LL671-14*1C,2C
29
With FLEXI-GUARD
®
Installation/Care/Use Manual
USES HFC-134A REFRIGERANT
SEE FIG. 3
SEE FIG. 4
7
30
22, 23,
24, & 25
34 & 35
27 & 28
17, 18,
19, & 20
15 & 16
21
13
26
14
FIG. 1
PAGE 1
31 & 33
97058C (Rev. B - 4/98)

LL671-14*1C,2C
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE
MUR.
CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO
CORDON DALIMENTATION 4' (1219mm)
UBICACIÓN ALT. DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT ALTERNATIF DE LA PRISE DE COURANT
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = POWER CORD 4 FEET (1219mm) LONG
G = ALT. ELECTRICAL OUTLET LOCATION
FIG. 2
97058C (Rev. B - 4/98)
PAGE 2
FROM WALL SHUT OFF BY OTHERS
(38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
C = 1-1/4 TRAP NOT FURNISHED
EMPLACEMENT DE LA PRISE DE COURANT
D = ELECTRICAL OUTLET LOCATION

LL671-14*1C,2C
10
8
9
11
BASIN
12
NOTE:
WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN
NUT (ITEM 12) ONLY TO HOLD PARTS
SNUG IN POSITION.
DO NOT OVER TIGHTEN.
FIG. 3
Stream height is factory set at 35 PSI. If supply pressure varies
greatly from this, remove Items 1 & 2 and adjust screw on
Item 4. Clockwise adjustment will raise stream and counter-clockwise
adjustment will lower stream. For best adjustment, stream should hit
basin approximately 6-1/2" (165mm) from bubbler.
1
BASIN
2
3
4
5
6
FIG. 4
PAGE 3
97058C (Rev. B - 4/98)

PARTS LIST 115V
LL671-14*1C,2C
ITEM NO. PART NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22*
23
24
25
26
27
28
29
30
31
32
33
34
35
40089C
40048C
15005C
61313C
40169C
50986C
20776C
51349C
40322C
50934C
50168C
70012C
31513C
31502C
61013C
21516C
31490C
30664C
20239C
70018C
66202C
35762C
31027C
35766C
194243901550
55996C
45678C
55909C
66229C
66421C
27247C
50368C
27248C
70767C
70772C
DESCRIPTION
Cover
Button
Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin
Bubbler Assy
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Cold Control
Power Cord
Condenser
Fan Shroud
Fan Motor
Fan Blade
Fan Bracket
Fan Blade Nut
Drier
Compressor Serv. Pak
Overload/Relay Assy
Relay Cover
Electrical Shield
Strainer
Precooler
Tailpipe Helix
Heat Exchanger
Evaporator
Base
Receptor-Drain
Angle
Evaporator Retaining Clip
Evaporator Drain Plug
220/240v 50/60 Hz
PART. NO. DESCRIPTIONITEM NO.
14
17
22*
23
24
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers
or orders for repair parts MUST include Model No. and Serial No. of cooler,
name and part number of replacement part.
COLOR
TABLE
Gray Beige
Almond
Stainless Steel
Sandalwood
Granite
31440C
31430C
35764C
31028C
35768C
LEFT
PANEL
21072C
21472C
21080C
21470C
27159C
Power Cord
Fan Motor
Compressor Serv. Pak
Overload/Relay Assy
Relay Cover
RIGHT
PANEL
21073C
21473C
21081C
21471C
27162C
FRONT
PANEL
20675C
20676C
20672C
21454C
27150C
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484
97058C (Rev. B - 4/98)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620