bubbler is one-piece, heavy-duty chrome plated
WARRANTY
5 Year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever
date falls rst.
CAPACITIES CHART
Model
VRCTL8WSK 115V / 60Hz 8 GPH 5.0 370 11 4
VRCTL8WS2K 220V / 50Hz 6.7 GPH 2.5 370 11 4 ++
VRCTL8WS3K 220V / 60Hz 8 GPH 2.5 370 114 ++
VRCTLDDWSK 115V / 60Hz - 1.0 15 86
VRCTLDDWS2K 220V / 50Hz - 0.5 15 86 ++
VRCTLDDWS3K 220V / 60Hz - 0.5 15 86 ++
**Based on 80°F inlet water and 90°F ambient air temp for 50°F chilled drinking water. ++Complies; not third party certied.
In keeping with our policy of continuing product improvement, Elkay
reserves the right to change specication without notice. Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling
Capacity**
F.L. Amps
Rated Watts
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
Approx.
Shipping
Wt. (lb)
UL399 and
CAN/CSA
22.2 No. 120
Certied
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
ADA
Compliant
ANSI/NSF
61 & 372
Certied
SPEC14-79 (10/2014)
GreenSpec®
Listed
© 2014 Elkay
Vandal-Resistant EZH2O® Bottle FillingStation with Bi-Level Vandal-Resistant Cooler Models VRCTL8WS & VRCTLDDWS
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building buy may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown.
16 5/16
7
178mm
32mm
1 1/4
D
414mm
1 1/4
32mm
7
178mm
11/16
18mm
3 1/2
89mm
4 1/2
114mm
159mm
6 1/4
18 1/2
470mm
E
A
F
13 7/8
352mm
1/4" x 1/2" (6mm x 13mm) OBROUND HOLES (5)
5/16
8mm
37 1/2
953mm
O
20 3/8
518mm
HOLES (5)
6 1/2
165mm
7 1/4
185mm
2 9/16
65mm
E
127mm
18 1/16
459mm
5 3/4
5 3/4
146mm
146mm
1 3/8
1 3/8
35mm
34mm
4 1/2
116mm
18mm
63mm
10
254mm
B
3/4
2 1/2
FINISHED FLOOR
F
5
ROUGH-IN DIMENSIONS
RATED FOR INDOOR AND OUTDOOR USE
NOTICE:
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
18 11/16
474mm
18 3/4
476mm
20 1/8
511mm
25 1/8
638mm
51 1/8
1299mm
48
1220mm
39 9/16
1005mm
ORIFICE
HEIGHT
838mm
33
ORIFICE
HEIGHT
31 13/16 808mm
RIM HEIGHT
REQUIREMENT
2 5/8
66mm
686mm
ADA
HANGER
BRACKET
8
203mm
FILTER
C
27
12 5/16 312mm
6 3/4
172mm
105mm
FINISHED FLOOR
4 1/8
1 1/2
37mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (38mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: Installations Must Use Ground Fault Circuit Interrupter. (GFCI)
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in U.S.A.
© 2014 Elkay