Wall Mount Water Cooler with Water Sentry®VII
SPECIFICATIONS
ENERAL
G
Self-contained, wall hung electric refrigerated, water cooler.
Capacity 8.0 GPH of 50°F drinking water, based upon 80°F
inlet water and 90°F ambient.
All models have a hooded stream projector with self closing
push bars on front and both right and left sides. Flow regulator provide constant stream from 20 to 105 psi water pressure. Bubbler orifice fully protected to meet all sanitary codes.
Non-pressurized cooling tank is standard. Non-pressurized
water tank is located after bubbler valve, so that the tank is
subject to line pressure only when push bar is pressed.
ADA COMPLIANT
hese Water Coolers comply with the requirements of A.D.A.
T
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and convenient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
WATERSENTRY®VII FILTER SYSTEM
Elkay Water Coolers are equipped with the WaterSentry VII Filter
System. Tested to NSF/ANSI Standard 53 yields a reduction of
soluble and insoluble lead content to less than 0.015mg/l. This
translates to lead reduction levels of 93% to 99%. Class 1 particulate reduction as tested per NSF/ANSI 42. Removes over
97.5% of free available chlorine which provides Class 1 performance as tested to NSF/ANSI 42. Provides taste and odor
improvement.
CAPACITIES CHART
**GPH of 50°F
Drinking Water
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option (Kg.)
LMABF8
LMABFD ––––– – – No 39
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
120V/
60Hz
Room Temperature °F
8.0 9.7 8.8 8.0 370 4.0 No 67
Full Glass Wt.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Ship.
Filter System – Barrier-Free Access
(Adult or Child) – NSF/ANSI 61 Compliant
Models LMABF8 and LMABFD
odel LMABF8
M
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
®
Exclusive Flexi-Guard
utilizes a pliable polyester elastomer to prevent accidental
mouth injuries. Flex on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Bubbler meets
UL requirements and all sanitary codes and is keyed in location to prevent rotation.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with standard screws.
Color Selection: Light Gray Granite furnished as standard.
Stainless steel available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 12-52B
Wall Mount Water Cooler with Water Sentry®VII
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
B
UILDING WATER
I
NLET
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
B
UILDING WATER
I
NLET
LEGEND:
A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL.
ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
HANGER BRACKET
C
B
E
E
D
A
5/16" (8mm) DIA. (5 HOLES)
FINISHED FLOOR
F
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
F
ILTER
12-5/16"
(313mm)
27"
(686mm)
2-9/16"
(65mm)
18-5/8"
(472mm)
1-3/8"
(
35mm)
1
-3/8"
(35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
4-9/16"
(116mm)
2-9/16"
(65mm)
7-1/4"
(185mm)
11/16"
(18mm)
2-7/16"
(63mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
5"
(127mm)
10"
(252mm)
2-1/2"
(64mm)
13-7/8"
(351mm)
18-3/8"
(467mm)
21-3/8"
(543mm)
25"
(635mm)
31"
(787mm)
8"
202mm
6-1/4"
(159mm)
31-7/8"
(810mm)
RIM
HEIGHT
33"
(838mm)
ORIFICE
HEIGHT
LEGEND:
A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL.
ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
HANGER BRACKET
C
B
E
E
D
A
5/16" (8mm) DIA. (5 HOLES)
FINISHED FLOOR
F
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
F
ILTE R
12-5/16"
(313mm)
27"
(686mm)
2-9/16"
(65mm)
18-5/8"
(472mm)
1-3/8"
(
35mm)
1
-3/8"
(35mm)
5-3/4"
(146mm)
5-3/4"
(146mm)
4-9/16"
(116mm)
2-9/16"
(65mm)
7-1/4"
(185mm)
11/16"
(18mm)
2-7/16"
(63mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
5"
(127mm)
10"
(252mm)
2-1/2"
(64mm)
13-7/8"
(351mm)
18-3/8"
(467mm)
21-3/8"
(543mm)
25"
(635mm)
31"
(787mm)
8"
202mm
6-1/4"
(159mm)
31-7/8"
(810mm)
RIM
HEIGHT
33"
(838mm)
ORIFICE
HEIGHT
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
T
UBE TO ATTACH
T
UBE IS SECURED
I
N POSITION
P
USH IN COLLET
T
O RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
T
UBE TO ATTACH
T
UBE IS SECURED
I
N POSITION
P
USH IN COLLET
T
O RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
Filter System – Barrier-Free Access
(Adult or Child) – NSF/ANSI 61 Compliant
Models LMABF8 and LMABFD
Open space rough-in design permits new installation or replacement of existing
fountains and coolers with this Elkay cooler when rough-in is within the outline
shown.
This water cooler has been designed and built to provide water to the user which
has not been altered by materials in the cooler waterways.
he grounding of electrical equipment such as telephone, computers, etc., to
T
ater lines is a common procedure. This grounding may be in the building but
w
ay also occur away from the building. This grounding can cause electrical feed-
m
ack into a water cooler creating an electrolysis which creates a metallic taste or
b
auses an increase in the metal content of the water. This condition is avoidable
c
y installing the cooler using the proper materials as shown below.
b
his water cooler must be connected to the water supply using a dielectric
T
oupling. The cooler is furnished with a non-metallic strainer which meets this
c
equirement.
r
he drain trap which is provided by the installer should also be plastic to
T
ompletely isolate the cooler from the building plumbing system.
c
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
NOTICE
Elkay
12-52B (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay