Elkay LZO8TL-3C Installation Manual

LZO8TL*1C, LZO8TL*2C, LZO8TL*3C
INSTALLATION, CARE & USE MANUAL
TM
LZOTL Series Barrier-Free Water Coolers
51
36
8
9
Uses HFC-134A
refrigerant
44
19
3435
48
5
See FIG. 3
39
Sensor Eye
Adjustment screw
6
44
18
13
16, 17
46
See FIG. 4
37
12
33
23
24
38
21
FIG. 1
Page 1
15
31, 32, 43
7
25
20
26
30
27, 28, 29
98399C (Rev. C - 03/09)
LZO8TL*1C, LZO8TL*2C, LZO8TL*3C
19"
483mm
8 1/16"
204mm
1 7/16"
37mm
12 1/2"
318mm
27"
686mm
ADA
REQUIREMENT
32 7/8"
835mm
ORIFICE
HEIGHT
38 3/8"
975mm
ORIFICE
HEIGHT
31 5/16"
796mm
RIM
HEIGHT
3"
76mm
C
HANGER
BRACKET
*
*
*
*
*
*ADA REQUIREMENT
*REQUISITO DE A.D.A.
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
*EXIGENCE ADA
18 3/8"
467mm
18 3/8"
467mm
98399C (Rev. C - 03/09)
9/32"
(6)
7mm
O
28 13/16"
732mm
2"
51mm
E
B
A (PREFERRED
LOCATION)
*
13 15/16"
354mm
*
FIG. 2
2"
LOCATION)
D (PREFERRED
22 15/16"
583mm
*
Page 2
51mm
3 7/8"
F
D (ALT. LOCATION)
21 7/8"
556mm
*
*
6 3/8"
162mm
6 3/8"
162mm
7/8"
22mm
2"
6 3/8"
162mm
6 3/8"
162mm
2"
51mm
51mm
E
A (ALT. LOCATION)
F
24 1/2"
622mm
34 5/16"
872mm
*
98mm
19"
7"
178mm
5 3/4"
146mm
7"
178mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLA TION OF CHILDRENS A D A COOLER
*
17 7/16"
443mm
*
483mm
*
FUERA DE PARED
HORS DU MUR
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU. STUB 2 HORS DU MUR
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/4 TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL