Elkay LMABFTLDDC User Manual

Two Station Wall Mount Water Cooler with Water
®
Sentry®VII Filter System – Barrier-Free Access
SPECIFICATIONS
ENERAL
G
Self-contained, double wall hung electric refrigerated, water cooler. Capacity 8.0 GPH of 50°F drinking water, based upon 80°F inlet water and 90°F ambient.
All models have a hooded stream projector with self closing push bars on front and both right and left sides. Flow regula­tor provides constant stream from 20 to 105 psi water pres­sure. Bubbler orifice fully protected to meet all sanitary codes.
Pressurized stainless steel evaporator/storage tank for long life. Waterways are certified NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. Stainless steel water tank is located after bubbler valve, so that the tank is subject to line pressure only when push bar is pressed.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A. (Americans with Disabilities Act) when properly installed. Also meets the guidelines for children’s environments providing the floor to orifice height is 30" or less and proper clear floor space is provided for parallel approach. (Based on Architectural and Transportation Barriers Compliance Board final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined by the Safe Drinking Water Act. Elkay Water Coolers are man­ufactured with a waterway system utilizing copper compo­nents and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and con­venient removal of waterborne particulate of 140 microns and larger prior to their entry into the water cooler.
WATERSENTRY®VII FILTER SYSTEM
Elkay Water Coolers are equipped with the WaterSentry VII Filter System. Tested to NSF/ANSI Standard 53 yields a reduction of soluble and insoluble lead content to less than 0.015mg/l. This translates to lead reduction levels of 93% to 99%. Class 1 partic­ulate reduction as tested per NSF/ANSI 42. Removes over
97.5% of free available chlorine which provides Class 1 perform­ance as tested to NSF/ANSI 42. Provides taste and odor improvement.
CAPACITIES CHART
**GPH of 50°F
Drinking Water
Room Temperature °F
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option (Kg.)
LMABFTL8C
LMABFTLDDC ––––– – – No 74
**Based on 80°F (27°C) inlet water temperature. Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
120V/
8.0 9.7 8.8 8.0 370 4.0 No 96
60Hz
Full Glass Wt.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 120 Volt/60 Hz, single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
Ship.
2222 Camden Court Oak Brook, IL 60523
(Adult or Child) – NSF/ANSI 61 Compliant
Models LMABFTL8C and LMABFTLDDC
Model LMABFTL8C
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. require­ments for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free operation.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top, polished to a uniform Elkay bright luster finish. Basin has embossed bubbler pad.
Exclusive Flexi-Guard
utilizes a pliable polyester elastomer to prevent accidental mouth injuries. Flex on impact, then returns to original posi­tion. Strong. Abrasion-resistant. Anti-sweat. Bubbler meets UL requirements and all sanitary codes and is keyed in loca­tion to prevent rotation.
Cabinet: Cabinet design allows for flush to wall mounting. No recess space is required. Includes bottom cover plate fastened with standard screws.
Color Selection: Light Gray Granite furnished as standard. Stainless steel available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure. If inlet pressure is above 105 psi (724 KPa), a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi (138 KPa) or higher than 105 psi (724 KPa) is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including NSF/ANSI 61-ANNEX G, AB 1953.
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
®
Safety Bubbler: Innovative design
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 12-55C
Two Station Wall Mount Water Cooler with Water
®
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH TUBE IS SECURED
IN POSITION PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
NOTE: WATERFLOW
DIRECTION SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER BUILDING WATER
I
NLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP (NOT FURNISHED)
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
I
NLET
LEGEND:
A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL. ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
E
F
B
D
E
A
F
H
ANGER BRACKET
C
FINISHED FLOOR
5/16" (8mm) DIA.
