MFWS200 / MFWS220 MOUNTING FRAME INSTRUCTIONS
MFWS220
OPTIONAL BRACKET
FOR ACCESS PANEL
5/16" SCREWS OR BOLTS
(20 REQ'D - NOT FURNISHED)
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19mm) BOLTS
(4 REQ'D - PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
OPTIONAL BRACKET
FOR ACCESS PANEL
FRAME
WOOD OR STEEL FRAME
SHOWN (NOT PROVIDED)
37 1/2"
952mm
OPTIONAL FOR
ACCESS PANEL
3"
76mm
3"
76mm
8 5/8"
219mm
OPTIONAL FOR
ACCESS PANEL
FLOOR LINE
10 1/4"
260mm
31 1/2"
800mm
25"
635mm
1. Cut a square rectangular wall opening 37 1/2” (953mm) W x 31 1/2” (800mm) H and 25” (635mm) above
the oor line. These dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI
standard A117.1.
2. Reinforce the wall opening on all sides so that it will adequately support the water fountain. This reinforcement
must support up to 150 lbs static load and provide a means for securing the frame assembly in place.
3. Install plumbing rough-ins.
4. Remove frame assembly and related hardware from packaging. Attach the two frames together thru the
upright supports with (4) 5/16” x 3/4” (19mm) long bolts and nuts (provided). Tighten securely.
5. Install the frame assembly squarely in wall opening with frame upright support edges ush with the nished
wall face. Secure the frame to the wall thru holes with (12) 5/16” bolts or screws (not provided). Tighten securely.
NOTE: Be sure that frame is squared in location. Do not use less than required screw quantity and size.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
0000000755 (Rev. B - 10/13)