Elkay LBWD06XXK, LBWD00XXC User Manual

Page 1
ezH2O® Liv™
Built-in Filtered Water Dispenser
INSTALLATION, CARE & USER MANUAL
Page 2
Page 3
Contents
1.1 Installation, Care & User Manual ..........2
1.2 Disclaimer ............................2
1.3 Serial Number Location .................2
1.4 Contact Information.....................2
1.5 Notice of Changes .....................2
1.6 Models Covered in Manual ...............3
1.7 Radio Frequency Compliance.............3
1.8 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 General ..............................4
2.2 Safety Alert Symbol.....................4
2.3 Personal Safety........................4
2.4 Property Damage ......................5
3.1 General Information ....................5
4.1 Tools Required ........................6
4.2 Installer Supplied Parts Required ..........6
4.3 Critical Depth Dimensions................6
4.4 Mounting Height Dimensions .............7
4.5 Water Dispenser Installation ..............7
4.5.1 Installing Water Dispenser into the Wall 7
4.5.2 Installing the Filter Box..............8
4.5.3 Connecting the Water Lines.........10
4.6 Connecting the Optional Catch Basin Drain 10
4.7 Remote Filter Location .................12
4.8 Remote Water Chiller ..................13
5. Startup .................................13
6. Cleaning ................................14
7. Maintenance .............................14
7.1 Filter Cartridge Replacement ............14
8. Troubleshooting..........................16
9. Frequently Asked Questions (FAQ) ..........16
10. Wiring Diagram ..........................17
(630) 574-8484 1 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 4
1. General Information
WARNING
1.1 Installation, Care & User Manual
Read all instructions carefully BEFORE starting the installation and familiarize yourself with the various parts of this product.
This manual contains step-by-step installation, adjustment, and maintenance instructions for the Built-in Water Dispenser. Followed carefully, these instructions will result in an easy, trouble-free installation of this Elkay Manufacturing Company (Elkay) product. Additional use and care documents can be found on the Elkay website at http://www.elkay.com/support.
Any deviations, additions, or deletions from the described methods, without the prior written approval of our Customer Care department, will void the warranty covering this product.
Make sure the installation and use of this product meet all local, state, and federal plumbing and electrical codes.
Save these instructions for future reference.
1.3 Serial Number Location
Please use the serial number located on the inside right wall of the main enclosure, just above the junction box. Use this serial number when contacting us with questions concerning the installation of this product.
To avoid product or property damage, personal injury, or even possible death, carefully read,
understand, and follow all the instructions in this Installation, Care, & Use Manual before installing this product.
Improper installation, use, and/or maintenance of this product could cause a dangerous situation that results in injury or death.
Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals. Proper use of tools and the products described in this guide is your responsibility.
Failure to follow these instructions could result in personal injuries, water damage, and other damage
to oors, pipes, walls, and other portions of your
home.
1.2 Disclaimer
The information contained in this Installation, Care, & Use Manual is given free of charge. It is based upon technical data which we believe to be reliable and is intended for use by persons having knowledge of this technical area at their own discretion and risk. Elkay assumes no responsibility for results obtained or damage incurred from the use of this material either in whole or in part by the buyer.
1.4 Contact Information
General Information
Elkay Manufacturing Company 2222 Camden Court Oak Brook, IL 60523
Phone: 630.574.8484 Email: consumer@elkay.com Website: http://www.elkay.com
USA/Canada Customer Care
Phone: 800.476.4106 Email: CustCare@Elkay.com
International Customer Care
Phone: 630.575.4755 Email: IntlCare@Elkay.com
Installation Services
Phone: 800.952.8064 Email: installservice@elkay.com Website: http://www.elkay.com/contact-us/install
1.5 Notice of Changes
The information, specications, and illustrations in this
manual are based on the information that was available at the time this material was written and can change at any time.
Dimensions are given in inches (") and millimeters (mm).
