Soft Sides® Water Cooler
With WaterSentry® VII Filter System
Barrier-Free Access
Models LNFE(M)8(VR)(F)K
GENERAL
Single station barrier-free stainless steel water cooler has recessed
in-the-wall refrigeration system and stainless steel grill. All stainless steel
polished to a satin nish.
Fountain has contoured basin to minimize splashing. Flexi-Guard® safety
bubbler and easy to operate, fully functional, vandal-resistant front push
button. Flow regulator provides constant stream from 20 to 105 psi water
pressure. Vandal-resistant bottom cover plate included.
Energy efcient refrigeration system utilizes a combination tank
continuous-tube type evaporator, refrigerant drier, and capillary tube.
THIS WATER COOLER COMPLIES WITH THE REQUIREMENTS OF
A.D.A. (AMERICANS WITH DISABILITIES ACT) WHEN PROPERLY
INSTALLED.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986
AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay LNFEM8K Water Coolers are manufactured with a waterway system
utilizing copper components and completely lead-free material. These
waterways have no lead because all lead materials, such as leaded brass,
have been removed. All joints are brazed using silver solder only. No lead
solder is permitted.
WATERSENTRY FILTER SYSTEM
®
Elkay LNFEM8K Water Coolers are equipped with the WaterSentry® VII
Filter System. Tested to ANSI/NSF Standard 53 yields a reduction of soluble
and in-soluble lead content to less than 0.015mg/L. This translates to lead
reduction levels of 93% to 99%. Class 1 Particulate reduction as tested
per ANSI/NSF 42. Removes over 97.5% of free available chlorine which
provides Class 1 performance as tested to ANSI/NSF 42. Provides taste
and odor improvement.
CAPACITIES CHART
Model
Number
LNFE(M)8(VR)(F)K 8.6 8.1 7.5 325 4.5 Yes No 104
*Based on 80°F inlet water temperature.
t
Glass Filler available at extra cost. Requires factory preparation to receive glass ller.
Order Model LNFEM8FK or LNFE8FK. Glass ller LK1110 or LK1114 sold separately.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specic applications will determine the actual watts
consumed per hour. Watts consumed will be number of people served per hour
(usage), ambient temperatures, and inlet water temperature.
GPH of 50° F
Drinking Water
Room Temperature °F
70°F 80°F 90°F
Rated
Watts
F.L.
Amps
Glasst
Filler
Option
Pre-
Cooler
Ship.
Wt.
Lbs.
COOLING SYSTEM
• Motor Compressor: Hermetically sealed, reciprocating type,115v/60 Hz
single phase. Sealed-in lifetime oil supply.
• Condenser: Fan cooled, Fan motor is permanently lubricated.
• Cooling Unit: Combination tube-tank type. Continuous copper tubing
with stainless steel tank. Fully insulated with EPS foam which meets
Underwriters Laboratories Inc. requirements for self-extinguishing
material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Contol: Enclosed adjustable thermostat is factory preset.
Requires no adjustment other than for altitude requirements.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice.
Please visit elkay.com for the most current version.
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Model LNFEM8K, LNFEM8FK –
Mounting frame MF100 is included
Model LNFE8K, LNFE8FK –
Used when mounting frame MF100 is
pre-ordered for early installation
Model LNFEM8K
CONSTRUCTION
Fountain Body: #18 gauge, type 304 nickel bearing stainless steel polished
to a lustrous satin nish with high shined outer edge. Contoured basin offers
large strike area to minimize splashing. Fully functional from push button is
easy to operate.
Exclusive Flexi-Guard® Safety Bubbler: Innovative design utilizes an
infused anti-microbial pliable polyester elastomer to prevent accidental
mouth injuries. Flexes on impact, then returns to original position. Strong.
Abrasion-resistant. Anti-sweat.
BUBBLER OPTION
Vandal-Resistant Bubbler: (option) One-piece, heavy-duty, highly
polished 304 stainless steel, solid construction. Model LNFEM8VRK.
Front Panel Grill: Made of type 304 stainless steel, polished to a uniform
Elkay satin nish. Removable louvered ventilating grill encloses refrigeration
unit and plumbing.
Wall Mounting Frame: MF100 is included with model LNFEM8K, and
LNFEM8FK. For models LNFE8K, LNFE8FK, MF100 must be pre-ordered
for installation. Frame allows ush mounting nished wall.
