SPECIFICATIONS
GENERAL
Single station barrier-free stainless steel water cooler has
recessed in-the-wall refrigeration system and stainless steel
grill. Stainless tubular steel support arm incorporates unique
recess to be integrated with basin. All stainless steel polished
to lustrous satin finish with high shined outer edge.
Fountain has contoured basin to minimize splashing. Flexi-
®
Guard
vandal-resistant front push button. Flow regulator provides
constant stream from 20 to 105 psi water pressure.
Model LRPB8K is designed for applications with the early
installation of the mounting frame, pre-ordered as MF100.
The fountain and water chiller are included with LRPB8K.
THIS WATER COOLER COMPLIES WITH THE REQUIREMENTS OF A.D.A. (AMERICANS WITH DISABILITIES ACT)
WHEN PROPERLY INSTALLED.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
198
El
tem utilizing copper components and completely lead-free
material. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted. A strainer with an easily cleanable screen is provided to allow trapping and convenient removal of waterborne
particulate of 140 microns and larger prior to their entry into
the water cooler.
WATERSENTRY®FILTER SYSTEM
Elkay Water Coolers equipped with the WaterSentry VII Filter
System. Tested to NSF/ANSI Standard 53 yields a reduction
of soluble and insoluble lead content to less than 0.015mg/l.
This translates to lead reduction levels of 93% to 99%. Class
1 particulate reduction as tested per NSF/ANSI 42. Remov
over 97.5% of free available chlorine which provides Class 1
performance as tested to NSF/ANSI 42. Provides taste and
odor improvement.
CAPACITIES CHART
**Based on 80°F inlet water temperature.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz or 230V, 50 Hz (International Model) single phase.
Sealed-in lifetime oil supply.
Condenser:Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Tube type. Self-cleansing. Continuous copper
tubing which is fully insulated with EPS foam that meets UL
requirements for self-extinguising material.
safety bubbler and easy to operate, fully functional
8.
kay Water Coolers are manufactured with a waterway sys-
*GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Cooler Lbs.
LRPB(M)8K 7.5 8.6 8.1 7.5 370 4.0 No No 93
Room Temperature °F
Full Glass Ship.
Rated Load Filler Pre- Wt.
es
No Lead SwirlFlo
with WaterSentry®VII Filter System
Barrier-Free Access
Model LRPB(M)8K
Model LRPB(M)8K
Temperature Co
tory preset. Requires no adjustment other than for altitude
requirements.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
CONSTRUCTION
Fountain Body: #18 gauge, type 304 nickel bearing stainless
steel basin polished to a lustrous satin finish with high shined
outer edge. Con
mize splashing. #16 gauge, type 304 tubular support arm
incorporates unique recess to accept basins. Fully functional
vandal-resistant push button is easy to operate.
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact,
then returns to original position. Strong. Abrasion-resistant.
Anti-sweat. Keyed in location to prevent rotation.
Front Panel Grill: Made of type 304 stainless steel, polished
to a uniform Elkay satin finish. Removable louvered ventilating grill encloses refrigeration unit and plumbing.
Wall Mounting Frame: MF100 frame furnished with each
unit. Frame allows flush mounting to finished wall.
Protected by Elkay’s 5 Year Limited
eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
ntrol:Enclosed adjustable thermostat is fac-
toured basin offers large strike area to mini-
®
Safety Bubbler: Innovative design
Warranty on the refrig-
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
®
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
Elkay
elkaypro.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these featu
overlooked.
Printed in U.S.A.
©2014 Elkay
(Rev. 4/14) 12-45C
res are not
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
No Lead SwirlFlo
®
with WaterSentry®VII Filter System
Barrier-Free Access
Model LRPB(M)8K
®
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common
procedure. This grounding may be in the building or
may occur away from the building. This grounding
can cause electrical feedback into a water cooler,
creating an electrolysis which causes a metallic
taste or causes an incre
the water. This condition is avoidable by using the
proper materials as indicated below.
The drain fittings which are provided by the installer
should also be plastic to electrically isolate the cooler
from the building plumbing system.
as
e in the metal content of
LRPBM8K MOUNTING FRAME INSTRUCTIONS
1. Cut a square rectangular wall opening 18-3/4"
(476mm) W x 37-3/4" (959mm) H and 4-1/2"
(114mm) above the fl
are required to obtain proper rim and bubbler
heights for compliance with ANSI standard
A117.1. (See Figure 2)
2. Reinforce the wall opening on all sides so that it
will adequately support the water fountain. This
reinforcement must support up to 150 lbs static
load and provide a means for securing the frame
assembly in place.
NOTE: Building construction must allow for ade-
ai
r flow on both sides and top of remote
quate
chiller unit. Minimum of 4" (102mm) is required.
(See Figures 1 & 2)
3. Install plumbing and electrical rough-ins.
See Figure 1 for location of the supply water inlet
to chiller and for the location of the waste water
outlet. A junction box for a (3) wire, 10 amp branch
circuit is provided on the inside of the chiller.
(Standard 120 Volts, 60 Hz and single phase) See
gure 2 for the electrical inlet location.
Fi
4.Remove frame and related hardware from
packaging. Release the two shelf rods by cutting
cable ties. Install the frame squarely in wall
opening with frame upright edges flush with the
finished wall face. (See Figure 2) Place shelf
inside frame and line up the (2) holes on each.
Insert loose ends of rods into holes on sides of
shelf panel. Using appropriate
screws (not provided), fasten the shelf and frame
to bottom of wall opening. (See Figure 2) Secure
the frame sides and top to the wall using (10)
5/16" x2" lag bolts or screws (not provided).
NOTE: Be sure that frame is squared in location.
Do not use less than the required screw quantity
and size.
oor line. These dimensions
ly sized wood
WaterSentry® VII Filter System
2
(73mm)
(502mm)
(356mm)
3
3
W
SHUT OFF VALVE BY OTHERS
(29mm)
(79mm)
3
COLD WATER OUTLET
8
(206mm)
9
(238mm)
FIG. 1
MINIMUM DEPTH
1
1
2
(73mm)
2
(517mm)
1
(41mm)
(467mm)
(863mm)
(519mm)
REQUIREMENT
ELECTRICAL INLET
FINISHED FLOOR
5
(16mm)
(29mm)
(279mm)
5
(140mm)
BACK WALL LINE
FURNISHED
1
(25mm)
(89mm)
(203mm)
(114mm)
(730mm)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
AB
C
TUBE TO ATTACH
IN POSITION
SIMPLY PUSH IN
TUBE IS SECURED
OPERATION OF QUICK CONNECT FITTINGS
TUBE TO ATTACH
A B
SIMPLY PUSH IN
TUBE IS SECURED
IN POSITION
Elkay
12-45C (Rev. 4/14)
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
PUSH IN COLLET
TO RELEASE TUBE
C
RELEASE TUBE
FIG. 2
(10 REQ’D) - (NOT PROVIDED)
(NOT PROVIDED)
HOOK RODS (2)
2222 Camden Court
Oak Brook, IL 60523
elkaypro.com
FRAME
(959mm)
(114mm)
CHILLER SHELF
(476mm)
(NOT PROVIDED)
(29mm)
(203mm)
(130mm)
FLOOR LINE
Printed in U.S.A.
©2014 Elkay
LOCATION ON CHILLER
TO FLOOR LINE
MIN. DEPTH