Elkay VRCHD8S Specifications

SPECIFICATIONS
Heavy-Duty, 14 Gauge Wall-Mount Water Cooler
Vandal-Resistant, Barrier Free Access
Models VRCHD8S*, VRCHDDS and VRCHDTL(8-DD)S*C
PRODUCT SPECIFICATION
Self-contained, heavy-duty, vandal-resistant water cooler. Shall include 14 GA stainless steel welded construction for extreme tamper-resistance
and curved prole for safety. Front pushbutton activation must be
vandal-resistant and not easily removed without special tools. Shall include vandal-resistant StreamSaver™ bubbler and integral drain in basin. Shall include louvered screens with holes sized to prevent easy tampering. Shall include etched name on front; removable adhesive labels not allowed. Models VRCHD(TL)8 shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. Models VRCHD(TL)DD shall deliver non-chilled drinking water. Unit shall meet ADA guidelines. Unit shall be
lead-free design which is certied to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Ideal for applications prone to tampering such as prisons and educational facilities with curved prole offering a safe and unobtrusive
design
One-piece 14 GA stainless steel heavy-duty welded body includes basin with integral drain and side panels; no fasteners
Gap-free panel joins to eliminate tamper access points
• Durable satin nish that resists stains and corrosion
Vandal-resistant, self-closing pushbutton which requires tooling to
prevent easy removal. Meets ADA activation force guidelines
Vandal-resistant, heavy-duty one-piece drain formed into basin
• Vandal-resistant, heavy-duty, one-piece StreamSaver™ water-efcient
bubbler.
Rated for indoor and outdoor use
COOLING SYSTEM (Models VRCHD(TL)8 only)
Compressor: hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication.
Condenser: Fan cooled. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Continuous copper tubing
with stainless steel tank. Fully insulated with EPS foam which meets UL requirements for self-extinguishing material.
Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
RATED FOR INDOOR AND OUTDOOR USE
Model
VRCHDTL8SC
Model VRCHD8S
CONSTRUCTION
Frame: Galvanized structural steel chassis supports cooler housing
Housing: Heavy-duty 14 gauge stainless steel cabinet with front access panel and integral basin
Screened vents: Perforated vent screens prevent objects from being inserted into cooler
Vandal-resistant StreamSaver™ Bubbler: One-piece, heavy-duty, solid construction. Reduces the ow of water by nearly 40%
* but maintains a steady, satisfying water stream. Keyed into position to prevent rotation. *Over average market performance.
Vandal-resistant Drain: Heavy-duty, one-piece construction
• Vandal-resistant Pushbutton: Heavy-duty, self-closing, easy to
operate. Allows front access stream height adjustment.
• Note - Flow regulator provides constant stream from 20 to105 psi
water pressure.
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever
date falls rst.
CAPACITIES CHART
Model Voltage / Hertz
VRCHD8S 115V / 60 Hz 8 GPH 4.0 370 76
VRCHD8S2JO 220V / 50 Hz 6.7 GPH 2.0 370 76
VRCHD8S3JO 220V / 60 Hz 8 GPH 2.0 370 76
VRCHDTL8SC 115V / 60 Hz 8 GPH 4.0 370 110
VRCHDTL8S2JOC 220V / 50 Hz 6.7 GPH 2.0 370 110
VRCHDTL8S3JOC 220V / 60 Hz 8 GPH 2.0 370 110
VRCHDDS
VRCHDTLDDSC
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
Chilling**
Capacity
F.L.
Amps
Rated Watts
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Approx.
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.
Wt.
47
85
ADA
Compliant
UL399 and CAN/
CSA 22.2 No. 120
Certied
++
++
++
++
SPEC12-59 (11/2014)
ANSI/NSF
61 and 372
Certied
© 2014 Elkay
Heavy-Duty, 14 Gauge Wall-Mount Water Cooler Vandal-Resistant, Barrier Free Access Models VRCHD8S* and VRCHDDS
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown.
1/4” O.D. TUBE
WATER INLET
TO COOLER
5/16" ( 8 mm ) DIA. (5 HOLES)
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
5 3/4" 146mm
(NOT FURNISHED)
18 3/16" 463mm
1 3/8" 35mm
B
BUILDING WATER
INLET
SERVICE STOP
1 3/8" 35mm
5 3/4" 146mm
ROUGH-IN DIMENSIONS
RATED FOR INDOOR AND OUTDOOR USE
Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
3" (3")
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
18 9/16" 471mm
HANGER BRACKET
4 9/16" 116mm
2 1/2" 63mm
3 1/2" 89mm
4 1/2" 114mm
11/16" 18mm
E
12 5/8" 320mm
7 1/4" 185mm
2 5/8" 67mm
29 5/8" 753mm
25" 635mm
21 3/8" 543mm
18 3/8" 467mm
E
D
A
F
5" 127mm
C
L
9 15/16" 252mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/4” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: Installations Must Use Ground Fault Circuit Interrupter (GFCI).
32 9/16" 827mm
ORIFICE HEIGHT
RIM HEIGHT
31 1/2" 800mm
27" * 686mm
REQUIREMENT
ADA
8 1/8" 206mm
6 13/16" 173mm
11 1/16" 280mm
C
6 1/2" 165mm
1 1/2" 38mm
FINISHED FLOOR
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
Printed in U.S.A.
© 2014 Elkay
Page 2
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com