No Lead Two-Level SwirlFlo
Filtered Wall Mount, Barrier-Free
Refrigerated Fountain with EZH2O® Bottle Filling Station
®
SPECIFICATIONS
PRODUCT SPECIFICATION
Architectural fountains with integral bottle lling station. LZWS-LRPBM28K shall deliver
8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. Units shall be
stainless steel construction with plastic ABS alcove. Sensor-activation with an auto
20-second shut-off timer. Shall include Green Ticker™ displaying count of plastic bottles
saved from waste. Bottle ller shall provide 1.1 gpm ow rate with laminar ow to
minimize splashing. Shall include the Water Sentry® Plus 3000-gallon capacity lter,
certied to NSF/ANSI 42 and 53, with visual monitor to indicate when replacement
is necessary. Shall include integrated silver ion anti-microbial protection in key areas.
Unit shall meet ADA guidelines. Unit shall be lead-free design which is certied to
NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall
be certied to UL399 and CAN/CSA 22.2 No. 120.
FOUNTAINS GENERAL
Fully exposed two-level fountain basins are #18 gauge, 300 series stainless steel
polished to a lustrous satin nish with high shine outer edge. #16 gauge, 300 series
tubular stainless steel support arms incorporate unique recess to be integrated with
basin. One fountain positioned lower on the right for wheel-chair use. The other
positioned on the left at standing height.
Fountains have contoured basin that minimizes splashing. Flexi-Guard® Safety
bubblers are keyed in location to prevent rotation. Fully functional, vandal-resistant front
push button. Flow regulator provides constant stream from 20 to 105 psi water pressure.
BOTTLE FILLER STANDARD FEATURES
• Sanitary, touchless activation with auto 20-second shut-off (Bottle Filler)
• WaterSentry®Plus 3000-gallon capacity Filtration System, certied to
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & odor)
• Integrated Silver Ion Anti-microbial Protection in key areas
• Quick Fill Rate: 1.1 gpm
• Laminar Flow provides minimal splash
• Real Drain System eliminates standing water
• Visual User Interface display includes:
• Innovative Green Ticker™ counts bottles saved from waste
• LED Visual Filter Monitor shows when replacement is necessary
• Includes lower panel for easy access and servicing
OPTIONAL FEATURES (Additional Cost)
• For front access to bottle ller electricals, use access panel
Item #ACCESS12X38-5)
COOLING SYSTEM
• Compressor: Hermetically-sealed, reciprocating type, single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled. Fan motor is permanently lubricated.
• Cooling Unit: Combination tube-tank type. Continuous copper tubing with
stainless steel tank. Fully insulated with EPS foam which meets UL
requirements for self-extinguishing material.
• Refrigerant control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Enclosed adjustable thermostat is factory preset.
Requires no adjustment other than for altitude requirements, easily
accessible by removing lower grille panel.
CAPACITIES CHART
Shown with one optional
access panel installed
Model LZWS-LRPBM28K
Rated for Indoor Use Only
Model
LZWS-LRPBM28K
CONSTRUCTION
LZWS-LRPBM28K two-level fountain furnished complete withFlexi-Guard® fully
assembled with front push button, ow regulator (120 to 105 psi), stainless steel
back panel and surface mounting plate. No traps are furnished.
• Stainless Steel bottle ller construction with ABS plastic alcove
• Includes stainless steel lower panel
• Furnished with wall mounting frame constructed of galvanized steel
• Mounting can be ordered separately for pre-install
Replacement Filters: Available as Singles and Multi-packs. Order part
numbers:
• 51300C (single)
• 51300C_3PK (three)
• 51300C_12PK (twelve)
• 51300C_24PK (twenty-four)
• 51300C_48PK (forty-eight)
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical
components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever date falls rst.
CERTIFICATIONS / STANDARDS
• ADA Compliant
• UL399 and CAN/CSA 22.2 No. 120 Certied
• NSF/ANSI 42 and 53 Certied (Filter Only)
• NSF/ANSI 61 and 372 Certied
• GreenSpec Listed
Model
LZWS-LRPBM28K 115V / 60Hz 8 GPH 5.0 370 173
In keeping with our policy of continuing product
improvement, Elkay reserves the right to change specication
without notice. Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling
Capacity
F.L.
Amps
Rated
Watts
Approx. Ship
Wt.
2222 Camden Court
OakBrook, IL 60523
630-572-3192
elkay.com
This specication describes an Elkay product with design, quality and functional
benets to the user. When making a comparison of other producer’s offerings, be
certain these features are not overlooked.
© 2015 Elkay
SPEC00048 (02/2015)
No Lead Two-Level SwirlFlo
®
Filtered Wall Mount, Barrier-Free
Refrigerated Fountain with EZH2O® Bottle Filling Station
Model LZWS-LRPBM28K
INSTALLER NOTE:
THIS DRINKING FOUNTAIN IS FURNISHED
WITH A BUBBLER AND VALVE INCLUDING
ALL CONNECTING FITTINGS WHICH ARE
MANUFACTURED OF COMPLETELY LEAD
FREE MATERIAL. SHUTOFF VALVE (NOT
FURNISHED) TO ACCEPT 3/8” O.D. UNPLATED COPPER TUBE.
WALL OPENING
IMPORTANT: It is necessary to create a wall
opening 37 ½” W x 52 ⅛” H and 4 ½” above
the oor line.
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch
circuit. Standard 120 Volt, 60 Hz, single phase.
Electrical outlet, three (3) conductor grounded.
Locate within safe reach of power cord.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and
electrical sources. The support frame is to be
installed rst. Hang upper panel to hanger on
frame. Fountains are to be attached to panel
and wall frame. Water service lines, waste lines
and electrical are assembled as required. Perform a nal check for leaks and correct functions
of fountains and chiller. (For details see the
installation instructions.)
Installation requires trap to be installed in
wall. Trap and service stop not included.
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
WALL LAYOUT
OPTIONAL BRACKET
FOR ACCESS PANEL
5/16" SCREWS OR BOLTS
(20 REQ'D - NOT FURNISHED)
FRAME
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19m) BOLTS
(4 REQ'D-PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
ROUGH-IN DIMENSIONS
1/4” O.D. TUBE
WATER INLET
TO COOLER
P/N 101567443730
HOOK RODS (2)
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
37 1/2"
952mm
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
3"
76mm
10 1/4"
260mm
OPTIONAL FOR
ACCESS PANEL
52 1/8"
1324mm
4 1/2"
114mm
SPEC00048 (02/2015)
34 5/8"
879mm
20 7/16"
519mm
FRONT VIEW
9 7/8"
251mm
FINISHED FLOOR
38 1/2"
978mm
18 11/16"
474mm
ACTIVATION
SENSOR
44 3/4"
1137mm
41 11/16"
1059mm
1 5/8"
41mm
33 15/16"
862mm
1 5/8"
41mm
27"
686mm
ADA
REQUIREMENT
2222 Camden Court
Oak Brook, IL 60523
SIDE VIEW
18 3/8"
467mm
5/8"
16mm
3/8" O.D. COPPER TUBE
WATER INLET ON
CHILLER. SHUT OFF
VALVE BY OTHERS
ELECTRICAL
INLET
11"
279mm
1 1/8"
29mm
12"
305mm
SPACE REQ'D
BEHIND STUD WALL
BOTTLE FILLER
DRAIN
1-1/4" (32mm)
WASTE TUBES
FURNISHED
1/4" O.D. COPPER
TUBE. COLD WATER
OUTLET
8"
203mm
4 1/2"
114mm
28 3/4"
730mm
36 1/2"
927mm
Printed in U.S.A.
© 2015 Elkay