G
®
reenSpec
G
c
esistant unit for use in high demand locations. Flow regulator
r
rovides constant stream from 20 to 105 psi water pressure.
p
ated for indoor and outdoor use.
R Non-pressurized cooling tank is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is subject to line pressure only when push button is pressed.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A. (Americans with Disabilities Act) when properly installed. Also meets the guidelines for children’s environments providing the floor to orifice height is 30" or less and proper clear floor space is provided for parallel approach. (Based on Architectural and Transportation Barriers Compliance Board final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined by the Safe Drinking Water Act. Elkay Water Coolers are man­ufactured with a waterway system utilizing copper compo­nents and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and con­venient removal of waterborne particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
Model Volt./ Base 70°F 80°F 90°F Rated Load Glass Wt.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Filler Lbs.
VRCGRN8
LVRCGRN8F
**Based on 80°F (27°C) inlet water temperature. Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
ENERGY-EFFICIENT COOLING SYSTEM
Motor Compressor: High-efficiency, hermetically sealed, reciprocating type, 115 Volt/60 Hz, single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Designed for optimized heat transfer within the evaporator. Fully insulated.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free operation.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. Easily accessible.
isted, energy and water efficient model. Self-
L
**GPH of 50°F
Drinking Water
Room Temperature °F
1150V/
8.0 9.7 8.8 8.0 260 2.8 66
60Hz
1150V/
8.0 9.7 8.8 8.0 260 2.8 Included 70
60Hz
Full Filter/ Ship.
GreenSpec®Listed, High Efficiency
Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model VRCGRN8
odel VRCGRN8
M
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top, polished to a uniform Elkay bright luster finish. Basin has embossed bubbler pad.
Bubbler: Water-efficient, heavy-duty, vandal-resistant bub­bler in one-piece construction. Keyed into position to prevent rotation. Meets UL requirements and all sanitary codes.
Cabinet: Cabinet design allows for flush to wall mounting. No recess space is required. Includes bottom cover plate fastened with vandal-resistant screws.
Color Selection: Stainless steel furnished as standard. Protected by Elkay’s 5 Year Limited Warranty on the refrig-
eration system of the unit. Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure. If inlet pressure is above 105 psi (724 KPa), a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi (138 KPa) or higher than 105 psi (724 KPa) is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including NSF/ANSI 61-ANNEX G, AB 1953.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 12-56B
GreenSpec®Listed, High Efficiency
®
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER
B
UILDING WATER
I
NLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
B
UILDING WATER
I
NLET
E
E
D
A
F
FINISHED FLOOR
HANGER BRACKET
B
5/16" (8mm) DIA. (5 HOLES)
C
13-7/8"
(352mm)
2-9/16"
(65mm)
8"
(203mm)
21-3/8"
(543mm)
18-3/8"
(467mm)
5-3/4"
(146mm)
2-1/2"
(62mm)
7-1/4"
(184mm)
11/16"
(18mm)
4-9/16"
(116mm)
1-1/2"
(38mm)
1-3/8"
(35mm)
1-3/8"
(35mm)
18-5/8"
(473mm)
4-1/2"
(114mm)
25"
(635mm)
5-3/4"
(146mm)
10"
(254mm)
5"
(127mm)
3-1/2"
(89mm)
27" *
(686mm)
12-5/16"
(313mm)
6-1/4"
(159mm)
32-15/16"
(837mm)
2-5/8"
(67mm)
31-7/8"
(810mm)
30-15/16"
(786mm)
C
L
ORIFICE HEIGHT
RIM HEIGHT
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH T
UBE IS SECURED
IN POSITION P
USH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
3 (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN.
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*
ADA REQUIREMENT
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. 3” (76mm) MAXIMUM OUT FROM WALL. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN. C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX. E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*
ADA REQUIREMENT
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
Wall Mount Water Cooler Vandal-Resistant, Barrier-Free Access Model VRCGRN8
ROUGH-IN DIMENSIONS
Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT!
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
he grounding of electrical equipment such as telephone, computers, etc., to
T
ater lines is a common procedure. This grounding may be in the building but
w
ay also occur away from the building. This grounding can cause electrical feed-
m
ack into a water cooler creating an electrolysis which creates a metallic taste or
b
auses an increase in the metal content of the water. This condition is avoidable
c
y installing the cooler using the proper materials as shown below.
b
his water cooler must be connected to the water supply using a dielectric
T
oupling. The cooler is furnished with a non-metallic strainer which meets this
c
equirement.
r
he drain trap which is provided by the installer should also be plastic to
T
ompletely isolate the cooler from the building plumbing system.
c
INSTALLER PLEASE NOTE:
NOTICE