ECP8*1F
Refrigeration Package
INSTALLATION, CARE & USE MANUAL
INSTALLATION
1. Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is
within 1/2" (13 mm) of louver panel when panel is in place.
2. Water inlet is 3/8" (10 mm) O.D. unplated tube . Contractor to supply connections as required.
3. Connecting lines to be made of unplated copper. Thoroughly flush all lines to remove all foreign matter before
connecting to cooler.
4. Connect cooler to building supply with a shut-off valve and install a 3/8" (10 mm) unplated water line between
the valve and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches
a positive stop, approximately 3/4" (19 mm).
NOTE: DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE T O THE O-RINGS MA Y RESUL T .
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial
plate. Never wire the compressor directly to the power supply .
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure.
This grounding may be in the building, or may occur away from the building. This grounding can cause electrical
feedback into a water chiller, creating an electrolysis which causes a metallic t aste or an increase in the metal
content of the water. This condition is avoidable by using the proper materials indicated below. Drain fittings which
are provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady
stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
TROUBLE SHOOTING & MAINTENANCE
T emperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water , adjust screw
on item no. 5.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum
cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector .
Lubrication: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring
seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing.
To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.
WIRING DIAGRAM
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
98928C (Rev. A - 3/12)
ITEM NO.
1
2
3
4
5
6*
7
8
9
10
11
12
13
14
15
16
17
18
19
115V PARTS LIST
PAR T NO.
66810C
56237C
66576C
55996C
35839C
36322C
36173C
35768C
36167C
19037000
101516143550
100806740570
20282C
31490C
70018C
30664C
66703C
66743C
36208C
DESCRIPTION
EVAPORA TOR ASSY
SHROUD - FAN
HEAT EXCHANGER
STRAINER
COLD CONTROL
COMPRESSOR SERV . P AK
OVERLOAD
COVER RELAY
RELAY
CLIP - COMP MTG
STUD - COMP MTG
GROMMET - COMP MTG
BRACKET - F AN MTG
FAN MOTOR
NUT
FAN BLADE
DRIER
CONDENSER
POWER CORD
ECP8*1F
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY
REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL
ASSEMBLY .
NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF
THE ABOVE WATER COOLERS OR ORDERS FOR REPAIR
PARTS MUST INCLUDE MODEL NO. AND SERIAL NO. OF
COOLER, NAME AND PART NO. OF REPLACEMENT PART.
3
13
17
1
10, 1 1, 12
6
16
2
14, 15
7, 8, 9
4
5
ELKA Y MANUFACTURING COMP ANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
98928C (Rev. A - 3/12)
18
19
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620