SPECIFICATIONS
GENERAL
Single station barrier-free stainless steel water cooler has
recessed in-the-wall refrigeration system and stainless steel
grill. All stainless steel polished to a satin finish.
Fountain has contoured basin to minimize splashing. FlexiGuard®safety bubbler and easy to operate, fully functional,
vandal-resistant front push button. Patented* valve and in-line
flow regulators provides constant stream from 20 to 105 psi.
Vandal-resistant bottom cover plate included.
Energy efficient refrigeration system utilizes a combination
tank continuous-tube type evaporator, refrigerant drier, and
capillary tube.
THIS WATER COOLER COMPLIES WITH THE REQUIREMENTS OF A.D.A. (AMERICANS WITH DISABILITIES ACT)
WHEN PROPERLY INSTALLED.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay LNFE8C Water Coolers are manufactured with a waterway system utilizing copper components and completely
lead-free material. These waterways have no lead because all
lead materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted.
WATERSENTRY®FILTER SYSTEM
Elkay LNFE8C Water Coolers are equipped with the
WaterSentry VII Filter System, which is tested and certified by
NSF International. The WaterSentry VII Filter System reduces
cysts such as cryptosporidium and giardia by 99.99%. Tested
to ANSI/NSF Standard 53 yields a reduction of soluble and insoluble lead content to less than 0.015mg/l. This translates to
lead reduction levels of 93% to 99%. Class 1 particulate
reduction as tested per ANSI/NSF 42. Removes over 97.5% of
free available chlorine which provides Class 1 performance as
tested to ANSI/NSF 42. Provides taste and odor improvement.
This water cooler is classified by Underwriters
Laboratories Inc. in accordance with ANSI/NSF61,
Section 9-1997b.
CAPACITIES CHART
*GPH of 50°F Drinking Water
Model
Number 70°F 80°F 90°F Watts Amps Option Cooler Lbs.
LNFE8C 8.6 8.1 7.5 325 4.5 Yes No 104
*Based on 80°F inlet water temperature.
†Glass filler available at extra cost. Requires factory preparation to receive glass
filler. Order Model LNFE8FC. Glass filler LK1110 or LK1114 sold separately.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz single phase. Sealed-in lifetime oil supply.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Self cleansing. Tube
portion is continuous coil of copper tubing. Tank is stainless
steel. Fully insulated with EPS foam which meets Underwriters
Laboratories Inc. requirements for self extinguishing material.
Full Glass† Ship.
Rated Load Filler Pre- Wt.
Soft Sides®Water Cooler
With WaterSentry®VII Filter System
Barrier-Free Access
Model LNFE8C
Model LNFE8C
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
CONSTRUCTION
Fountain Body: #18 gauge, type 304 nickel bearing stainless
steel polished to a lustrous satin finish with high shined outer
edge. Contoured basin offers large strike area to minimize
splashing. Fully functional front push button is easy to operate.
Exclusive Flexi-Guard®Safety Bubbler**: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Antisweat. Keyed in location to prevent rotation.
Front Panel Grill: Made of type 304 stainless steel, polished
to a uniform Elkay satin finish. Removable louvered ventilating grill encloses refrigeration unit and plumbing.
Wall Mounting Frame: MF100 frame furnished with each
unit. Frame allows flush mounting to finished wall.