Drain LK464 drain and trap assembly included.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system
of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on
20-105 psi supply line pressure. If inlet pressure is above 105 psi, a
pressure regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line pressures
lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by
Underwriters Laboratories Inc. and comply with both
Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This fountain is certied by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
This specication describes an Elkay product with design, quality and functional
benets to the user. When making a comparison of other producer’s offerings, be
certain these features are not overlooked.
© 2014 Elkay
SPEC08-16 (12/2014)
Soft Sides® Water Cooler
With WaterSentry® VII Filter System
Barrier-Free Access
Models LNFE(M)8(VR)(F)K
IMPORTANT!
INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone,
computers, etc., to water lines is a common procedure. This
grounding may be in the building or may occur away from the
building. This grounding can cause electrical feedback into a
water cooler, creating an electrolysis which causes a metallic
taste or an increase in the metal content of the water. This
condition is avoidable by using the proper materials as indicated
below.
To minimize electrically induced corrosion, all water coolers
should be connected to the water supply using an electrically
isolating coupling. This cooler is furnished with non-metallic
lter which meets this requirement.
The drain ttings which are provided by the installer should
also be plastic to electrically isolate the cooler from the building
plumbing system.
LNFEM8K MOUNTING FRAME INSTRUCTIONS
1. Cut a square rectangular wall opening 18-3/4” (476mm) W
x 37-3/4” (959mm) H and 4-1/2” (114mm) above the oor
line. These dimensions are required to obtain proper rim and
bubbler heights for compliance with ANSI standard A117.1.
(See Figure 2).
2. Reinforce the wall opening on all sides so that it will
adequately support the water fountain. This reinforcement
must support up to 150 lbs. static load and provide a means
for securing the frame assembly in place.
NOTE: Building construction must allow for adequate air ow
on both sides and top of remote chiller unit. Minimum of 4”
(102mm) is required. (See Figures 1 and 2).
3. Install plumbing and electrical rough-ins. See Figure 1 for
location of the supply water inlet to chiller and for the location
of the waste water outlet. A junction box for a (3) wire, 10
amp branch circuit is provided on the inside of the chiller.
(Standard 120 Volts, 60 Hz and single phase) See Figure 2
for the electrical inlet location
4. Remove frame and related hardware from packaging.
Release the two shelf rods by cutting cable ties. Install the
frame squarely in wall opening with frame upright edges
ush with the nished wall face. (See Figure 2). Place shelf
inside frame and line up the (2) holes on each.
Insert loose ends of rods into holes on sides of shelf panel.
Using appropriately sized wood screws (not provided),
fasten the shelf and frame to bottom of wall opening. (See
Figure 2). Secure the frame sides and top to the wall using
(10) 5/16” x 2” lag bolts or screws (not provided).
NOTE: Be sure thatframe is squared in location. Do not use
less than the required screw quantity.
ROUGH-IN DIMENSIONS
FIG. 1
Flexi-Guard® Bubbler (standard)
Vandal-Resistant Bubbler (optional)
19-3/4"
502mm
3-13/16"
97mm
Mounting frame MF100 not included
with model LNFE8K, LNFE8FK
12-1/8"
308mm
FIG. 2
FRAME
3-13/16"
97mm
20-3/8"
518mm
20-7/16"
519mm
33-1/2"
851mm
851mm
REQUIREMENT
27"
686mm
ADA
WALL LINE
18"
457mm
457mm
FINISHED FLOOR
3-1/8"
79mm
1-1/8"
29mm
29mm
B
5-1/2"
140mm
140mm
80mm
12"
305mm
305mm
MINIMUM DEPTH
1-1/8"
29mm
29mm
11"
279mm
279mm
WOOD OR STEEL FRAME SHOWN
(NOT PROVIDED)
A
9-3/8"
8-1/8"
238mm
206mm
238mm
206mm
BACK WALL LINE
C
1"
25mm
25mm
31-1/4"
794mm
794mm
3-1/2"
89mm
89mm
4-1/2"
114mm
114mm
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
Page 2
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
5/16" SCREWS OR BOLTS
(10 REQ'D-NOT PROVIDED)
HOOK RODS (2)
P/N 101567443730
SCREWS OR BOLTS
(NOT PROVIDED)
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
37-3/4"
959mm
4-1/2
114mm
CHILLER SHELF
P/N 27638C
18-3/4"
476mm
FLOOR LINE
1-1/8"
29mm
5-1/8"
130mm
ELECTRICAL INLET
LOCATION ON CHILLER
TO FLOOR LINE
8"
203mm
BACK OF WALL TO
BE 12" (305mm)
MIN DEPTH
Printed in U.S.A.
© 2014 Elkay