Elkay LZO Series, LZO8L, LZOTL Series, LZOTL8 Installation, Care & Use Manual

Page 1
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
INSTALLATION, CARE & USE MANUAL
LZO™ Series Sensor-Operated Water Coolers
Model LZO8L
Page 1
1000003094 (Rev. B - 11/16)
Page 2
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
Note: Danger! Electrical shock hazard. Disconnect power before servicing unit.
Uses HFC-134A refrigerant
7
See Fig. 4
2
1
4
8
6
Sensor Eye Adjustment screw
See Fig. 5
3
See Note 8
Stream Height
Adjustment Screw
1000003094 (Rev. D - 11/16)
8
9
5
FIG. 1
Page 2
Page 3
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
5
2"
51mm
3"
19"
484mm
HANGER BRACKET
C
FILTER
8 1/16"
205mm
27"
ADA
686mm
77mm
5 7/8"
150mm
12 1/2"
318mm
REQUIREMENT
RIM
HEIGHT
31 5/16"
796mm
HEIGHT
32 7/8"
ORIFICE
835mm
2"
51mm
A
E
6 3/8"
162mm
732mm
28 13/16"
354mm
13 15/16"
2"
3 7/8"
51mm
7"
5 3/4"
98mm
146mm
178mm
18 3/8"
467mm
6 3/8"
162mm
F
D
B
(6)
O
9/32"
7mm
E
17 7/16"
FILTER
443mm
19"
483mm
FINISHED FLOOR
7"
178mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER
56mm
21 7/8"
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4” DE SORTIE D’EAU. STUB 2 HORS DU MUR
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)
**LAS NUEVAS INSTALACIONES DEBEN UTILIZAR LOS INTERRUPTORES DE CIRCUITO DE TIERRA DE LA AVERÍA (GFCI)
**LES NOUVELLES INSTALLATIONS DOIVENT EMPLOYER LES INTERRUPTEURS DE CIRCUIT MOULUS DE DÉFAUT (GFCI)
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3” IN. (76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN STUB 2” OUT FROM WALL
C = 1-1/4” TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
FIG. 2
Page 3
1000003094 (Rev. B - 11/16)
F = 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL
Page 4
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
HANGER BRACKETS & TRAP
1) Remove hanger bracket fastened to back of cooler by removing one (1) screw.
2) Mount the hanger bracket as shown in Figure 2.
NOTE: Hanger Bracket MUST be supported securely. Add xture support carrier if wall will not provide adequate support. Anchor hanger
securely to wall using all six (6) 1/4 in. dia. mounting holes.
IMPORTANT:
5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper t.
3) Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 2.
4) Remove the four (4) screws holding the lower front panel at the bottom of cooler. Remove the front panel by pulling straight down and set aside.
5) Connect water inlet line--See Note 4 of General Instructions.
6) Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the
waste line ts into the trap. Assemble the slip nut and gasket to the trap and tighten securely.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
7) Plug in electrical power. Unit must have
electrical power to have water ow.
8) Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust screw located on the left side below the push bar assembly on the crossbar. CW adjustment will raise stream and CCW adjustment will lower stream. For best
adjustment, stream should hit basin approximately 6-1/2” (165mm) from bubbler on the downward slope of the basin. NOTE: If continuous ow occurs at the end of the compressor cycle, turn cold control counterclockwise 1/4 turn.
9) Replace the front panel ensuring that the metal wrapper is secured inside of the upper shroud. Replace all four screws previously removed.
INSTALLATION
INSTALLATION OF COOLER
START UP
Also See General Instructions
SENSOR RANGE ADJUSTMENT:
The electronic sensor used in this cooler is factory pre-set for a “visual” range of 36 inches (914 mm). If actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure below:
- Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses (See Page 1.) Turn this screw clockwise to increase range and counterclockwise to decrease range (See Fig. 3). CAUTION: Complete range of sensor (24-36 inches/610-1168mm) is only one turn of the adjusting screw.
