Elkay LKWS7PDS Installation Manual

ELKAY WaterSentry® VII
Lead, Cyst, Aesthetic Chlorine T aste, Odor & Particulate Class I Reduction Filter
Replacement Filter P/N 51299C
FOR COMMERCIAL USE ONLY
PERFORMANCE DA T A SHEET
NOTICE: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. CAUTION: Use on cold water line only . Do not allow inst alled filter to freeze.
RECOMMENDED USE CONDITIONS
Capacity
1500 Gallons
1 Year Maximum
Maximum Pressure 105 PSI (7.4 Kg/cm2)
Flow Rate Temperature
0.75 GPM
40-120° F (5-50° C)
Minimum Pressure 20 PSI (1.4 Kg/cm2)
NOTE: Performance will vary depending on local water conditions. While testing was
performed under standard laboratory conditions actual performance may vary .
Instructions For Installing Replacement Filters
1. Turn off water supply; dispense water to relieve pressure
2. Turn used filter counterclockwise 1/4 turn to remove from filter head.
3. Remove cap from new filter and use to seal used filter.
4. Insert new filter into existing filter head and turn fully clockwise.
5. Turn on water supply and run a minimum of two gallons of water through the filter to purge air and fine carbon particles from filter. Also run water through glass filler (if provided)
Your Authorized Representative
Buyer
Seller
LIMITED WARRANTY
The ELKAY WaterSentry® VII is warranted to be free from defects in material and workmanship for a period of one year from the date of installation. Warranty is limited to repair or replacement of defective component.
PAGE 1 97299C (Rev. L - 01/08)
The ELKA Y WaterSentry® VII filter conforms to NSF/ANSI 42 and 53 for the reduction of aesthetic chlorine, taste and odor , particulate class 1, lead and cysts as verified and substantiated by test data.
Performance Test Conditions
NSF/ANSI 42
Aesthetic Chlorine
Particulate - Class I
Taste and Odor Reduction
NSF/ANSI 53
Lead Reduction
Cyst Reduction
Capacity Flow Rate Pressure Temperature
1500 Gallons (5678 l)
0.75 gpm (2.8 l/m)
60 psi (4.2 kg/cm
o
68-70
F (20-21o C)
2
)
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the
substances listed below . The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the
permissable limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Table 1 Lead Reduction
Contaminant
Lead (pH 6.5) Lead (pH 8.5)
Average Influent
109500
Average Influent
1.9 mg/l
Average Influent
4666667
Average Influent
.153 mg/l .153 mg/l
Average Effluent
.00125 mg/l .001 mg/l
Average % Reduction
/
Minimum % Reduction
99.1/98.0
99.3/99.3
Maximum
Effluent
.003 mg/l .001 mg/l
Table 2 Cyst Reduction
Average Effluent
1
Maximum
Effluent
1
Units
particles/l
Average % Reduction
/
Minimum % Reduction
99.99/99.99
T able 3 Aesthetic Chlorine Reduction
Average Effluent
.05 mg/l
Maximum
Effluent .07 mg/l
Units
mg/l
% Reduction
97.3
Influent Challenge
Concentration
2.0 mg/l ±10%
T able 4 Particulate Reduction (Particle Size: 0.5 - 1 micron)
Average Effluent
45583
Maximum
Effluent
210000
Units
particles/ml
% Reduction
99.0
Influent Challenge
Concentration
min. 10,000 particles/ml
Influent
Challenge
Concentration .15 ± 10% mg/l .15 ± 10% mg/l
Influent Challenge
Concentration
minimum 50,000/ml
Reduction
Requirement
50%
Reduction
Requirement
85%
Max. Permissible
Product Water Concentration
.010 mg/l .010 mg/l
Reduction
Requirement
99.95%
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
FOR REPLACEMENT FILTER, PLEASE CALL 1.800.22ELKAY