SPECIFICATIONS
energy & water efficient
energy & water efficient
energy & water efficient
energy & water efficient
GENERAL
GreenSpec®Listed, energy and water efficient model. Selfcontained, double wall hung electric, refrigerated water cooler.
Vandal-resistant unit for use in high demand locations. Flow
regulator provides constant stream from 20 to 105 psi water
pressure. Rated for indoor and outdoor use.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and convenient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
CAPACITIES CHART
**GPH of 50°F
Drinking Water
Room Temperature °F
Model Volt./ Base 70°F 80°F 90°F Rated Load Glass Wt.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Filler Lbs.
VRCGRNTL8C
LVRCGRNTL8FC
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
1150V/
8.0 9.7 8.8 8.0 260 2.8 – 94
60Hz
1150V/
8.0 9.7 8.8 8.0 260 2.8 Included 98
60Hz
ENERGY-EFFICIENT COOLING SYSTEM
Motor Compressor: High-efficiency, hermetically sealed,
reciprocating type, 115 Volt/60 Hz, single phase. Sealed-in
lifetime oil supply. Equipped with electric cord and three
prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Designed for
optimized heat transfer within the evaporator. Fully insulated.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
Full Filter/ Ship.
GreenSpec®Listed, High Efficiency
Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model VRCGRNTL8C
Model VRCGRNTL8C
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
Bubbler: Water-efficient, heavy-duty, vandal-resistant bubbler in one-piece construction. Keyed into position to prevent
rotation. Meets UL requirements and all sanitary codes.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with vandal-resistant screws.
Color Selection: Stainless steel furnished as standard.
Protected by Elkay’s 5 Year Limited Warranty on the refrig-
eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkay.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 10/15) 12-57c
G r e e nS pec®L is ted, H igh E fficienc y
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OP ER ATION OF QU ICK CONNEC T FITTING S
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADACOOLER
Two S ta ti on Wa ll M o u nt Wa ter C o oler
Va nd a l - R e s is ta n t, B a rrier- F ree Ac c es s
M odel V R C GR NT L8 C
®
R O U G H - I N D I M E N S I O N S
1/4" O.D. TUBE
WATE R INL ET
TO COOLER
NOTE: W ATE R FLO W
SIMPLY PUSH IN
TUBE TO A TTAC H
A B
*
ADAREQUIREMENT
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
C = 1-1/2" TRAP NOT FURNISHED
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN.
3” (76mm) MAXIMUM OUT FROM WALL.
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
LEGEND
FINISHED FLOOR
(127mm)
5"
(511mm)
(313mm)
(114mm)
20-1/8"
(351mm)
12-5/16"
(686mm)
4-1/2"
(518mm)
(254mm)5"(127mm)
13-7/8"
27"*
(89mm)
20-3/8"
10"
3-1/2"
B
(476mm)
(638mm)
6-3/4"
18-3/4"
25-1/8"
(121mm)
(62mm)
HEIGHT
4-3/4"
2-7/16"
ORIFICE
(952mm)
F
(837mm)
