LZO8*1F LZO8*2F LZO8*3F
INSTALLATION, CARE & USE MANUAL
LZO Series Barrier-Free Water Coolers
TM
Model LZO8L
Page 1
0000000766 (Rev. B - 01/15)
Uses HFC-134A
refrigerant
LZO8*1F LZO8*2F LZO8*3F
19
See FIG. 4
2
24
1
4
21
7
12
8
13
6
25
Sensor Eye
Adjustment screw
See FIG. 5
3
0000000766 (Rev. B - 01/15)
25
20
8
25
22
15
9
5
17
23
FIG. 1
Page 2
LZO8*1F LZO8*2F LZO8*3F
2"
51mm
3"
19"
484mm
HANGER BRACKET
C
FILTER
8 1/16"
205mm
27"
ADA
686mm
77mm
5 7/8"
150mm
12 1/2"
318mm
REQUIREMENT
RIM
HEIGHT
31 5/16"
796mm
HEIGHT
32 7/8"
ORIFICE
835mm
2"
51mm
A
E
6 3/8"
162mm
732mm
28 13/16"
354mm
13 15/16"
2"
3 7/8"
51mm
7"
5 3/4"
98mm
146mm
178mm
‰
18 3/8"
467mm
6 3/8"
162mm
F
D
B
(6)
O
9/32"
7mm
E
17 7/16"
FILTER
443mm
19"
483mm
FINISHED FLOOR
7"
178mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
21 7/8"
556mm
FIG. 2
Page 3
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4” DE SORTIE D’EAU. STUB 2 HORS DU MUR
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3” IN. (76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN STUB 2” OUT FROM WALL
C = 1-1/4” TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL
0000000766 (Rev. B - 01/15)
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)
**LAS NUEVAS INSTALACIONES DEBEN UTILIZAR LOS INTERRUPTORES DE CIRCUITO DE TIERRA DE LA AVERÍA (GFCI)
**LES NOUVELLES INSTALLATIONS DOIVENT EMPLOYER LES INTERRUPTEURS DE CIRCUIT MOULUS DE DÉFAUT (GFCI)