SPECIFICATIONS
High-Efficiency GreenSpec® Listed
Single Filtered Water Cooler
Models LZSG8
PRODUCT SPECIFICATION
High-efficiency electric, refrigerated water cooler. Model LZSG8 shall
deliver 8 GPH of 50
water. Unit shall meet ADA guidelines. Shall include the WaterSentry
1500-gallon capacity filter, certified to NSF/ANSI 42 and 53. Unit shall be
lead-free design which is certified to NSF/ANSI 61 and 372 and meets
Federal and State low-lead requirements. Unit shall be certified to UL399
and CAN/CSA 22.2 No. 120. Unit shall be GreenSpec® Listed.
.
o
F drinking water at 90o F ambient and 80o F inlet
®
VII
STANDARD FEATURES
Energy efficiency performance exceeds average market performance
by 35%
W aterSentry
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
Easy-touch front and side pushbar controls
F lexi-Guard
Cooler panel finishes: Light Gray Granite or Stainless Steel
®
VII 1500-gallon capacity Filtration System, certified to
®
StreamSaver™ water conservation bubbler
COOLING SYSTEM
High-efficiency Compressor: hermetically-sealed, reciprocating type,
single phase. Sealed-in lifetime lubrication.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is
permanently lubricated.
Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous
copper tubing with stainless steel tank. Fully insulated with EPS foam
which meets UL requirements for self-extinguishing material.
Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
Temperature Control: Easily accessible enclosed adjustable thermostat
is factory preset. Requires no adjustment other than for altitude
requirements,
CAPACITIES CHART
Model
LZSG8* 115V / 60Hz 8 GPH 3.2 360 68
*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels
**Based on 80
Voltage /
Hertz
o
F inlet water & 90oF ambient air temp for 50oF chilled drinking water.
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
Ship
Wt.
RATED FOR INDOOR USE ONLY
CONSTRUCTION
Stainless Steel basin with integral drain
Galvanized structural steel cooler chassis
provides structural integrity
Cooler cabinet available as Light Gray Granite
Vinyl Clad Steel or Stainless Steel (additional
cost) construction.
F lexi-Guard
utilizes an infused anti-microbial pliable
polyester elastomer to prevent accidental mouth
injuries. Flexes on impact. Lower-flow waterefficient water stream.
Replacement Filter: 51299C
Warranty: 5 year limited warranty on the unit’s
refrigeration system. Electrical components and
water system are warranted for 12 months from
date of installation or 18 months from factory
shipment, whichever date falls first.
CERTIFICATIONS / STANDARDS
ADA Compliant
UL399 and CAN/CSA 22.2 No. 120 Certified
ANSI/NSF 61 and 372 Certified
ANSI/NSF 42 and 53 Certified
GreenSp ec
®
StreamSaver™ Safety Bubbler
®
Listed
(Filter only)
In keeping with our policy of continuing product
improvement, Elkay reserves the right to change
specifications without notice. Please visit elkayusa.com
for the most current version.
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
Elkayusa.com
This specification describes an Elkay product with design,
quality and functional benefits to the user. When making a
comparison of other producer’s offerings, be certain these
features are not overlooked.
© 2013 Elkay
SPEC00096 (Rev 06/2013)
High-Efficiency, GreenSpec Listed
®
Single Filtered Water Cooler
Models LZSG8
ROUGH-IN
IMPORTANT!
INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the
user which has not been altered by materials in the cooler
waterway. The grounding of electrical equipment such as
telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause
electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by
installing the cooler using the proper materials as shown.
NOTICE
This water cooler must be connected to the water supply
using a dielectric coupling. The cooler is furnished with a nonmetallic strainer which meets this requirement. The drain trap
which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system
18 3/8"
467mm
6 3/8"
162mm
9/32"
7mm
O HOLES (6)
6 3/8"
162mm
2"
51mm
1/4” O.D. TUBE
WATER INLET
TO COOLER
*Rated for indoor use only
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
19"
483mm
HANGER BRACKET
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
B
21 7/8"
556mm
19"
483mm
E
D
17 7/16"
443mm
C
L
2"
F
7"
178mm
51mm
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
E
A
28 13/16"
13 15/16"
354mm
732mm
FINISHED FLOOR
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8 O.D. unplated copper tube. 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” out from wall.
C = 1-1/4” Trap (not furnished)
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from
cabinet louvers to wall.
F = 7/16” Bolt Holes for fastening to wall.
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
Elkay
SPEC00096 (06/2013)
2222 Camden Court
Oak Brook, IL 60523 USA
elkayusa.com
32 7/8"
835mm
ORIFICE
HEIGHT
31 5/16"
796mm
RIM HEIGHT
686mm
27"
8 1/16"
205mm
12 1/2"
318mm
C
76mm
5 7/8"
150mm
3"
Job Name: _______________________________________
Date: ____________________ Qty: __________________
Contact Info (Name, Phone, Email): ____________________
_________________________________________________
_________________________________________________
Approval: _________________________________________
© 2013 Elkay
2"
51mm
Page 2