37-1/2"
32-15/16"
C
(38mm)
1-1/2"
F
A
L
HEIGHT
(203mm)
C
RIM
8"
(810mm)
E
E
31-7/8"
L
C
HEIGHT
D
ORIFICE
(166mm)
(1003mm)
6-1/2"
39-1/2"
(35mm)
(35mm)
1-3/8"
1-3/8"
(146mm)
(146mm)
(10 HOLES)
(67mm)
5-3/4"
5/16" (8mm)
5-3/4"
2-5/8"
(35mm)
(35mm)
1-3/8"
1-3/8"
(146mm)
(146mm)
(473mm)
5-3/4"
5-3/4"
18-5/8"
(459mm)
18-1/16"
5/16" (8mm)
(10 HOLES)
6-1/2"
(166mm)
37-1/2"
(952mm)
20-3/8"
(518mm)
3/8" O.D. TUBE CONNECT
COLD W AT ER S UP PLY
DIRECTION
TUBE IS SECURED
IN POSITION
5-3/4"
(146mm)
E
F
5"
(127mm)
FINISHED FLOOR
SERVICE STOP
PUSH IN COLLET
TO RELEASE TUBE
C
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
1-3/8"
1-3/8"
(35mm)
(35mm)
C
L
2-7/16"
(62mm)
10"
(254mm)
INS TAL LE R PL EAS E NO TE :
BUILDING W ATE R
INLET
TH IS WATE R C OO LE R H AS B EE N D ES IGN ED AN D B UILT T O P RO VIDE W ATE R TO T HE US E R
IMP OR TANT
WH IC H H AS N OT B E EN ALTE R E D BY MAT ER IA LS IN T HE C O OL ER WAT ER WAY S . TH E
G RO UND ING O F EL EC TR IC AL E QU IPM EN T S U CH AS T EL EP HO NE, C OM PU TE RS , E TC . T O
WATE R L INE S IS A CO MMO N P RO CE DU RE . T HIS G RO UNDI NG MAY BE IN T HE BU ILDING
B UT M AY AL S O OC C UR AWAY F R OM T HE B U ILD ING . THIS GR O UN DING C AN C
E LE C TR IC AL FEE DB AC K IN TO A WATE R C O OLE R C R E ATI NG A N EL ECT R OLY SIS W HI CH
C RE ATE S A ME TALLIC TA ST E OR C AU SE S AN INCR EASE IN T HE M ETAL C ONT EN T O F T HE
WATE R . T HIS C ON DITION IS AVO IDAB LE B Y IN STA LLIN G TH E C OOL ER U SING T HE P ROPE R
MATE R IALS AS S HOW N B E LOW.
NO TIC E
TH IS WATE R C OOL ER MU ST B E C ONN EC TE D TO T HE WATE R S UP PLY USIN G A DIE LE CT R IC
C OUP LIN G. T HE C OOL ER IS F UR NIS HE D W ITH A N ON- ME TALLIC S TR AIN ER W HIC H
TH IS R E QUIR E MENT. TH E DR AIN T RAP WHI CH IS P RO VIDE D BY THE INS TALL ER SHOU LD AL SO
B E PL AS TIC TO C OM PLETELY IS OL AT E TH E CO OLE R FR OM T HE B UILD ING P LUM BIN G SY S TE M.
MIN IMUM 40 P SI SU PP LY LINE P R ES S UR E RE QU IRE D IN S P EC IAL C IRC UM STA NC ES W HEN B OT H
S IDE S OF BIL EV EL AR E IN U SE S IMU LTANEOU S LY TO ENSU RE AD EQU ATE S TR E AM H EIG HT. DOE S
NO T A PP LY TO NON -R EF RIG E RATE D UNIT S.
1-1/2"
(38mm)
(459mm)
5-3/4"
(146mm)
5"
(127mm)
5-3/4"
(146mm)
1-3/8"
(35mm)
1-3/8"
(35mm)
C
L
3-1/2"
(89mm)
4-1/2"
(114mm)
5-3/4"
(146mm)
18-3/4"
(476mm)
B
13-7/8"
(351mm)
D
E
A
F
20-1/8"
(511mm)
(638mm)
HANGER BRACKET
39-1/2"
(1003mm)
ORIFICE
HEIGHT
25-1/8"
HEIGHT
32-15/16"
(837mm)
ORIFICE
HEIGHT
31-7/8"
(810mm)
*REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
2-5/8"
(67mm)
RIM
* "72
(686mm)
8"
(203mm)
C
4-3/4"
(121mm)
18-5/8"
(473mm)
12-5/16"
(313mm)
AU S E
ME ET S
6-3/4"
(173mm)
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
3” (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN.
C = 1- 1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UN
ADA REQUIREMENT
E lkay
12-57C
IT TO WALL.
2222 Camden Court
Oa k Brook, IL 60523
Printed in U.S .A.
© 2015 E lkay