(10 HOLES)
1-3/8"
(35mm) 1-3/8"
(35mm)
5-3/4"
(146mm) 5-3/4"
(146mm)
18-1/16"
(459mm)
1-3/8"
(35mm) 1
-3/8"
(35mm)
5-3/4"
(146mm) 5-3/4"
(146mm)
6-1/2"
(165mm)
13-7/8"
(352mm)
20-3/8"
(517mm)
27"
(686mm)
2-7/16"
(63mm)
5"
(127mm) 10"
(254mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
5"
(127mm)
18-3/4"
(476mm)
20-1/8"
(511mm)
25-1/8"
(638mm)
7-1/4"
(185mm))
37-1/2"
(951mm)
4-9/16"
(116mm)
11/16"
(18mm)
12-5/16"
(313mm)
6-3/4"
(171mm)
4-3/4"
(121mm)
8"
(203mm)
18-5/8"
(473mm)
31-7/8"
(810mm)
RIM
HEIGHT
2-9/16"
(65mm)
33"
(838mm)
ORIFICE
HEIGHT
39-1/2"
(1003mm)
ORIFICE
HEIGHT
2-5/8"
(67mm)
FILTER
LEGEND: A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL.
ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
E
F
B
D
E
A
F
H
ANGER BRACKET
C
FINISHED FLOOR
5/16" (8mm) DIA.
(10 HOLES)
1-3/8"
(35mm)
1-3/8" (35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
18-1/16"
(459mm)
1-3/8" (35mm)
1
-3/8"
(35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
6-1/2"
(165mm)
13-7/8"
(352mm)
20-3/8"
(517mm)
27"
(686mm)
2-7/16"
(63mm)
5"
(127mm)
10"
(254mm)
3-1/2" (89mm)
4-1/2"
(114mm)
5"
(127mm)
18-3/4"
(476mm)
20-1/8"
(511mm)
25-1/8"
(638mm)
7-1/4"
(185mm))
37-1/2"
(951mm)
4-9/16" (116mm)
11/16" (18mm)
12-5/16"
(313mm)
6-3/4"
(171mm)
4-3/4"
(121mm)
8"
(203mm)
18-5/8" (473mm)
31-7/8" (810mm)
RIM
HEIGHT
2-9/16" (65mm)
33"
(838mm)
ORIFICE
HEIGHT
39-1/2"
(1003mm)
ORIFICE
HEIGHT
2-5/8"
(67mm)
FILTER
Sentry®VII Filter System – Barrier-Free Access (Adult or Child) – NSF/ANSI 61 Compliant Models LMABFTL8C and LMABFTLDDC
THIS WATER COOLER HAS BEEN DESIGNED AND BUILT TO PROVIDE WATER TO THE USER
HICH HAS NOT BEEN ALTERED BY MATERIALS IN THE COOLER WATERWAYS. THE
W
ROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
G WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING
UT MAY ALSO OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
B
LECTRICAL FEEDBACK INTO A WATER COOLER CREATING AN ELECTROLYSIS WHICH
E CREATES A METALLIC TASTE OR CAUSES AN INCREASE IN THE METAL CONTENT OF THE
ATER. THIS CONDITION IS AVOIDABLE BY INSTALLING THE COOLER USING THE PROPER
W
ATERIALS AS SHOWN BELOW.
M
THIS WATER COOLER MUST BE CONNECTED TO THE WATER SUPPLY USING A DIELECTRIC
OUPLING. THE COOLER IS FURNISHED WITH A NON-METALLIC STRAINER WHICH MEETS
C THIS REQUIREMENT. THE DRAIN TRAP WHICH IS PROVIDED BY THE INSTALLER SHOULD ALSO BE PLASTIC TO COMPLETELY ISOLATE THE COOLER FROM THE BUILDING PLUMBING SYSTEM.
MINIMUM 40 PSI SUPPLY LINE PRESSURE REQUIRED IN SPECIAL CIRCUMSTANCES WHEN BOTH
IDES OF BILEVEL ARE IN USE SIMULTANEOUSLY TO ENSURE ADEQUATE STREAM HEIGHT. DOES
S
OT APPLY TO NON-REFRIGERATED UNITS.
N
ROUGH-IN DIMENSIONS
NSTALLER PLEASE NOTE:
I
IMPORTANT
NOTICE
Elkay
12-55C (Rev. 4/11)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2011 Elkay