Self-contained, electric refrigerated oor model water cooler. Capacity of 50°F drinking water, based upon 80°F inlet water and 90°F ambient. Cabinet design allows for ush to wall installation. Removable front panel and cabinet sides are Sandalwood Vinyl.
Non-Pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is subject to line pressure only when valve button is pressed.
Shall include the WaterSentry® VII 1500-gallon capacity lter, certied to NSF/ANSI 42 and 53. Unit shall be lead-free design which is certied to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• WaterSentry® VII 1500-gallon capacity Filtration System, certied to NSF/ANSI 42 & 53 (Lead, Class 1 Particulate, Chlorine, Taste & Odor)
• Extra deep basin minimizes splashing; with integral drain
• Exclusive Flexi-Guard® Safety bubbler
• Finish options: Impact-resistant vinyl coating or stainless steel
• Rated for Indoor use.
Series Flush to Wall Refrigerated
Filtered Water Cooler
Air Cooled Floor Mounted
Model LFDE10
RATED FOR INDOOR USE ONLY
COOLING SYSTEM
• Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is permanently lubricated.
• Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. Requirements for self extinguishing material. Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
CAPACITIES CHART
Model
LFDE10*(F)1Z 115V / 60Hz 9.8 GPH 6.8 535 68
LFDE10*(F)2YJO 220V / 50Hz 8.2 GPH 3.4 535 68
LFDE10*(F)3YJO 220V / 60Hz 9.8 GPH 3.4 535 68
`
*Color code of (L) Light Gray Granite or (T) Sandalwood or (S) Stainless Steel cooler wrapper. **Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied. (F) models are prepped for a glass ller (ordered separately).
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides structural
integrity
• Cooler cabinet available as Light Gray or Sandalwood Vinyl Clad Steel or Stainless Steel (additional cost) construction
• Exclusive Flexi-Guard® Safety Bubbler (option) utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact.
• Option for additional Glass Filler
REPLACEMENT FILTER:
• 51299C (single)
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever date falls rst.
ANSI/NSF 42 and 53
Certied
(Filter
only)
Ship
Wt.
UL399 and
CAN/CSA 22.2
No. 120
Certied
ANSI/NSF
61 and 372
Certied
++
++
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
SPEC08-02 (06/2014)
© 2014 Elkay
Open space rough-in design permits new installation or replacement of existing
Space-ette
Series Flush to Wall Refrigerated Filtered Water Cooler Air Cooled Floor Mounted Model LFDE10
fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below.
FRONT VIEW SIDE VIEW
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap, which is provided by the installer, should also be plastic to completely isolate the cooler from the building plumbing system.
LEGEND A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN C = 1-1/4 TRAP NOT FURNISHED D = POWER CORD 4 FEET (1219mm) LONG E = INSURE PROPER VENTILATION BY MAINTAINING 4” (102mm) (MIN.) CLEARANCE FROM
CABINET LOUVERS TO WALL. F = TO LEVEL UNIT, LOOSEN SCREWS TO ADJUST BASE FOR CONTACT WITH FLOOR. TIGHTEN SCREWS AFTER UNIT HAS BEEN LEVELED.
FINISHED FLOOR
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
Printed in U.S.A.
© 2014 Elkay