Versatile Bi-Level Wall Mounted Water Cooler
Filtered, Pushbar Activated
PRODUCT SPECIFICATION
Self-contained wall mount electric two-level water cooler. Refrigerated LZ(S)TL8
models offer a chilling capacity of 8 GPH of 50°F drinking water, based upon 80°F
inlet water and 90°F ambient. Models LZSTLDD is non-refrigerated shall deliver
non-chilled drinking water. Shall include the WaterSentry® VII 1500-gallon capacity
lter, certied to NSF/ANSI 42 and 53. Unit shall meet ADA guidelines. Unit shall be
lead-free design which is certied to NSF/ANSI 61 and 372 and meets Federal
and State low-lead requirements. Unit shall be certied to UL399 and
CAN/CSA 22.2 No. 120.
Models LZSTL have self-closing Easy-Touch pushbar controls on front & sides.
Models LZTL have self-closing Easy-Touch pushbar controls on front only.
Models LZSTLDD are non-refrigerated. Requires outlet for power cord.
NOTE: Minimum 40 psi supply line pressure required in special circumstances where
both sides of bi-level are in use simultaneously to ensure adequate stream height.
STANDARD FEATURES
• Easy-Touch pushbar activation
• WaterSentry® VII 1500-gallon capacity Filtration System, certied to
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
• Extra deep basin minimizes splashing; with integral drain
• Available with Flexi-Guard® Safety bubbler or Vandal-resistantt bubbler
Vandal-resistantt bubbler (tincludes “VR” code in model no.)
• Valve with built-in ow regulator to provide constant stream from 20 to 105 psi
water pressure
• *Versatile cooler design allows units to be installed either left-hand high and
right-hand low or left-low and right high
• Cooler panel nishes: Light Gray Granite Vinyl Clad Steel or Stainless Steel
• Rated for Indoor Use
COOLING SYSTEM (Models LZ(S)TL(VR)8 only)
• Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in
lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Tube type. Self-cleansing. Continuous Copper tubing which is fully
insulated with EPS foam that meets UL requirements for self-extinguishing
material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated
capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude requirements.
Models LZ(S)TL8 and LZSTLDD
RATED FOR INDOOR USE ONLY
*Versatile cooler conguration
as shipped
*Versatile cooler conguration
alternate installation
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides structural
integrity
• Cooler cabinet available as Light Gray Granite Vinyl Clad Steel
or Stainless Steel (additional cost) construction
• Exclusive Flexi-Guard® Safety bubbler (option) utilizes an infused
anti-microbial pliable polyester elastomer to prevent accidental
mouth injuries. Flexes on impact.
• Vandal-resistantt bubbler (option) is one-piece heavy duty
REPLACEMENT FILTER:
• 51299C (single)
Warranty: 5 year limited warranty on the unit’s refrigeration system.
Electrical components and water system are warranted for 12
months from date of installation or 18 months from factory shipment,
whichever date falls rst.
CAPACITIES CHART
Model
LZ(S)TL(VR)8*C 115V / 60Hz 8 GPH 4.0 370 75 lbs
LZ(S)TL(VR)8*2JOC 220V / 50Hz 6.7 GPH 2.5 370 75 lbs
LZ(S)TL(VR)8*3JOC 220V / 60Hz 8 GPH 2.5 370 75 lbs
LZSTL(VR)DD*C 115V / 60Hz – 1.0 15 49 lbs
*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels.
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice.
Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Rated
Watts
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
Approx.
Ship
elkay.com
ANSI/NSF
42 and 53
Wt.
UL399 and
CAN/CSA 22.2
No. 120
Certied
ADA
Compliant
ANSI/NSF
61 and 372
Certied
• • • •
++ • • •
++ • • •
• • • •
This specication describes an Elkay product with design, quality and functional
benets to the user. When making a comparison of other producer’s offerings,
be certain these features are not overlooked.
SPEC08-19 (06/2014)
© 2014 Elkay
Certied
(Filter
only)
Versatile Bi-Level Wall Mounted Water Cooler
Filtered, Pushbar Activated
Models LZ(S)TL8 and LZSTLDD
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not
been altered by materials in the cooler waterway. The grounding of electrical
equipment such as telephone, computers, etc. to water lines is a common
procedure. This grounding may be in the building but may also occur away from
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
Model shown with Flexi-Guard® bubbler.
ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS
18 3/8"
2"
51mm
34 5/16"
872mm
9/32"
7mm
(ALT. LOCATION)
24 1/2"
622mm
22 15/16"
583mm
DIA. ((12)
FILTER
A
E
F
19 7/16"
494mm
D
PREFFERED
LOCATION
6 3/8"
162mm
467mm
‰
17 7/16"
443mm
6 3/8"
162mm
2"
51mm
7/8"
22mm
13 15/16"
354mm
18 3/8"
467mm
6 3/8"
162mm
‰
B
F
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
FINISHED FLOOR
6 3/8"
162mm
PREFFERED
LOCATION
2"
51mm
7"
178mm
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
NOTICE
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non-metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
19"
483mm
HANGER
BRACKET
2"
51mm
38 3/8"
975mm
ORIFICE
A
19"
483mm
E
21 7/8"
556mm
28 13/16"
732mm
HEIGHT
36 13/16"
936mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE
HEIGHT
31 5/16"
796mm
RIM
HEIGHT
27"
686mm
ADA
REQUIREMENT
8 1/16"
205mm
FILTER
12 1/2"
318mm
C
1 7/16"
37mm
3"
76mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
2222 Camden Court
Page 2
Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in U.S.A.
© 2014 Elkay