S P E CI F IC AT I O N S
ENERAL
G
Self-contained, electric refrigerated, wall hung water cooler.
Capacity of 50°F drinking water, based upon 80°F inlet water
and 90°F ambient.
Non-pressurized tank system is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is
subject to line pressure only when valve button is pressed.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986
AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free
materials. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted. A strainer with an easily cleanable screen is provided to allow trapping and convenient removal of waterborne
particulate of 140 microns and larger prior to their entry into
the water cooler.
CAPACITIES CHART
GPH of 50°F Drinking Water
*
oom Temperature °F
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Cooler Lbs.
††
EWA 4 4.0 4.8 4.4 4.0 230 2.5 Yes No 66
††
EWA 8 7.6 9.2 8.4 7.6 370 4.0 Yes No 69
††
EWA 14 13.5 16.3 14.9 13.5 665 7.2 Yes No 72
††
EWA 16 9.6 18.8 17.1 15.5 510 5.5 Yes Yes 76
††
EWA 20 12.0 23.6 21.5 19.5 665 7.2 Yes Yes 74
*Based on 80°F inlet water temperature.
•Pre-cooler capacities based on 60% spill through pre-cooler.
†Glass filler available at extra cost. Requires factory preparation to receive glass
filler.
††EWA16 and EWA20 meet only the lead-free definition of NSF/ANSI 61.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
R
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins.
(EWA4 has steel tube with steel fins.) Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for
altitude requirement.
Full Glass† Ship.
Rated Load Filler •Pre- Wt.
No Lead Wall Mount Water Cooler
Air Cooled – Models EWA4, EWA8,
EWA14, EWA16 and EWA20
Model EWA4
CONSTRUCTION
Fountain Top: One piece stainless steel top, polished to a
uniform Elkay bright luster finish. Exclusive Cascade basin
tested most splash-resistant, features multi-level deck design
with a built-in vandal-resistant strainer.
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Antisweat. Keyed in location to prevent rotation.
Removable Panel: Removable front panel offers easy accessibility to interior. Cabinet design allows for flush to wall
mounting.
Color Selection: Models available in Light Gray Granite,
Almond, Sandalwood and Stainless Steel panels.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 10-8I

No Lead Wall Mount Water Cooler
C
L
5"
(127mm)
3/4"
(19mm)
17"
(432mm)
29-1/2"
(749mm)
1-1/4" (32mm)
O.D. TAILPIECE
RECOMMENDED LOCATION
3/8" I.P.S. COLD WATER SUPPLY
(STUB OUT FROM WALL 1")
WASTE OUTLET – 1-1/4" I.P.S.
(STUB OUT FROM WALL 1")
1"
(25mm)
1-3/8"
(35mm)
4-1/8"
(105mm)
14-1/2"
(368mm)
18"
(457mm)
5/16" (8mm) DIA. SCREW HOLES
IN MOUNTING PLATE
3/4"
(19mm)
5-7/16"
(138mm)
7/8"
(22mm)
2-1/2"
(64mm)
40" (1016mm) - ADULTS
33" (838mm) - CHILDREN
OPTIONAL
ELECTRICAL OUTLET
LOCATION
ELECTRICAL OUTLET
(BY OTHERS)
1-1/2 FOOT (457mm) LONG
POWER CORD
14-1/2"
(368mm)
WALL LINE
1-1/4" (32mm)
O.D. TAILPIECE
(TRAP NOT FURNISHED)
3/8" O.D. TUBE
CONNECT
COLD WATER
SUPPLY BY OTHERS
11- 1/ 16"
(281mm)
4-5/8"
(117mm)
TANK DRAIN
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
B
UILDING WATER
I
NLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
B
UILDING WATER
I
NLET
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
Air Cooled – Models EWA4, EWA8,
EWA14, EWA16 and EWA20
TOP VIEW
ROUGH-IN DIMENSIONS
MPORTANT!
I
NSTALLER PLEASE NOTE:
his water cooler has been designed and built to provide water to the user which has
T
ot been altered by materials in the cooler waterways.
n
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes an
increase in the metal content of the water. This condition is avoidable by installing the
cooler using the proper materials as shown below.
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
he drain trap which is provided by the installer should also be plastic to completely
T
solate the cooler from the building plumbing system.
i
I
NOTICE
Elkay
10-8I (Rev. 4/11)
FRONT VIEW
2222 Camden Court
Oak Brook, IL 60523
SIDE VIEW
Printed in U.S.A.