Elkay Manufacturing Company 2 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 5
1.6 Models Covered in Manual
LBWD00xxC where xx represents color of facia/glass
LBWD06xxK where xx represents color of facia/glass
1.8 Warranty
This product is covered by a Limited Warranty and Elkay will not be held responsible for damage of any kind in connection with the installation of the product.
1.7 Radio Frequency Compliance
The water dispenser and lter communicate with each
other through a Near Field Communication (NFC) device. This short-range, wireless connectivity technology is
designed to monitor the status of the lter and to alert the user when it is time to change the lter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two (2) conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modications not approved by the
manufacturer could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Refer to the Elkay website http://www.elkay.com/warranty and click on DRINKING WATER PRODUCT WARRANTY
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de license. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 20 cm of the antenna, which may exceed the FCC radio frequency exposure limits.
(630) 574-8484 3 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 6
2. Safety
WARNING
THINK
SAFETY!
2.1 General
The Elkay Manufacturing Company (Elkay) cannot anticipate every possible circumstance that might involve a potential hazard during the installation or maintenance of this product. The warnings and instructions in this Installation, Care, & Use Manual are, therefore, not all-inclusive. If a tool, installation procedure, or work
method that is not specically recommended by Elkay is used, you must be satised that it is safe for yourself and
others. You should also make sure that the product will not be damaged by the methods you choose.
Most work-related accidents are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. As you install and maintain this product, you must be alert to potential hazards. You should also have the necessary training, skills, and tools to perform any installation or maintenance procedure.
2.2 Safety Alert Symbol
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
This manual contains WARNINGS, CAUTIONS, NOTICES, SAFETY INSTRUCTIONS, and NOTES which must be followed to prevent the possibility of improper service, damage to the equipment, personal injury, or death. The following keywords call the reader’s attention to potential hazards.
Hazards are identied by the “Safety Alert Symbol” and followed by a signal word such as “WARNING” or “CAUTION”.
Think Safety
Before performing any work, read and understand the safety instructions in this manual.
2.3 Personal Safety
These warnings indicate a potentially hazardous situation which, if not avoided, could result in serious injury or death. Follow all instructions related to the installation and/or maintenance of this product (unit).
Personal Protection Be sure to use all personal protective
equipment, such as sturdy safety glasses, work shoes, hearing protection, and cut resistant gloves, whenever necessary, to ensure your own safety.
To avoid eye injury, always wear protective glasses with side shields when using power tools. Also, make sure no one else
can be injured by ying particles when using
power tools.
Always wear ear protection, such as earmuffs or earplugs, when using power tools.
Wear protective cut resistant gloves during installation to protect against sharp edges from sheet metal components.
Power Tool Hazard
To prevent personal injury or possible death,
always follow the electrical safety recommendations of the power tool’s manufacturer.
• Do not use power tools in an unsafe manner.
• Power tools should only be connected to a circuit protected by a ground-fault circuit interrupter (GFCI).
• If an extension cord is required, always use an appropriate extension cord.
Shock and Electrocution Hazards
Failure to follow these instructions could result
in severe electrical burns, signicant injuries,
and even death.
Water will conduct electric current to create a short circuit, resulting in injury or death.
• Never use electric power tools around water or
wet oors/surfaces.
• Keep all liquids away from electrical cords and power tools.
• If an extension cord is required, always use an appropriate extension cord.
• DO NOT create a short circuit between a source of electricity and a liquid by being in contact with both simultaneously.
Elkay Manufacturing Company 4 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 7
WARNING
CAUTION
NOTICE
3. Installation Preparation
NOTICE
Contacting live electrical wiring with power tools or hand tools can cause serious injury or death.
• Make sure all related circuit breakers are turned OFF.
• Test for live circuits or wiring inside any wall where installation of the product requires cutting into a wall.
Prior to any maintenance, make sure the
unit is disconnected from the power source and the circuit breaker is turned OFF.
Prior to installation, test for live circuits or
wiring inside the wall before cutting or
drilling into the wall. Before working near any electrical circuit or wiring, remove all power and use a circuit tester to verify the power has been disconnected. Contact with live electricity can cause serious bodily injury and in some cases death.
