Space-ette®Series Flush to Wall Refrigerated
Water Cooler with WaterSentry®VII Filter System
S P E C IF I CAT I ON S
ENERAL
G
elf-contained, electric refrigerated floor model water cooler.
S
apacity of 50°F drinking water, based upon 80°F inlet water
C
nd 90°F ambient.
a
his model furnished with hermetically sealed combination
T
ank-tube type cooling unit enclosed in cabinet. Cabinet
t
esign allows for flush to wall installation. Removable front
d
anel and cabinet sides are Sandalwood Vinyl.
p
on-pressurized tank system is standard. Non-pressurized
N
ater tank is located after bubbler valve, so that tank is
w
ubject to line pressure only when valve button is pressed.
s
O LEAD DESIGN
N
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986
AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free
materials. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted.
®
WATERSENTRY
Elkay LFDE10 Water Coolers are equipped with the
WaterSentry VII Filter System. Tested to NSF/ANSI Standard
53 yields a reduction of soluble and in-soluble lead content to
less than 0.015mg/l. This translates to lead reduction levels of
93% to 99%. Class 1 particulate reduction as tested per
NSF/ANSI 42. Removes over 97.5% of free available chlorine
which provides Class 1 performance as tested to NSF/ANSI
42. Provides taste and odor improvement.
CAPACITIES CHART
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Lbs.
LF DE10 9.8 11.9 10.8 9.8 535 5.8 83
*Based on 80°F inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
VII FILTER SYSTEM
*GPH of 50°F Drinking Water
Room Temperature °F
Rated Load Wt.
Full Ship.
Air Cooled Floor Mounted
Model LFDE10
Model LFDE10
CONSTRUCTION
Cabinet: Cabinet wrapper supports fountain top and all working mechanisms. Removable front panel and cabinet sides
offer easy accessibility to interior.
Fountain Top: One piece stainless steel top polished to a uniform Elkay luster finish. Unique Swirl-Flo basin has an integral
vandal-resistant strainer, embossed bubbler pad.
®
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Antisweat. Keyed in location to prevent rotation.
Color Selection: Sandalwood is standard. Stainless steel is
available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 8-2H
12"
(305mm)
4-1/2"
(114mm)
12"
(305mm)
4"
(102mm)
TOP VIEW
SHUT OFF VALVE
(NOT FURNISHED)
WaterSentry® VII Filter System
SIDE VIEW FRONT VIEW
38"
(965mm)
3-1/2"
(89mm)
7/8"
(22mm)
4"
(102mm)
2"
(51mm)
12"
(305mm)
31-1/2"
(800mm)
29"
(737mm)
1-1/4" (32mm)
O.D. TAILPIECE
1-1/4" (32mm)
DRAIN STUB
OUT FROM
WALL 1" (25mm)
3/8" S.P.S. SUPPLY
STUB OUT FROM
WALL 1" (25mm)
1" (25mm)
4 FOOT (1.2M)
LONG POWER CORD
Space-ette®Series Flush to Wall Refrigerated
Water Cooler with WaterSentry®VII Filter System
Air Cooled Floor Mounted
Model LFDE10
MPORTANT!
I
INSTALLER PLEASE NOTE:
OTICE
N
This water cooler has been designed and built to provide
water to the user which has not been altered by materials
in the cooler waterways.
The grounding of electrical equipment such as telephone,
computers, etc., to water lines is a common procedure.
This grounding may be in the building but may also occur
away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis
which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by
installing the cooler using the proper materials as shown
below.
his water cooler must be connected to the water supply
T
sing a dielectric coupling. The cooler is furnished with a
u
on-metallic strainer which meets this requirement.
n
he drain trap which is provided by the installer should
T
lso be plastic to completely isolate the cooler from the
a
uilding plumbing system.
b
ROUGH-IN DIMENSIONS
Elkay
8-2H (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2011 Elkay