EZH2O® Bottle Filling Station
with Bi-Level Filtered High-Efciency Cooler
SPECIFICATIONS
PRODUCT SPECIFICATION
Unit shall include high-efciency bi-level electric water cooler with bottle
lling station. VRCGRNTL8WSK shall deliver 8 GPH of 50°F drinking
water at 90°F ambient and 80°F inlet water. Lower units shall have
Vandal-resistant pushbutton activation with Vandal-resistant StreamSaver™
water conservation bubbler. Bottle lling unit shall include an electronic
sensor for touchless activation with auto 20-second shut-off timer. Shall
include Green Ticker™ displaying count of plastic bottles saved from
waste. Bottle ller shall provide 1.1 gpm ow rate with laminar ow to
minimize splashing. Shall include integrated silver ion anti-microbial
protection in key areas. Unit shall meet ADA guidelines. Unit shall be
lead-free design which is certied to NSF/ANSI 61and 372 and meets
Federal and State low-lead requirements. Unit shall be certied to
UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Sanitary, touchless activation with auto 20-second shut-off (Bottle Filler)
• Vandal-resistant, easy to operate front pushbutton control (Cooler)
• WaterSentry® Plus 3000-gallon capacity Filtration System, certied to
NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
• Integrated Silver Ion Anti-microbial Protection in key areas
• Quick Fill Rate: 1.1 gpm
• Laminar Flow provides minimal splash
• Real Drain System eliminates standing water
• Visual User Interface display includes:
• Innovative Green Ticker™ counts bottles saved from waste
• Cooler panel nish: Stainless Steel
COOLING SYSTEM
• High-Efciency Compressor: hermetically-sealed, reciprocating type,
single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous
copper tubing with stainless steel tank. Fully insulated with EPS foam
which meets UL requirements for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat
is factory preset. Requires no adjustment other than for altitude
requirements.
CAPACITIES CHART
Model
LVRCGRNTL8WSK 115V / 60Hz 8 GPH 3.8 260 112
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
Ship
Wt.
Model LVRCGRNTL8WSK
RATED FOR INDOOR USE ONLY
Model
LVRCGNTL8WSK
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides
structural integrity
• Stainless steel bottle ller wrapper with ABS plastic alcove.
• Cooler cabinet is Stainless Steel construction
• Vandal-resistant StreamSaver™ water-efcient bubbler is
one-piece heavy-duty chrome-plated
Replacement Filters: Available as Singles and Multi-packs.
Order part numbers:
• 51300C (single)
• 51300C_3PK (three)
• 51300C_12PK (twelve)
• 51300C_24PK (twenty-four)
• 51300C_48PK (forty-eight)
CERTIFICATIONS / STANDARDS
• ADA Compliant
• UL399 and CAN/CSA 22.2 No. 120 Certied
• ANSI/NSF 61 and 372 Certied
• ANSI/NSF 42 and 53 Certied (Filter only)
• GreenSpec® Listed
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
Warranty: 5 year limited warranty on the unit’s refrigeration system.
Electrical components and water system are warranted for 12 months
from date of installation or 18 months from factory shipment, whichever
date falls rst.
In keeping with our policy of continuing product
improvement, Elkay reserves the right to change
specication without notice. Please visit elkaypro.com
for the most current version.
2222 Camden Court
OakBrook, IL 60523
630-572-3192
elkay.com
This specication describes an Elkay product with design,
quality and functional benets to the user. When making a
comparison of other producer’s offerings, be certain these
features are not overlooked.
© 2014 Elkay
SPEC14-74 (09/2014)
EZH2O® Bottle Filling Station
with Bi-Level Filtered High-Efciency Cooler
Model LVRCGRNTL8WSK
ROUGH-IN
RATED FOR INDOOR USE ONLY
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not
been altered by materials in the cooler waterway. The grounding of electrical
equipment such as telephone, computers, etc. to water lines is a common
procedure. This grounding may be in the building but may also occur away from
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
58 9/16"
1488mm
O
MOUNTING HOLES
ACTIVATION
SENSOR
45 9/16"
1157mm
37 1/2"
952mm
7/16"
11mm
(6)
15"
381mm
5/16" (8mm) DIA.
6 1/2"
165mm
7 1/4"
185mm
20 3/8"
518mm
5 3/4"
146mm
(10 HOLES)
1 3/8"
35mm
E
F
2 9/16"
65mm
178mm
4 9/16"
116mm
5"
127mm
7"
17 7/8"
454mm
178mm
1 3/8"
35mm
C
L
10"
254mm
FINISHED FLOOR
7"
11/16"
18mm
2 7/16"
63mm
5 3/4"
146mm
18 1/16"
459mm
5 3/4"
146mm
1 3/8"
1 3/8"
35mm
35mm
C
L
3 1/2"
B
6 1/4"
159mm
89mm
4 1/2"
114mm
NOTICE
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non- metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown).
Water and electrical will connect through pre-punched hole in basin.
3 9/16"
90mm
18 5/8"
472mm
5 3/4"
146mm
13 7/8"
352mm
D
E
A
F
18 3/4"
476mm
20 1/8"
511mm
25 1/8"
638mm
39 7/16"
1002mm
ORIFICE HEIGHT
ORIFICE HEIGHT
32 15/16"
837mm
2 5/8"
67mm
31 15/16"
811mm
RIM HEIGHT
27"
686mm
ADA
REQUIREMENT
8"
203mm
105mm
HANGER BRACKET
C
4 1/8"
12 5/16"
313mm
6 3/4"
172mm
18 7/8"
479mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
© 2014 Elkay
elkay.com