Elkay ERPA2-8RAC*A, ERPAVR2-8C*A, LPTEA8C*A, ERPAVR2-8RAC*A, LPTEA8RAC*A Installation, Care & Use Manual

...
Page 1
ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
Installation/Care/Use Manual
SwirlFlo® Refrigerated Fountains with FLEXI-GUARD
®
SEE FIG. 4 OR 5
42
SEE FIG. 11
38, 40, 41
35 44
37, 39, 41
36
44
ERP A2-8C, LPTEA8C
ERPA2-8RAC, LPTEA8RAC
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA­TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. T O WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR AW A Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELEC­TROLYSIS WHICH CAUSES A MET ALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MATERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
FIG. 1
FIG. 3
NOTE: WATER FLOW
DIRECTION
48
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
45
BASIN
46
47
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
1
FIG. 4
2
FIG. 2
NOTE: WHEN INSTALLING REPLACEMENT BUBBLER
3
AND PEDESTAL, TIGHTEN NUT (ITEM 5 OR 33) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT
4
OVER TIGHTEN.
5
51
49
33
FIG. 5
97876C (REV. D - 12/04)
Page 2
ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
LPTEA8C LPTEA8RAC
97876C (REV. D - 12/04)
FIG. 6
PAGE 2
LEGEND
A = 1/4" O.D. TUBE CONNECT (CHILLER WATER OUTLET)
B = 3/8" O.D. TUBE CONNECT (CHILLER WA TER INLET) SHUT OFF V AL VE BY OTHERS
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL INLET
Page 3
ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
INST ALLA TION INSTRUCTIONS
1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left side of shelf. (See Figure 6) NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. See chiller instructions for additional instructions.
2. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union not provided). Turn on the water supply and flush the line thoroughly.
3. ERPA MODELS: Make connection between remote chiller and building supply line. Inlet port is marked on the chiller (1/4" O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install the in-line strainer (provided with chiller) by pushing it in until it reachs a positive stop, approximately 3/4" (19mm) on the marked chiller inlet port. Connect building supply line to strainer. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. (See Figure 7). LPTEA MODEL:Mount filter head assembly to side of chiller (See Figure 9). Make connection between filter and building supply line (3/8" O.D. tube not provided). Inlet port is marked on the chiller (1/4" O.D. copper tube). Install a 1/4" x 1/4" union (provided) on the inlet port. Insert the 1/4" poly tubing (provided) into fitting on filter and connect to the union on the chiller. DO NOT SOLDER TUBES INSERTED INTO THE UNIONS AS DAMAGE TO THE O-RINGS MAY RESULT. (See Figure 8).
4. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it.
5. Install the fountain. Remove access cover plate on underside of fountains and save the screws. Mount the fountain to the upper panel and the wall frame with (4) 5/16" x 1 3/4" (44mm) long bolts and nuts (provided). Install spacers on bottom two bolts. Tighten securely.
6. Attach waste tube (1 1/4" OD) to 1 1/4" OD slip trap (provided by others).
7. ERPA MODELS: Make connections between remote chiller outlet tube and fountains. Outlet port is marked on the chiller (1/4" O.D. copper tube). Install a 1/4" tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the fountains into the tee. Turn on water supply and check for leaks. DO NOT SOLDER TUBES INSERTED INTO THE TEE AS
DAMAGE TO THE O-RINGS MAY RESULT. (See Figure 7). LPTEA MODEL: Make connections between remote chiller and fountains. Outlet port is marked on the chiller (1/4" O.D. copper
tube). Install a 1/4' tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the fountains into the tee. Turn on water supply and check for leaks. DO NOT SOLDER TUBES INSERTED INTO THE TEE AS DAMAGE TO THE O- RINGS MAY RESULT. (See Figure 8).
8. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
9. Make electrical connections to the chiller. See chiller instructions.
10. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, turn adjustment screw on regulator (Item 12). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream should hit basin approximately 6 1/2" from the bubbler.
11. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely.
12. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from orifice with a small round file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.
2. Stream Regulator: If orifice is free of material deposits, regulate flow according to instruction 10 stated above.
3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 2) To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4".
4. Caution: Cleaning of Bronzetone Models requires special care. Outer surfaces must be cleaned with a mild detergent or mixture of vinegar and water only, rinsed and wiped dry. Abrasive and acidic cleaners may eventually damage the Bronzetone finish.
ERP A2-8C /ERPA2-8RAC TUBE ROUTING
50 - TO BUBBLER
50
32
43
CHILLER OUTLET
50 - TO BUBBLER
FIG. 7
50
CHILLER INLET
TO BUBBLER
50
FIG. 8
PAGE 3
LPTEA8C /LPTEA8RAC TUBE ROUTING
TO BUBBLER
32
CHILLER OUTLET
50
50
34
50
97876C (REV. D - 12/04)
WATER INLET
Page 4
ERP A2-8C*A ERP A2-8RAC*A ERP A VR2-8C*A ERP A VR2-8RAC*A LPTEA8C*A LPTEA8RAC*A
PAR TS LIST
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
NS NS NS
PAR T NO.ITEM NO.
56073C 40322C 56011C 55997C 75580C 28322C 21810C 28324C 70426C 50986C 40045C 61313C 15005C 75555C 50198C 70410C 70425C 70378C 21705C 70002C 28325C
40206000
112627543890
22490C 51294C 51299C 28321C 70792C 70818C 70822C 70823C 70682C 15009C 70683C 28185C 28187C 27026C 21822C 21823C 21845C 21846C 70055C
55001026
55996C
111008343890
45336C 50074C 50377C 45330C
100322740560
56092C 98118C 70199C 70020C
74080053
DESCRIPTION
Bubbler Assy Orifice Assy Housing Assembly Pedestal Bubbler Locknut Push Bar Mounting Bracket Push Bar Assy Regulator Activator Arm Screw - #8-32 X .25 THMS Holder-Regulator Hex Nut Regulator Retaining Nut Clip Bushing - Nylon Rod - Pivot Rod - Pivot Rod - Push Clip - Push Rod Screw - #10 X .50 HHSM Pivot Rod Bracket Retainer Screw - #10-24 X .37 PHTC Filter Mounting Bracket Filter Head Assy Filter Assy Regulator Mounting Bracket Screw - #8-18 x .75" PH Elbow - 3/8" (10mm) Fitting - Superseal 1/4" (6mm) Fitting - Superseal 3/8" (10mm) Tee - 1/4 Bubbler-Nipple-(VR Model Only) Union - 1/4 X 1/4 Back Panel RH ADA Back Panel LH ADA Lower Panel Ftn Body & Shell-Short Ftn Body & Shell-Long Cover Plate-Short Cover Plate-Long Speed Nut Basin-Swirlflow Strainer Screw - #10-24 X .62 HHMS Strainer & Ferrule Assembly Gasket - Tailpipe Gasket - Tailpipe Waste Arm Gasket-(VR Model Only) Poly Tubing (Cut To Length) Bubbler Assembly (VR Model Only) Bolt - 5/16-18 x 1.75 Lg. Nut - Hex 5/16-18 Spacer
14
FIG. 9
FIG. 10
15
28
24
25
30
31
26
RH ADA LH ADA
7
15
18
22
20
11
27
12
13
29
15
6
8
22
97876C (REV. D - 12/04)
19
16
9
FIG . 1 1
50
50
10 20
21
www.DrinkingFountainDoctor.com 800-518-5388
PAGE 4
15
15
23
15
17
Loading...