EZH2O® Bottle Filling Station
with Single High-Efciency Cooler
SPECIFICATIONS
PRODUCT SPECIFICATION
Unit shall include high-efciency electric water cooler with bottle lling
station. VRCGRN8WSK shall deliver 8 GPH of 50°F drinking water at
90°F ambient and 80°F inlet water. Unit shall have Vandal-resistant
pushbutton activation with Vandal-resistant StreamSaver™ water
conservation bubbler. Bottle lling unit shall include an electronic sensor
for touchless activation with auto 20-second shut-off timer. Shall include
Green Ticker™ displaying count of plastic bottles saved from waste. Bottle
ller shall provide 1.1 gpm ow rate with laminar ow to minimize
splashing. Shall include integrated silver ion anti-microbial protection in
key areas. Unit shall meet ADA guidelines. Unit shall be lead-free design
which is certied to NSF/ANSI 61 and 372 and meets Federal and State
low-lead requirements. Unit shall be certied to UL399 and
CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Sanitary, touchless activation with auto 20-second shut-off (Bottle Filler)
• Vandal-resistant, easy to operate front pushbutton control (Cooler)
• Integrated Silver Ion Anti-microbial Protection in key areas
• Quick Fill Rate: 1.1 gpm
• Laminar Flow provides minimal splash
• Real Drain System eliminates standing water
• Visual User Interface display includes:
• Innovative Green Ticker™ counts bottles saved from waste
• Cooler panel nish: Stainless Steel
Model VRCGRN8WSK
RATED FOR INDOOR USE ONLY
Model
VRCGRN8WSK
COOLING SYSTEM
• High Efciency Compressor: hermetically-sealed, reciprocating type,
single phase. Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous
copper tubing with stainless steel tank. Fully insulated with EPS foam
which meets UL requirements for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat
is factory preset. Requires no adjustment other than for altitude
requirements.
CAPACITIES CHART
Model
VRCGRN8WSK 115V / 60Hz 8 GPH 3.8 260 89
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
Warranty: 5 year limited warranty on the unit’s refrigeration system.
Electrical components and water system are warranted for 12 months
from date of installation or 18 months from factory shipment, whichever
date falls rst.
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
Ship
Wt.
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides
structural integrity
• Stainless steel bottle ller wrapper with ABS plastic alcove
• Cooler cabinet is Stainless Steel construction
• Vandal-resistant StreamSaver™ water-efcient bubbler is
one-piece heavy-duty chrome-plated
CERTIFICATIONS / STANDARDS
• ADA Compliant
• UL399 and CAN/CSA 22.2 No. 120 Certied
• ANSI/NSF 61 and 372 Certied
• GreenSpec® Listed
This specication describes an Elkay product with design,
quality and functional benets to the user. When making a
comparison of other producer’s offerings, be certain these
features are not overlooked.
In keeping with our policy of continuing product
improvement, Elkay reserves the right to change
specication without notice. Please visit elkaypro.com
for the most current version.
2222 Camden Court
OakBrook, IL 60523
630-572-3192
elkay.com
© 2014 Elkay
SPEC14-65 (09/2014)
EZH2O® Bottle Filling Station
with Single High-Efciency Cooler
Model VRCGRN8WSK
ROUGH-IN
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
52 1/16"
1323mm
31"
787mm
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
TUBE IS SECURED
TUBE IS SECURED
B CA
7/16"
O
11mm
MOUNTING HOLES
(6)
5 3/4"
146mm
5/16" (8mm) DIA. (5 HOLES)
25"
635mm
21 3/8"
543mm
18 3/8"
467mm
IN POSITION
IN POSITION
1 3/8"
35mm
E
B
D
A
SERVICE STOP
(NOT FURNISHED)
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
7"
178mm
5"
127mm
BUILDING WATER
INLET
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
RELEASE TUBE
RELEASE TUBE
17 7/8"
454mm
7"
178mm
C
L
11/16"
18mm
2 1/2"
64mm
2 7/16"
63mm
3 1/2"
89mm
4 1/2"
114mm
10"
254mm
4 9/16"
116mm
F
13 7/8"
352mm
5 3/4"
146mm
1 3/8"
35mm
E
7 1/4"
185mm
2 9/16"
65mm
NOTICE
RATED FOR INDOOR USE ONLY
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non-metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not
been altered by materials in the cooler waterway. The grounding of electrical
equipment such as telephone, computers, etc. to water lines is a common
procedure. This grounding may be in the building but may also occur away from
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown).
Water and electrical will connect through pre-punched hole in basin.
3 9/16"
90mm
18 1/2"
HANGER BRACKET
C
6 1/4"
159mm
12 5/16"
313mm
471mm
1 1/2"
38mm
6 3/4"
172mm
15"
381mm
3 3/16"
82mm
FINISHED FLOOR
32 15/16"
837mm
ORIFICE
HEIGHT
2 5/8"
67mm
31 13/16"
808mm
RIM HEIGHT
27"
686mm
ADA
REQUIREMENT
18 7/8"
479mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).