These cautions indicate a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Follow all instructions related to installation and/or maintenance of this product.
Tripping Hazard Personal injury can result from tripping over power cords, tools, or other installation items.
DO NOT leave items laying around the work area.
Cutting Hazard The installation of this product requires using power tools.
Keep hands away from the cutting edge of any tool used in the installation of our product.
Placing ngers in or around the cutting blades
could result in serious personal injury.
Use Proper Tools Always use proper tools which are in good working condition during the installation of the
product.
The installation of this product requires electrical and
plumbing connections that use specic skills and knowledge. If you are unsure or not qualied to make these connections, consult a qualied plumber,
electrician, or installer for this installation. Professional installation is recommended.
3.1 General Information
1. This water dispenser is designed for indoor use only and should not be installed outdoors or in a humid environment. This water dispenser should not be installed on exterior walls.
NOTICE
water ow through the unit and damage to the
product. A pressure above 105 psi will also cause damage to the product.
2. Make sure the water supply pressure to the product is between 40 and 105 psi. The water dispenser with
lter requires 40 psi minimum water pressure.
3. Use care when opening and removing the packaging to prevent damage to the product.
a. Inspect the product for any shipping damage and
report it immediately to the location of purchase. Installation of a damaged product will void the warranty.
b. Conrm that all parts have been included for the
proper installation of this product. Contact the location of purchase if damaged parts are found.
NOTICE
drain water outlet pipes will be damaged during installation of the product. Damage to any of these
items can cause electrical damage, re, and/or water
damage.
4. Shut off the water supply source and disconnect power to the electrical circuit being used to operate the product before starting the installation.
A water supply pressure below 40 psi will result in decreased
Make sure no electrical wiring, potable water inlet pipes, or
2.4 Property Damage
Inspect Before Cutting Make sure no electrical wiring or plumbing is present before cutting into a wall.
(630) 574-8484 5 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 8
4. Installation
4.1 Tools Required
Tool Used For
Tape Measure Locate the mounting opening.
Wall Cutting Tool Remove section of wall to insert unit.
Level Proper mounting into the wall cavity.
Phillips Screw Driver Remove electrical box cover.
Various Electrician's Hand Tools
Various Plumber's Hand Tools
3/32 Allen Wrench Remove the front covers.
4.2 Installer Supplied Parts Required
#8 Flathead Screws 1-1/4" long. 8
12/2 with ground electrical wire (depending on local building codes the installation could require rigid conduit, armored cable, or plastic sheath NM-B cable).
Electrical wire nuts (appropriate size).
GFCI circuit (connected into an electrical circuit). 1
3/8" exible water tubing (copper or plastic) (insulated).
Quarter-turn shut off valve at the location of the water source.
1/4 inch copper or plastic tubing if a remote lter is
installed (insulated)
1-1/4" P-trap and related parts.
Plumbers Putty
Additional 3/4 inch drain hose if the installation requires a longer drain hose than the supplied 13-inch long hose.
Connecting power source to the unit's wiring.
Connecting unit's plumbing to the household water source and waste drain.
Description Qty.
Electrical
Water
15 feet or
Optional Catch Basin Drain
1
less
4.3 Critical Depth Dimensions
1. Make sure the wall cavity is deep enough to house the water dispenser (dimension A).
2. If the optional lter unit will be installed make sure there is adequate space to route electrical
wiring between the wall and the lter box which
is approximately 1-5/8" for standard 2 x 4 wall construction.
A
B
C
D
Water Dispenser
A) 3-7/8" (97 mm) deep. B) 19-7/8" (505 mm) high.
Filter Unit
C) 6-5/8" (169 mm) high. D) 2-3/8" (61 mm) deep.
Elkay Manufacturing Company 6 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 9
4.4 Mounting Height Dimensions
A
1. The suggested water dispenser mounting height to the center of the water dispenser sensor (C) is 47 inches (1194 mm). This height can be adjusted higher or lower depending on the desires of the user.
