VRCGRN8WS*1B VRCGRNTL8WS*1B
Installation/Care/Use Manual
VRCGRN8WS Factory Prep
EZH2O Bottle Filling St ation and Cooler
IMPORTANT
THIS IS AN INDOOR APPLICATION ONL Y .
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4” WRENCH OR CRECENT WRENCH
5/16” NUT DRIVER
UTILITY KNIFE
T APE MEASURE
PENCIL
CENTER PUNCH
1/2” SOCKET & RA TCHET WRENCH
5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE
BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER.
THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS
PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC T O ELECTRICALLY ISOLA TE THE FOUNT AIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THA T THE BOTTLE FILLING ST A TION AND W A TER
COOLER BE PROTECTED BY A GROUND F AUL T CIRCUIT INTERRUPTER (GFCI).
INSTALLER
VRCGRN8WS Bottle Fillers are among the easiest to install on the market today. To
insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.
Page 1 98769C (Rev. A - 6/11)
VRCGRN8WS*1B VRCGRNTL8WS*1B
19 1/16"
484mm
6 3/4"
1 1/2"
38mm
3 9/16"
90mm
18 5/8"
473mm
HANGER BRACKET
C
6 1/4"
158mm
8"
203mm
171mm
12 5/16"
313mm
VRCGRN8WS
15"
381mm
7"
178mm
17 7/8"
454mm
7"
178mm
OBROUND
7/16" X 3/4"
MOUNTING
HOLES (6 PL)
(11mm X 19mm)
27"
686mm
2 5/8"
66mm
RIM
31 13/16"
808mm
HEIGHT
ORIFICE
32 15/16"
837mm
7 1/4"
3 3/8"
86mm
1 3/8"
35mm
5 3/4"
146mm
C
5 3/4"
146mm
1 3/8"
35mm
HOLES (5 PL)
5/16"
8mm
O
E
4 9/16"
116mm
L
E
B
185mm
11/16"
18mm
2 1/2"
D
*
HEIGHT
2 9/16"
65mm
F
64mm
A
25"
635mm
30 15/16"
786mm
13 13/16"
351mm
4 1/2"
114mm
3 1/2"
89mm
2 7/16"
63mm
18 3/8"
467mm
21 3/8"
543mm
9 15/16"
252mm
FINISHED FLOOR
5"
127mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = RECOMMENDED W ATER SUPPL Y LOCA TION 3/8” O.D. UNPLA TED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF V AL VE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO W ALL.
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
51 9/16"
1310mm
Single Rough-In
Fig. 1
Page 298769C (Rev. A - 6/11)
VRCGRN8WS*1B VRCGRNTL8WS*1B
19 1/16"
484mm
6 3/4"
171mm
3 9/16"
90mm
18 5/8"
473mm
HANGER BRACKET
2 5/8"
66mm
39 7/16"
1002mm
ORIFICE
C
8"
203mm
32 15/16"
837mm
HEIGHT
4 1/8"
104mm
RIM
HEIGHT
31 13/16"
809mm
HEIGHT
ORIFICE
12 5/16"
313mm
27"
686mm
*
VRCGRNTL8WS
18 1/16"
459mm
15"
381mm
7"
178mm
17 7/8"
454mm
7"
178mm
OBROUND
7/16" X 3/4"
MOUNTING
HOLES (6 PL)
(11mm X 19mm)
25 1/8"
638mm
20 1/8"
511mm
18 3/4"
A
E
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
3 3/8"
86mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
HOLES (10 PL)
5/16"
8mm
O
4 9/16"
L
C
E
1 3/8"
35mm
6 1/2"
165mm
D
L
C
1 3/8"
35mm
11/16"
18mm
116mm
F
7 1/4"
185mm
F
2 7/16"
63mm
9 15/16"
252mm
5"
127mm
2 9/16"
65mm
37 7/16"
951mm
477mm
13 13/16"
351mm
3 1/2"
89mm
4 1/2"
114mm
6 1/4"
159mm
B
FINISHED FL OOR
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = RECOMMENDED W ATER SUPPL Y LOCA TION 3/8” O.D. UNPLA TED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF V AL VE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/2” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO W ALL.
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
20 5/16"
516mm
58 1/16"
1475mm
Two -Level Rough-In
Fig. 2
Page 3 98769C (Rev. A - 6/11)