Elkay LK4593FR Specifications

®
SPECIFICATIONS
GENERAL
Face-mounted, weather-resistant exposed stone aggregate fountain for year-round beauty with minimum maintenance. Contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents stand­ing waste water. Designed to be easily accessible to both physically challenged and able-bodied individuals. Ideally suited for installation in public areas. Models meets state and federal requirements as defined by the Americans with Disabilities Act.
Freeze-Resistant Valve System: Freeze-resistant system features box that installs behind non-freezing wall for housing water connection from the stop to the strainer.
THIS DRINKING FOUNTAIN COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Drinking Fountains are manufactured with a waterway system utilizing copper components and completely lead-free material. These waterways have no lead because all leaded materials, such as leaded brass, have been removed.
CONSTRUCTION
Bubbler: Vandal-resistant, bubbler is one-piece, chrome­plated with integral hood guard design to prevent contamina­tion from other users, airborne deposits and tampering.
Pushbutton Actuation Mechanism: Self-closing, vandal­resistant pushbutton does not require grasping or twisting.
Automatic Stream Height Regulator: Self-closing assembly is located inside unit to prevent tampering. Unit resists corro­sion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
Inlet Strainer: Easily cleaned in-line strainer screen traps par­ticles of 140 microns or larger before they enter the waterway.
Water Inlet: 3/8" O.D. tubing into freeze-resistant box. Drain Outlet: 1-1/4" waste outlet located in freeze-resistant
valve system.
Freeze-Resistant,
Barrier-Free Stone Fountain
Model LK4593FR
Model LK4593FR
This fountain is ADA compliant.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contoured-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be chrome-plated vandal-resistant type with integral hood guard and anti-squirt feature. Fountain shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the require­ments of NSF/ANSI 61/372, and the Safe Drinking Water Act.
Shipping Weight: 58 lbs.
This fountain is certified by WQA to lead-free compliance including NSF/ANSI 61 and 372.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2012 Elkay
(2/12) 19-19B
Freeze-Resistant,
®
(902mm)
35-1/2"
(387mm)
15-1/4"
HOLE (3)
MOUNTING
(11mm)
7/16"
Ø
WASTE LINE
(44mm)
1-3/4"
Ø
(25mm)
1"
Ø
WATER LINE
(22mm)
7/8"
(132mm)
5-3/16"
(12mm)
7/16"
(6mm)
1/4"
(740mm)
29-1/8"
(748mm)
29-7/16"
(98mm)
3-7/8"
(51mm)
2"
(76mm)
3"
(76mm)
3"
(327mm)
12-7/8"
(342mm)
13-7/16"
(483mm)
*ADA Requirement
19"
(864mm)
34"
(686mm)
27"*
BOX
RESISTANT
FREEZE
FINISHED FLOOR
FRONT VIEW / WALL LAYOUT SIDE VIEW
Barrier-Free Stone Fountain Model LK4593FR
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of freeze-resistant system and plumbing. For wall support required locations see installation instructions provided with fountain. Bolt fountain securely to wall per installation instructions. Water supply and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (See installation instructions for full details.)
Freeze-resistant box must be installed on interior non­freezing wall.
Service stop not included. CAUTION — Fountain must be securely bolted to wall. Operating Pressures: Supply water - 105 psi maximum.
NOTE: A service supply stop (not included) must be installed at the fountain inlet line.
ROUGH-IN DIMENSIONS
Elkay
19-19B (2/12)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2012 Elkay
Loading...