D
4.5 Water Dispenser Installation
There are several installation options available:
Water dispenser with attached lter box and lter.
Water dispenser with a remote lter.
Note: When the lter is located in a remote location, mount the lter vertically on a wall or other supporting
structure.
Water dispenser with remote lter and chiller.
Note: When the lter is located in a remote location, mount the lter vertically on a wall or other supporting
structure before the water chiller.
• Water dispenser with optional waste drain.
Use the following sections to install the water dispenser
using the appropriate conguration.
B
C
1
3
2
A
Plumbing and Electrical Key
1) P-trap. 2) 3/8 inch exible water tubing. (3) Electrical box.
Recommended Opening Dimensions
The overall wall opening is 14-1/2 inches (368 mm) wide (A) by 55-3/4 inches high (B), top of the unit to the oor. .
Unit Height (from oor)
B) 55-3/4 inches (1441 mm).
Height (from oor) to Bottle Filler Sensor
C) 47 inches (1194 mm).
Rough-in Reference Dimensions
D) 21-1/8 inches (537 mm) centerline of lter water inlet.
4.5.1 Installing Water Dispenser into the Wall
1. Cut the opening into the wall using the suggested mounting dimensions as a guide.
2. Place the unit into the wall cavity and slide it up against the drywall at the top of the opening. The unit is designed with 1/4 inch overlap to conceal any irregularities at the top of the wall opening.
Note Item 1: If the p-trap is sealed within the wall, under
the water dispenser, all the plumbing joints must be glued. The glue must be appropriate for the PVC pipe utilized. If the p-trap uses threaded components, they must be easily accessible.
Note Item 2: According to most electrical codes, the
electrical box cannot be sealed inside a wall cavity with no access. If the electrical connection is placed under the unit, a user-supplied removable wall cover will be required to access the junction box.
(630) 574-8484 7 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 10
A 1/4 inch offset helps conceal any irregularities at the top of the wall
NOTICE
opening.
3. Using a bubble level, level the water dispenser and
attach it to the wall studs using four #8 athead
screws.
CAUTION
regulations and standards when connecting any electrical device. A 15 AMP GFCI Circuit Breaker is required for safe installation.
5. Connect a 110 VAC power supply to the water dispenser. Route the wiring through the wall into the bottom of the electrical gang box.
a. Route the appropriate electrical wiring through a
wiring clamp into the gang box.
b. Tighten the wiring clamp to prevent the wire from
being pulled out of the gang box.
c. Connect black wire to supplied voltage line (black)
wire and the white wire to neutral.
d. Use installer provided wire nuts to insulate the
connections.
e. If required by code a green grounding screw can
be used to connect a grounding wire inside the gang box.
Follow all safety practices and industry
4. Locate the electrical gang box, at the lower right-hand corner of the water dispenser, and remove the cover.
f. Reinstall the gang box cover.
Do not use a cord with a three­prong plug to power this unit.
Note: If an optional filter unit will be installed under the
water dispenser, the space behind that filter box is limited so make sure any electrical wiring will not interfere with mounting the filter box into the wall. Refer to "4.3 Critical Depth Dimensions" on page 6 for additional information.
4.5.2 Installing the Filter Box
1. If the lter unit is being installed in the wall opening under the water dispenser, replace the front cover of
the water dispenser to help locate and align the lter
box under the water dispenser.
Elkay Manufacturing Company 8 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 11
NOTICE
It is recommended to attach the front cover with the top two
mounting screws to prevent it from falling away from
the water dispenser while the lter unit is being
installed.
3. Replace the lter unit cover and check the gap
between the two covers. Adjust the lter box to create
an even gap all the way across the units. Tighten all screws.
2. Place the lter unit into the wall opening and slide it up against the bottom of the water dispenser. Make sure
the lter unit is in alignment with the water dispenser and, using four #8 athead screws, start the screws to
hold the unit in place.
