Elkay LRPBM8K Specifications

®
SPECIFICATIONS
GENERAL
Single station barrier-free stainless steel water cooler has recessed in-the-wall refrigeration system and stainless steel grill. Stainless tubular steel support arm incorporates unique recess to be integrated with basin. All stainless steel polished to lustrous satin finish with high shined outer edge.
Fountain has contoured basin to minimize splashing. Flexi-
Guard vandal-resistant front push button. Flow regulator provides constant stream from 20 to 105 psi water pressure.
Model LRPB8K is designed for applications with the early installation of the mounting frame, pre-ordered as MF100. The fountain and water chiller are included with LRPB8K.
THIS WATER COOLER COMPLIES WITH THE REQUIRE­MENTS OF A.D.A. (AMERICANS WITH DISABILITIES ACT) WHEN PROPERLY INSTALLED.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 198
El tem utilizing copper components and completely lead-free material. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro­vided to allow trapping and convenient removal of waterborne particulate of 140 microns and larger prior to their entry into the water cooler.
WATERSENTRY®FILTER SYSTEM
Elkay Water Coolers equipped with the WaterSentry VII Filter System. Tested to NSF/ANSI Standard 53 yields a reduction of soluble and insoluble lead content to less than 0.015mg/l. This translates to lead reduction levels of 93% to 99%. Class 1 particulate reduction as tested per NSF/ANSI 42. Remov over 97.5% of free available chlorine which provides Class 1 performance as tested to NSF/ANSI 42. Provides taste and odor improvement.
CAPACITIES CHART
**Based on 80°F inlet water temperature. Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hz or 230V, 50 Hz (International Model) single phase. Sealed-in lifetime oil supply.
Condenser:Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Tube type. Self-cleansing. Continuous copper tubing which is fully insulated with EPS foam that meets UL requirements for self-extinguising material.
safety bubbler and easy to operate, fully functional
8.
kay Water Coolers are manufactured with a waterway sys-
*GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Cooler Lbs.
LRPB(M)8K 7.5 8.6 8.1 7.5 370 4.0 No No 93
Room Temperature °F
Full Glass Ship.
Rated Load Filler Pre- Wt.
es
No Lead SwirlFlo
with WaterSentry®VII Filter System
Barrier-Free Access
Model LRPB(M)8K
Model LRPB(M)8K
Temperature Co
tory preset. Requires no adjustment other than for altitude requirements.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free performance.
CONSTRUCTION
Fountain Body: #18 gauge, type 304 nickel bearing stainless steel basin polished to a lustrous satin finish with high shined outer edge. Con mize splashing. #16 gauge, type 304 tubular support arm incorporates unique recess to accept basins. Fully functional vandal-resistant push button is easy to operate.
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Keyed in location to prevent rotation.
Front Panel Grill: Made of type 304 stainless steel, polished to a uniform Elkay satin finish. Removable louvered ventilat­ing grill encloses refrigeration unit and plumbing.
Wall Mounting Frame: MF100 frame furnished with each unit. Frame allows flush mounting to finished wall.
Protected by Elkay’s 5 Year Limited
eration system of the unit. Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
ntrol:Enclosed adjustable thermostat is fac-
toured basin offers large strike area to mini-
Safety Bubbler: Innovative design
Warranty on the refrig-
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
®
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice.
Elkay
elkaypro.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these featu overlooked.
Printed in U.S.A. ©2014 Elkay
(Rev. 4/14) 12-45C
res are not
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
NOTE: WATERFLOW
DIRECTION SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER BUILDING WATER
INLET
No Lead SwirlFlo
®
with WaterSentry®VII Filter System Barrier-Free Access Model LRPB(M)8K
®
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as tele­phone, computers, etc., to water lines is a common procedure. This grounding may be in the building or may occur away from the building. This grounding can cause electrical feedback into a water cooler, creating an electrolysis which causes a metallic taste or causes an incre the water. This condition is avoidable by using the proper materials as indicated below.
The drain fittings which are provided by the installer should also be plastic to electrically isolate the cooler from the building plumbing system.
as
e in the metal content of
LRPBM8K MOUNTING FRAME INSTRUCTIONS
1. Cut a square rectangular wall opening 18-3/4"
(476mm) W x 37-3/4" (959mm) H and 4-1/2" (114mm) above the fl are required to obtain proper rim and bubbler heights for compliance with ANSI standard A117.1. (See Figure 2)
2. Reinforce the wall opening on all sides so that it will adequately support the water fountain. This reinforcement must support up to 150 lbs static load and provide a means for securing the frame assembly in place.
NOTE: Building construction must allow for ade-
ai
r flow on both sides and top of remote
quate chiller unit. Minimum of 4" (102mm) is required. (See Figures 1 & 2)
3. Install plumbing and electrical rough-ins.
See Figure 1 for location of the supply water inlet to chiller and for the location of the waste water outlet. A junction box for a (3) wire, 10 amp branch circuit is provided on the inside of the chiller. (Standard 120 Volts, 60 Hz and single phase) See
gure 2 for the electrical inlet location.
Fi
4.Remove frame and related hardware from packaging. Release the two shelf rods by cutting cable ties. Install the frame squarely in wall opening with frame upright edges flush with the finished wall face. (See Figure 2) Place shelf inside frame and line up the (2) holes on each. Insert loose ends of rods into holes on sides of shelf panel. Using appropriate screws (not provided), fasten the shelf and frame to bottom of wall opening. (See Figure 2) Secure the frame sides and top to the wall using (10) 5/16" x2" lag bolts or screws (not provided).
NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity and size.
oor line. These dimensions
ly sized wood
WaterSentry® VII Filter System
2
(73mm)
(502mm) (356mm)
3
3 W SHUT OFF VALVE BY OTHERS
(29mm)
(79mm)
3 COLD WATER OUTLET
8
(206mm)
9
(238mm)
FIG. 1
MINIMUM DEPTH
1
1
2
(73mm)
2
(517mm)
1
(41mm)
(467mm)
(863mm)
(519mm)
REQUIREMENT
ELECTRICAL INLET
FINISHED FLOOR
5
(16mm)
(29mm)
(279mm)
5
(140mm)
BACK WALL LINE
FURNISHED
1
(25mm)
(89mm)
(203mm)
(114mm)
(730mm)
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
AB
C
TUBE TO ATTACH
IN POSITION SIMPLY PUSH IN
TUBE IS SECURED OPERATION OF QUICK CONNECT FITTINGS
TUBE TO ATTACH
A B
SIMPLY PUSH IN
TUBE IS SECURED
IN POSITION
Elkay
12-45C (Rev. 4/14)
BUILDING WATER
INLET
SERVICE STOP (NOT FURNISHED)
PUSH IN COLLET
TO RELEASE TUBE
C
RELEASE TUBE
FIG. 2
(10 REQ’D) - (NOT PROVIDED)
(NOT PROVIDED)
HOOK RODS (2)
2222 Camden Court Oak Brook, IL 60523
elkaypro.com
FRAME
(959mm)
(114mm)
CHILLER SHELF
(476mm)
(NOT PROVIDED)
(29mm)
(203mm)
(130mm)
FLOOR LINE
Printed in U.S.A. ©2014 Elkay
LOCATION ON CHILLER
TO FLOOR LINE
MIN. DEPTH
Loading...