Elkay EWHA14 User Manual

OLD STYLE HOT WATER TANK
USED ON MODELS EWHA AND EFHA
TO DRAIN
CUT
CUT
EWHA SHELF TOP VIEW
INSTALL PLASTIC BUSHING IN THIS HOLE.
HOT WATER OUTLET TUBE (ITEM 11) PASSES
THRU SHELF HERE, U SHAPE OF TUBE
MUST BE BENEATH SHELF.
FRONT
DRILL .154 DIA. (No. 23) HOLE USE BRACKET (ITEM 9) TO LOCATE HOLE.
EXISTING HOLE
9
HOT TANK
DRAIN
WATER IN
FROM VALVE
HOLES
SIDE PANEL
EFHA BACK VIEW
HOT WATER
OUT TO VA LVE
10
3
3
FAN ASSY.
SIDE PANEL
EVAPORATOR
PAGE 1 97945C (Rev. SI- 11/02)
NEW STAINLESS STEEL
HOT WATER TANK KIT
( EWHA SHOWN )
2
HOT TANK SWITCH
HOT WATER OUT
WATER IN
VENT
5
11
5
6
WATER TO
HOT TANK
7
9
3
10
1
8
TO HOT TANK
HEATER ELEMENT
GROUND
COLD CONTROL
COMPRESSOR
4
3
ELKAY HOT TANK REPLACEMENT INSTRUCTIONS
1. Disconnect electrical power to the water cooler and shut off water to the unit.
2. Remove the necessary panel(s) to gain access to the hot tank.
3. Drain the hot tank by removing the drain plug from the bottom of the tank.
4. Refer to the drawing of the old style hot tank to cut the water tubes that are connected to the hot tank in the locations shown.
5. Remove and discard the power cord from the unit by disconnecting from the compressor, cold control, and the hot tank.
6. Remove the hot tank.
7. Install new hot tank per location shown on page 1 for model being serviced. EFHA models must be pulled away from wall to mount hot tank from back.
8. Route the hot valve tubes to the hot tank and connect using the gray quick connect water fittings. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximateley 3/4. To remove tubing from the fitting, relieve water pressure and push in on gray collar while pulling on the tubing.
9. Using the supplied power cord, re-wire the unit as shown in the drawing above. Jumper wire (Item 12) routed from switch to hot tank thermostat. Cut terminals off the fan motor and replace with supplied terminals (Item 13). Route fan motor leads to compressor and attach ribbed lead to the relay and the smooth lead to the overload. Connect power cord leads to the fan motor terminals (ribbed to ribbed, smooth to smooth). Route wiring away from fan blade and hot surfaces using supplied tie wrap.
10. On EFHA models place unit back into original position and reconnect water and drain tubes.
11. Turn on the water supply and fill the hot tank with water by depressing the hot valve. CHECK FOR LEAKS.
12. Plug the unit in, making sure the compressor and fan run and the hot tank produces hot water.
13. Replace panels.
PRINTED IN U.S.A.
ITEM NO.
1
2
3 4 5 6 7 8
9 10 11
12 (NS)
13 (NS)
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523  630.574.8484
QTY. DESCRIPTION
1
HOT TANK ASSY (115V)
1
HOT TANK ASSY (220V)
1
POWER CORD (115V)
1
POWER CORD (220V)
5/6
SCREW #10 X .50 HHSM
1
TUBE - CU 1/4 X 12.00
2
UNION - 1/4
1
ELBOW - 1/4
1
ELBOW - 3/8 X 1/4
1
PLUG - DRAIN
1
BRACKET - HOT TANK MNTG.
1
BRKT - HOT TANK ASSY. MNTG.
1
TUBE - HOT WATER OUTLET
1
JUMPER WIRE (FOR SWITCH TO HOT TANK THERMOSTAT)
2
CONNECTOR - PIGGYBACK
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 297945C (Rev. SI- 11/02)
EFHA8 & 14
PART NO.
36154C 36155C 36132C 36134C 70002C 62177C 70683C 70793C 70863C 70606C
--
28374C
--
31392C
31500C
EWHA8 & 14
PART NO.
36154C 36155C 36132C 36134C 70002C 62177C 70683C 70793C 70863C 70606C 28366C 28367C 66726C 31392C
31500C
Loading...