Do not completely tighten the screws until the lter unit cover is installed and the t between the water dispenser cover and the lter cover is checked.
Create an even gap across the entire unit.
4. After aligning the two sections, remove the front cover
from the lter unit by removing the four at head
screws from the right and left side of the cover using a 3/32 Allen wrench.
Note: Some side-to-side and up-and-down movement of
(630) 574-8484 9 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
the housing is capable to accurately align the filter unit with the water dispenser.
Page 12
4.5.3 Connecting the Water Lines
1. Connect the 1/4 inch water line from the water
dispenser to the lter housing.
2. Connect the NFC wire.
NOTICE
the top of the water dispenser. This connection has
been factory tested to be leak-free and could result in
water leaking into the unit if this connection is changed.
a. If the lter unit is installed below the water
dispenser, connect the 1/4 inch tube to the tting below the lter, as shown.
Do not disconnect the 1/4 inch
tubing from the water valve at
Note: Do not place the remote filter more than 15 feet
from the water dispenser.
3. Connect an installer supplied 3/8 inch water supply tube to the quarter-turn shutoff valve, as shown. The type of tubing, copper or plastic, should meet all local regulations and building codes.
Note: Elkay also recommends installing a shutoff valve
at the source of the water supply for the water dispenser.
4.6 Connecting the Optional Catch Basin Drain
The water dispenser does not require a drain connection to the household wastewater plumbing. The water dispenser has a built-in catch basin that will hold the
typical overow that can occur when using the product.
Some local building codes, however, may require a
wastewater drain to prevent the potential overow of
b. If the lter is installed in a remote location, attach
an installer supplied length of 1/4 inch tubing to the 1/4 inch tubing from the water dispenser using a union coupling. The type of 1/4 inch tubing, copper or plastic, should meet all local regulations and building codes. This line should be insulated to prevent condensation.
Elkay Manufacturing Company 10 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
water. The following steps cover the installation of the drain.
Page 13
1. Remove the two screws attaching the drain basin to the water dispenser. Remove the drain basin.
4. Install the O-ring over the strainer threads.
2. Place the drain basin on a at, hard surface, such
as a piece of sacricial wood. Carefully drill a hole
in the basin using a 1-inch hole saw using the centering-dimple as a guide to center the hole saw.
Note: Do not use a 1-1/8 inch hole saw as this will make
the opening too large.
3. Place a small amount of plumbers putty around the lip
of the strainer ange and insert it into the hole. If the ange does not t, carefully open the size of the hole.
5. Thread the strainer into the drain adapter. Needle-nose pliers can be used to turn the drain adapter. Tighten the connection to create a watertight seal. The drain adapter must be facing to the left.
(630) 574-8484 11 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 14
6. Attach one end of the 3/4 inch exible drain hose to the 3/4 inch barbed drain adapter connection using the
supplied hose clamp. The supplied exible drain is 13
inches long. If a longer drain hose is required, it must be installer-supplied.
7. Place the drain basin back into the water dispenser and reinstall the two screws.
10. Connect the drain adapter into the household waste drain pipe.
If the p-trap is located inside a sealed walled, it must have permanently-glued joints. If the p-trap is in an accessible location, a standard non-glued p-trap is acceptable.
Note: Whichever installation method is used, it must
meet local standards and building codes.
11. Install metal cover. Do not install the drip tray if the unit is plumbed into the household waste line.
4.7 Remote Filter Location
The lter unit can also be installed remotely, up to 15 feet away from the water dispenser. The remote lter location
is normally associated with the installation of a water chiller.
1. If desired, remove the lter unit from the lter box.
8. Route the drain hose through the lter box and attach the other end to the p-trap drain adapter using a hose clamp. The drain adapter is designed to be glued into a 1-1/4 inch PVC pipe.
9. Install the lter.
2. Securely mount the lter unit in the desired location.
Elkay Manufacturing Company 12 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 15
3. Connect a 3/8 inch water supply line, copper or
NOTICE
plastic, to the quarter-turn shutoff valve.