SENSOR WITH VISUAL FILTER MONITOR (VFM) – LZO SERIES:
The electronic sensor includes LED lter status indicators that are factory preset to monitor lter life. The sensor monitors the “ON”
time of the water valve solenoid and keeps track of total time water is dispensed. There are (3) LED’s and indicates the following: Green LED (Good) indicates that the lter is operating within 0% - 80% of its life. Yellow LED indicates that the lter is operating within 80% - 100% of its life. Red LED (Replace) indicates that the lter needs to be replaced since it has reached end of lter life.
Once power is applied to the water cooler, if all three LED’s ash then the Green LED illuminates, this indicates that there is some lter usage memory stored. When the Green LED comes on only, this indicates that the lter life is at absolute 0% of lter life. NOTE: You may have some very minimal lter life in memory upon receiving water cooler due to factory functional testing.
NOTE: The lter status will be retained until reset (see resetting lter monitor). The lter monitor will retain its memory even
during a loss of power.
RESETTING VISUAL FILTER MONITOR (VFM):
In order to reset the visual lter monitor status LED’s, you must remove the access panel (item 13) underneath the front dispenser. With your nger or straight blade screw driver, reach inside opening and depress the reset button located on the back of the sensor for a minimum of 1 second. (You may need a ashlight) Reinstall access panel and the Green LED should be illuminated indicating that the visual lter monitor has been reset.
SENSOR CONTROL: If sensor fails to operate valve mechanism or operates erratically, check the following. A. Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler. B. Check wire connections at the solenoid valve and sensor. CAUTION: Make sure unit is unplugged before checking any wiring.
C. Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water ows, look for an obstruction in the
valve itself or elsewhere in the water supply line.
1000003094 (Rev. D - 11/16)
Page 4
Page 5
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
Bubbler
To remove the bubbler, rst disconnect the power supply. The underside of the bubbler can be
reached through the access panel (Item 13) on the underside of the upper shroud (Item 2). Remove the access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the
underside of the bubbler and remove the tubing from the quick connect tting per the Operation Of
Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.
NOTE:
When installing replacement bubbler and pedestal, tighten nut (Item 11) only to hold parts snug in position. Do Not Overtighten.
Cleaning the strainer
To clean the strainer, unscrew the cap of the solenoid valve. Remove screen and rinse thoroughly with water. Insert screen back into solenoid valve and screw cap on. Make sure the o-ring is placed properly.
11 - Bubbler
Assembly
3
11
2
6
FIG. 3
CLEANING
Warm, soapy water or mild household cleaning products can be used to clean the
exterior panels of the EZ coolers. Extra caution should be used to clean the mirror nished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex glass cleaner and a clean, soft cloth
Use of harsh chemicals or petroleum based or abrasive cleaners will void the
warranty.
8
Sensor Eye Adjustment Screw
11
8
FIG. 4
Basin
Page 5
BUBBLER DETAIL
FIG. 5
Locknut
1000003094 (Rev. B - 11/16)
Page 6
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
3
2
2
1
Fig. 6
WATERSENTRY® FILTER PARTS LIST
ITEM NO. PART NO.
1 2
3
1000003094 (Rev. D - 11/16)
WATERSENTRY® Filter Detail
Detalle WATERSENTRY® Filtro
Description WATERSENTRY® Filtrage
LISTA DE PIEZAS DEL FILTRO
(Vea la Fig. 6)
DESCRIPCIÓN DESCRIPTION
Ensamblado del Filtro-1500 Galón Montaje Cabeza Kit Filtro-Incluye John Guest Montaje y 3/8” Codo
Conjunto del Filtro y Soporte, Incluye Filtro Soporte/John Guest Guarniciones/ Tornillos de Montaje de Cabeza
Page 6
51299C 98926C
0000000746
(See Fig. 6)
DESCRIPTION
Filter Assy-1500 Gal. Kit-Filter Head Fitting Includes John Guest Fitting & 3/8” Elbow Fitting Assy-Filter & Bracket includes Fltr Head/Mtg Bkt/ John Guest Ftgs/Screws
LISTE DES PIÈCES DU
FILTRE (Voir Fig. 6)
Ens. ltre-1500 Gallon
Raccord Tête de Filtre Kit-InclutJohn Guest Montage et 3/8” Raccord en Coude Assemblêe-Filtre et Support Inclut Filtre/Montage Support/John Guest/ Vis à Têtê
Page 7
LZO8*1G LZO8*2G LZO8*3G LZOD*1D
115V PARTS LIST
ITEM
NO.
