LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A
INSTALLATION, CARE & USE MANUAL
LVRC8WS, LVRC8WSJO, LVRCTL8WS, LVRCTL8WSJO, Factory Prep
EZH2O Bottle Filling Station and Cooler
IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
Model LVRC8WS
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
Model LVRCTL8WS
Page 1 98980C (Rev. J - 06/16)
LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
Uses HFC-134A refrigerant
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4” WRENCH OR CRECENT WRENCH
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2” SOCKET & RATCHET WRENCH
5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN,
CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL
CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS
INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT
THE BOTTLE FILLING STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTER (GFCI).
LVRC8WS Bottle Fillers are among the easiest to install on the market today.
To insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER
APPLICABLE CODES. After installation, leave these instructions with the Fountain for
future reference.
Page 298980C (Rev. J- 06/16)
LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A
5-1/8"
131mm
18-9/16"
472mm
66mm
2-5/8"
HANGER BRACKET
48"
1219mm
8"
33-1/16"
840mm
ORIFICE
6-1/4"
159mm
1-1/2"
38mm
C
203mm
31-15/16"
811mm
RIM HEIGHT
HEIGHT
6-3/4"
171mm
12-5/16"
312mm
27"
686mm
*
LVRC8WS
7"
178mm
16-5/16"
414mm
7"
178mm
MOUNTING
5/16"
8mm
O
HOLES (3 PL)
1298mm
51-1/8"
2-9/16"
185mm
E
4-9/16"
18-1/2"
470mm
1-1/4"
32mm
1-1/4"
32mm
OBROUND HOLE (5 PL)
1/4" X 1/2" (6mm X 13mm)
116mm
E
49-1/2"
1257mm
7-1/4"
2-1/2"
11/16"
18mm
D
B
25"
635mm
65mm
F
63mm
A
13-7/8"
352mm
89mm
3-1/2"
114mm
4-1/2"
2-7/16"
63mm
10"
254mm
FINISHED FLOOR
5"
127mm
18-3/8"
467mm
21-3/8"
543mm
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL.
31"
788mm
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
Single Rough-In
Fig. 1