Follow the installation instructions that come with the
water chiller. A lter unit must also be installed prior to
the chiller, and the water line from the chiller to the water dispenser cannot be more than 15 feet long. When the
lter is located in a remote location, mount the lter
vertically on a wall or other supporting structure near the chiller.
4. Connect a 1/4 inch insulated water line, copper or
plastic, to the outlet connector of the lter.
5. Connect the 1/4 inch insulated water line to either a remote chiller or the 1/4 inch water line on the water
dispenser. Use a union connection tting to connect
the water line to the water dispenser.
Water
Filter
Water
Dispenser
Water Chiller
Note: The remote chiller can take from 24 to 48 hours to provide completely chilled water. Water lines must be insulated to prevent condensation.
5. Startup
1. Open the shutoff valve(s) for the water supply. Check for any water leaks.
2. Place the ON/OFF switch in the upper left-hand corner of the water dispenser opening in the OFF position. Turn ON power to the unit (typically a circuit breaker).
Do not disconnect the 1/4 inch
tubing from the water valve at
the top of the water dispenser. This connection has
been factory tested to be leak-free and could result in
water leaking into the unit if this connection is changed.
6. If a remote chiller is installed, follow the installation instructions provided with that unit.
4.8 Remote Water Chiller
A remote water chiller can be installed in connection with the water dispenser to supply chilled water. The chiller must be installed within 15 feet of the water dispenser, in an accessible location. Install the chiller with adequate ventilation space as outlined in the water chiller manual.
The standard installation of the built-in water dispenser
supplies ltered water at the ambient temperature of the
water supply that comes into the unit. This temperature can vary greatly depending on the location of the incoming water line.
(630) 574-8484 13 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
3. Move the power switch to the ON position and make sure the LED lights are lit.
4. Remove the scratch resistant protective layer that is
covering the glass face, lter cover, and back wall
covering.
Note: Not removing this layer will activate the IR sensor.
Page 16
5. Place a container under the water dispenser spout
to activate the ll sensor and dispense at least one
gallon of water to bleed off any trapped air from the
supply lines and lter as well as ush any ne carbon particles from the lter.
Note: The water dispenser is set to automatically shut off
after 16 ounces of water has been dispensed to
prevent overow and potential ooding so multiple
activations will be required to get the required one
gallon of water ow through the unit.
FILTER LIFE PLASTIC BOTTLES SAVED
9. Once the installation is complete, the water has been turned on, and any trapped air has been bled from the system re-check for any water leaks.
6. Cleaning
Warm, soapy water can be used to clean the exterior panels of the unit. Extra caution should be used to clean the glass cover panel. It can be easily scratched and should only be cleaned with mild soap and water or glass cleaner and a clean, soft cloth. Use of harsh chemicals (including bleach), petroleum-based, or abrasive cleaners will void the warranty.
Complete care and cleaning instructions can be found at http://www.elkay.com/care-and-cleaning and click on Drinking Water Products Care
6. If there are no leaks and the unit is functioning correctly, install the water dispenser cover and then
install the lter box cover using the athead screws
and a 3/32 inch Allen wrench.
7. Upon initial startup, the PLASTIC BOTTLES SAVED indicator panel should show several bottles have been saved due to the water used to initially start up the unit.
8. The left-most FILTER LIFE indicator light should also
be lit. This light shows the lter is functioning correctly
and has used less than 65 percent of its capacity.
When the middle blue light illuminates, the lter has
reached 66 percent of its life and will need to be changed soon. When this indicator light comes on, a replacement lter should be ordered.
The right-most red light will illuminate in red and
indicates that the lter should be changed.
For care of the outside surfaces of the water dispenser refer to the Elkay website http://www.elkay.com/
drinking-products-care
7. Maintenance
7.1 Filter Cartridge Replacement
A lter cartridge is designed to lter approximately 750
gallons of water at which time it must be replaced. The
lter should also be replaced every 12 months if the
750-gallon maximum is not reached.