Drain: LK464 drain and trap assembly included.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are warranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
Rated in accordance with A.R.I. Standard 1010
and meets all known federal and state plumbing
codes.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
Elkay
www.elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
** Patent #4,481,971
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2003 Elkay
(Rev. 9/03) 8-16C
3/8" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
8-1/8"
(206mm)
9-3/8"
(238mm)
18-3/4"
(476mm)
3-1/8"
(80mm)
1-1/8"
(29mm)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
FILTER
LOCATION
WALL LINE
12"
(305mm)
MINIMUM DEPTH
BACK WALL LINE
1-1/4" (32mm)
TRAP FURNISHED
31-1/4"
(794mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
11"
(279mm)
1-1/8"
(29mm)
ELECTRICAL INLET
18"
(457mm)
*
A.D.A. REQUIREMENT
33-1/2"
(851mm)
FINISHED FLOOR
20-7/16"
(519mm)
20-3/8"
(517mm)
3-13/16"
(97mm)
19-3/4"
(502mm)
12-1/8"
(308mm)
3-13/16"
(97mm)
1-5/8"
(42mm)
27"
*
(686mm)
5-1/2"
(140mm)
7-1/16"
(179mm)
1"
(25mm)
FLOOR LINE
CHILLER SHELF
P/N 27638C
18-3/4"
(476mm)
5-1/8"
(130mm)
BACK OF WALL TO
BE 12" (305mm)
MIN. DEPTH
8"
(203mm)
TO FLOOR LINE
ELECTRICAL INLET
LOCATION ON CHILLER
1-1/8"
(29mm)
WOOD OR STEEL FRAME SHOWN
(NOT PROVIDED)
37-3/4"
(959mm)
4-1/2"
(114mm)
FRAME
P/N 27049C
5/16" SCREWS OR BOLTS
(10 REQ’D) - (NOT PROVIDED)
SCREWS OR BOLTS
(NOT PROVIDED)
HOOK RODS (2)
P/N 10-15674-43-730
WaterSentry® VII Filter System
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B
C
Soft Sides®Water Cooler
With WaterSentry®VII Filter System
Barrier-Free Access
Model LNFE8C
IMPORTANT!
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common
procedure. This grounding may be in the building or
may occur away from the building. This grounding
can cause electrical feedback into a water cooler,
creating an electrolysis which causes a metallic
taste or an increase in the metal content of the water
This condition is avoidable by using the proper
materials as indicated below.
To minimize electrically induced corrosion, all water
coolers should be connected to the water supply
using an electrically isolating coupling. This cooler is
furnished with non-metallic filter which meets this
requirement.
The drain fittings which are provided by the installer
should also be plastic to electrically isolate the cooler
from the building plumbing system.
LNFE8C MOUNTING FRAME INSTRUCTIONS
1. Cut a square rectangular wall opening 18-3/4"
2. Reinforce the wall opening on all sides so that it
3. Install plumbing and electrical rough-ins.
4.Remove frame and related hardware from
INSTALLER PLEASE NOTE:
(476mm) W x 37-3/4" (959mm) H and 4-1/2"
(114mm) above the floor line. These dimensions
are required to obtain proper rim and bubbler
heights for compliance with ANSI standard
A117.1. (See Figure 2)
will adequately support the water fountain. This
reinforcement must support up to 150 lbs static
load and provide a means for securing the frame
assembly in place.
NOTE: Building construction must allow for adequate air flow on both sides and top of remote
chiller unit. Minimum of 4" (102mm) is required.
(See Figures 1 & 2)
See Figure 1 for location of the supply water inlet
to chiller and for the location of the waste water
outlet. A junction box for a (3) wire, 10 amp branch
circuit is provided on the inside of the chiller.
(Standard 120 Volts, 60 Hz and single phase) See
Figure 2 for the electrical inlet location.
packaging. Release the two shelf rods by cutting
cable ties. Install the frame squarely in wall
opening with frame upright edges flush with the
finished wall face. (See Figure 2) Place shelf
inside frame and line up the (2) holes on each.
Insert loose ends of rods into holes on sides of
shelf panel. Using appropriately sized wood
screws (not provided), fasten the shelf and frame
to bottom of wall opening. (See Figure 2) Secure
the frame sides and top to the wall using (10)
5/16"x2" lag bolts or screws (not provided).
NOTE: Be sure that frame is squared in location.
Do not use less than the required screw quantity
and size.
.
FIG. 1
FIG. 2
ROUGH-IN DIMENSIONS
Elkay
8-16C (Rev. 9/03)
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2003 Elkay