1 2 3 4 *5 6
7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
NS
PART
NO.
98724C 97970C
55001109
28401C 36322C 36263C 36266C 30873C 98898C 36285C 31376C 40322C 56073C 56092C 56213C 56228C 66703C 75710C
0000000238
98169C 98466C 98773C 98775C 98776C 98777C 98778C 98897C
98898C 1000000888 1000000944
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders
for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
Kit - Drain Replacement (EZ)(Brkt/Tube/Ftg/Clamp)
Sensor Assy - (Less Refrig. Unit)(Sensor/Fitting/Pin Terminal)
Kit - Fan Motor Assy/Blade/Motor/Shroud/Screws/Nut
Kit - Compr Mtg Hdwe/Grommets/Clips/Studs
Kit - EZTL Wrapper/Serv Label - Stainless (R)
Kit - EZTL Wrapper/Serv Label - Light Grey (R)
DESCRIPTION
Kit - Evaporator Replacement Assy.
Basin - Stainless Steel
Hanger Bracket
Compressor Serv. Pack
Sensor - VFM
Wire - Jumper
Kit - Hardware (EZ) for Panels
Power Cord (Refrig. Unit)
Power Cord (Less Refrig. Unit)
Orice Assy.
Kit - Bubbler Assy/Nut
Poly Tubing (Cut to Length)
Panel - Access
Upper Shroud Assembly
2-28 x .250 48-2 Plastite Screw
Kit - Compr Elect Relay/Overload/Cover
Kit - Replacement Cap/Screen/O-Ring
Kit - Solenoid Vlv/Regulator/Nut Assy.
Kit - LZO Pushbar Front/Side
Kit - Hardware (EZ) for Panels
Drier
Kit - Cold Control/Screws
Kit - Condenser/Drier
Kit - Heatx/Drier
COMPRESSOR
WIRING DIAGRAM - LZO 115V
WHT
OVERLOAD
3
1
2
C
6
3
RELAY
M
5
2
1
FAN
MALE TERMINAL ON WHITE SHORT LEAD ON POWERCORD
S
FIG. 7
BLK
RED
SOLENOID
COLD CONTROL
WHT
SENSOR
VALVE
BLK
GND
RED
WHITE
BLACK
GREEN
YELLOW PURPLE
GREEN
LED PCB
GND
7
ITEM
NO.
*5
9
17
19 21
28 NS NS
PART
NO.
1000002147 1000002146
36066C 98751C
98752C 0000000802 0000000245
33133000
28030C
35826C
220V PARTS LIST
DESCRIPTION
Compressor Serv. Pak (220V/50Hz) Compressor Serv. Pak (220V/60Hz)
Kit - Overload/Relay/Cvr (220V/50Hz) Kit - Overload/Relay/Cvr (220V/60Hz)
Kit - Solenoid Valve/Reg./Nut Assy. (220V/60Hz)
Kit - Fan Motor/Blade (220V 50Hz-60Hz)
Power Cord
Adapt - Tab .250 Brkt - Power Inlet
Inlet Power
COMPRESSOR
RELAY
WIRING DIAGRAM - LZO 230V
OVERLOAD
3
1
2
C
S
M
6
5
3
2
1
TO "L" TERMINAL ON POWER INLET
FAN
TO "GROUND" TERMINAL ON POWER INLET
WHT
BLK
RED
SOLENOID
COLD CONTROL
WHT
RED
WHITE
SENSOR
VALVE
MALE TERMINAL ON WHITE SHORT LEAD ON POWERCORD
GND
BLK
TO "N" TERMINAL ON POWER INLET
BLACK
GREEN
YELLOW PURPLE
GREEN
LED PCB
GND
7
PRINTED IN U.S.A.
IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U.
FIG. 8
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
Page 7
1000003094 (Rev. B - 11/16)