1. Remove four screws from lter box cover using a 3/32
Allen wrench (if lter box is installed).
Elkay Manufacturing Company 14 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 17
2. Shut off the water supply using the shut-off valve. Turn water shut-off valve handle to the OFF position (clockwise). The handle will be facing up when closed.
3. Activate the water dispenser using a water bottle to relieve pressure in the water line.
4. Shut OFF power to the unit at the circuit breaker.
5. Place a towel inside the lter box, under the lter, to
absorb any water that leaks out of the lter when it is
removed.
6. Twist the lter counterclockwise until it is disengaged.
Remove the lter and quickly hold it upright.
7. Drain the lter before disposing of it in the trash. The
lter can be discarded along with the everyday trash.
8. Remove and discard the protective cap from the new
lter cartridge.
9. Mark the current date on the label of the new lter cartridge in the space provided.
10. Attach the lter cartridge by rmly inserting it onto
the lter head and twisting it clockwise until it is
completely seated. The label must be facing outward to be correctly installed.
11. Restore power to the unit at the circuit breaker.
(630) 574-8484 15 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 18
12. Check the lter status light. If the red light is blinking
the lter is installed incorrectly. A steady blue light indicates the lter is installed properly.
13. Open the water supply valve.
Note: The unit is set to automatically shut off after 16
ounces of water has been dispensed to prevent
overow and potential ooding so activations will
be required to get the needed one gallon of water
ow through the unit.
14. Place a container under the spout to activate the ll
15. Check for leaks.
sensor and dispense at least one gallon of water. This amount of water will bleed any trapped air from
16. Re-install the lter box cover.
the supply lines and lter as well as ush any ne carbon particles from the lter.
8. Troubleshooting
Description Possible Cause Remedy
Water is not getting cold. Standard water dispenser (non-
chilled)
Water chiller is not operating properly.
Water runs continuously from water dispenser.
Low water flow. Supply water pressure is less than
No water flow. No electrical power. Restore power to the unit.
Blinking red light. No filter. Replace filter.
Blinking red and blue light. Filter wire disconnected. Check filter cable connections.
Sensor is defective or dirty. Clean or replace sensor.
Solenoid or solenoid diaphragm is defective.
required.
Filter is plugged. Replace filter.
Solenoid water valve not opening fully.
Water shut-off valve(s) closed. Open all shut-off valves (one is located inside the filter box
Bottle sensor is not operating properly.
Blocked or damaged water line. Locate affected line and remove blockage or damage.
Filter incorrectly installed. Check filter is completely installed.
Standard unit only supplies ambient temperature water.
Refer to water chiller manual.
Replace solenoid water valve.
Note: To verify faulty solenoid, disconnect the power
while water is running. If water flow does not stop immediately then replace the solenoid.
Water pressure must be between 40 and 105 psi.
Replace solenoid water valve.
if installed and another may be at the water source).
Sensor is malfunctioning and must be replaced.
9. Frequently Asked Questions (FAQ)
For FAQ questions refer to the Elkay website
elkay.com/ezh2o-liv
Elkay Manufacturing Company 16 (630) 574-8484 Built-in Filtered Water Dispenser 1000005232 (Rev. C - 05/19)
Page 19
10. Wiring Diagram
Water Dispenser
Main
Control Board
Alcove LED's
IR Board
NFC filter board
ON/OFF
switch
Molex
connector for
extension cable
RS232 comm
Water valve
120VAC
120VAC
120VAC
Electrical Box
(inside water dispenser)
Electrical Line IN
3.3 volts
RS232 comm
Extension cable for NFC board:
Can be 18 inches for local use OR 18 ft for remote use.
Built-in Filtered Water Dispenser
Wiring Diagram
Ferrite Bead
Mfr: Fair-Rite
Part # 0443167251
(630) 574-8484 17 Elkay Manufacturing Company 1000005232 (Rev. C - 05/19) Built-in Filtered Water Dispenser
Page 20
Loading...