Elkay LZS8S2QJO User Manual

Filtered
Wall Mount Water Cooler
SPECIFICATIONS
PRODUCT SPECIFICATION
Self-contained, wall mount single electric water cooler. Refrigerated LZS8S2QJO model offers a chilling capacity of 8 gallons per hour of 50°F drinking water, based upon 80°F inlet water and 90°F ambient. Shall iinclude the WaterSentry® VII 1500-gallon capacity lter, certied to NSF/ANSI 42 and 53. Unit shall meet ADA guidelines. Unit shall be
lead-free design which is certied to NSF/ANSI 61 and 372 and meets
Federal and State low-lead requirements.
STANDARD FEATURES
• Easy-Touch pushbar activation
• WaterSentry® VII 1500-gallon capacity Filtration System, certied to
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
• Extra deep basin minimizes splashing; with integral drain
• Exclusive Flexi-Guard® Safety bubbler
• Valve with built-in ow regulator to provide constant stream from 20 to 105
psi water pressure
• Finish option: Stainless steel wrapper
• Rated for Indoor use
COOLING SYSTEM
• Compressor: Hermetically-sealed, reciprocating type, single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Tube type. Self-cleansing. Continuous copper tubing which
is fully insulated with EPS foam that meets UL requirements for
self-extinguishing material
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
RATED FOR INDOOR USE ONLY
ONLY AVAILABE FOR QATAR
CONSTRUCTION
Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides structural
integrity
Cooler cabinet is Stainless Steel construction
• Exclusive Flexi-Guard® Safety Bubbler utilizes an infused anti-microbia
pliable polyester elastomer to prevent accidental mouth injuries. Flexes
on impact.
REPLACEMENT FILTER:
51299C
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment,
whichever date falls rst.
CAPACITIES CHART
Model
LZS8S2QJO 240V / 50Hz 6.7 GPH 2.0 370 54 lbs
` **Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
2222 Camden Court
Oak Brook, IL 60523
Rated
Watts
630-572-3192
elkay.com
Approx.
Ship
Wt.
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer ’s offerings, be certain these features are not overlooked.
ADA
COMPLIANT
NSF/ANSI
61 and 372
Certied
NSF/ANSI 42 and 53
Certied
(Filter only)
© 2015 Elkay
SPEC00331 (03/2015)
Filtered
Open space rough-in design permits new installation or replacement of existing
creating an electrolysis which creates a metallic taste or causes an increase in the
Wall Mount Water Cooler Models LZS8S2QJO
fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electrical feedback into a water cooler
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
18 3/8"
467mm
6 3/8"
162mm
2"
51mm
E
A
9/32" 7mm
O
FILTER
6 3/8"
(6)
162mm
B
E
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
ONLY AVAILABE FOR QATAR
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap, which is provided by the installer, should also be plastic to completely
isolate the cooler from the building plumbing system.
32 7/8"
835mm
ORIFICE
HEIGHT
NOTICE
8 1/16"
205mm
19"
483mm
HANGER BRACKET
21 7/8"
556mm
19"
483mm
17 7/16"
443mm
F
7"
178mm
2"
51mm
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
13 15/16" 354mm
FINISHED FLOOR
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
LEGEND: A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
D
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
28 13/16"
732mm
31 5/16" 796mm
RIM
HEIGHT
27"
686mm
ADA
REQUIREMENT
C
FILTER
12 1/2"
318mm
5 7/8"
150mm
77mm
3"
51mm
2"
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2015 Elkay