Elkay EFRC8C-A, EFRC8CDC-A, EFRC12C-A, EFRC12CDC-A, LJNE8C-A Installation, Care & Use Manual

...
Page 1
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
Installation/Care/Use Manual
Fully Recessed Refrigerated
Fountain with FLEXI-GUARD
23
®
24
SEE FIG. 9
SEE FIG. 7
SEE FIG. 8
19, 22
25
20, 21
SEE FIG. 11
SEE FIG. 9
EFRC8C, EFRC12C EFRC8CDC, EFRC12CDC
Installer
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
97162C (Rev. H - 10/02)PAGE 1
Page 2
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
EFRC8C/EFRC12C ROUGH-IN
FINISHED FLOOR LINE
FIG. 1
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES).
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN (BOTH SIDES).
C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).
NOTES:
1. THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX. USE SIX SCREWS OR BOLTS (NOT PROVIDED).
97162C (Rev. H - 10/02) PAGE 2
Page 3
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
EFRC8CDC/EFRC12CDC ROUGH-IN
FINISHED FLOOR LINE
FIG. 2
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (LEFT SIDE ONLY).
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN (LEFT SIDE ONLY).
C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).
*WATER AND DRAIN CONNECTIONS MUST BE MADE FROM LEFT SIDE ONLY.
NOTES:
1. THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX. USE SIX SCREWS OR BOLTS (NOT PROVIDED).
97162C (Rev. H - 10/02)PAGE 3
Page 4
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
INSTALLATION INSTRUCTIONS
1. Remove shipping brace from mounting box and discard.
2. Fasten mounting box into wall cutout using screws or bolts (provided by others) through the holes or knock
outs provided on each side of the mounting box. (See Fig. 1 or 2)
3. Install fountain body to mounting box using #10 x .63 (16mm) PHSM screws and large clips provided.
4. Place refrigeration package into mounting box and connect water lines. (See Page 5 for details)
5. Water inlet is 3/8" O.D. and waste tube is 1-1/4" O.D. Contractor is to supply waste trap and service stop
valve in accordance with local codes.
6. Connecting lines to be unplated copper and thoroughly flushed to remove all foreign matter before connecting to refrigeration package. The furnished strainer (Item 18) should be added to the supply line.
7. Connect the refrigeration package to the supply line service stop valve. Connect supplied fountain (internal plumbing) tubes as shown in figures 3, 4, 5, or 6. Remove any burrs from water tubes before inserting into fittings. (See Figs. 13 and 14) DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE
TO THE O-RINGS MAY RESULT.
8. Electrical: Insure power supply is identical in voltage, hertz, and phase to that specified on the refrigeration
package serial plate. Never wire compressor directly to the power supply.
9. Turn water supply on and check thoroughly for leaks.
10. Release air from tank by depressing push button; a steady stream of water assures all air is removed.
11. Re-check for leaks.
12. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, turn adjustment screw on
regulator (Item 14). Clockwise adjustment will raise the stream height and counter-clockwise adjustment will lower stream height. For best adjustment, stream should hit basin approximately 6-1/2" from the bubbler.
13. Rotate fan blade on refrigeration package to insure proper clearance and free fan action.
14. Connect power supply.
15. Install grill using #8 x 1.00" (25mm) PH screws and small clips provided.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from orifice with a small round file not over 1/8 diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.
2. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 13). To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximatley 3/4".
97162C (Rev. H - 10/02) PAGE 4
Page 5
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
18
44
44
17
EFRC8C EFRC8C W/GLASS FILLER
FIG. 3 FIG. 4
18
44
16
18
44
17
17
17
16
18
17
EFRC12C EFRC12C W/GLASS FILLER
FIG. 5 FIG. 6
97162C (Rev. H - 10/02)PAGE 5
Page 6
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
5
12
10
11
13
BASIN
15
NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHEN NUT (ITEM 15) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER
TIGHTEN.
4
1
14
6
BASIN
9
FIG. 8FIG. 7
28
3
30
33
7
28
32
8
34
2
FIG. 9
97162C (Rev. H - 10/02) PAGE 6
Page 7
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
42
FIG. 10
43
15
26
15
27
DISPENSER/
DISPOSAL
26 29
31
16
FIG. 11
17
36
41
38
35
39
40
37
FIG. 12
97162C (Rev. H - 10/02)PAGE 7
Page 8
EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
PARTS LIST
ITEM NO. PART NO. DESCRIPTION
1 2
3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
15005C 20397C 40301C 40480C 40561C 40038C 40048C 40089C 40169C 40619C 50074C 50986C 56073C 40322C 56011C 55997C 61313C 75580C 70682C 70683C 55996C
110669443890
74070030 74070032
70567C
55001084
EFRCDF
55000881
EG23
31525028
40493C 40299C 40562C 50258C 50967C 61099C 70151C 70234C 22940C 51294C 51299C 70792C 70818C 70822C 70823C 62084C 62088C 56092C
Retaining Nut Tailpipe - EFRC8, EFRC8F Tailpipe - EFRC8CD Precooler - EFRC12, EFRC12F Precooler - EFRC12CD Strainer Button Nut - Cover Hex Nut Ferrule Gasket Regulator Holder Bubbler Assy Orifice Assy Housing Assy Pedestal Regulator Locknut - 3/8-18 Tee - 1/4 Union - 1/4 Strainer Screw - #10 x .63 PHSM Screw - #8 x 1.00 PH Speed Nut - #8 Clip - Speed Fountain Fountain - GF Dispenser/Disposal Grill O-ring Glass Filler Drain - 1/2 Glass Filler Washer Flow Regulator Assy Connector Assy Washer Hose Clamp Bracket - Filter Mounting Filter Head Assy Filter Assy Screw - #8-18 x .75 PH Elbow - 3/8 (10mm) Fitting - Superseal 1/4 ((8mm) Fitting - Superseal 3/8 (10mm) Tube Assy - GF Tube Assy - GF Poly Tubing 48(Cut to Length)
NOTE: REMOVE ANY BURRS FROM WATER TUBES BEFORE INSERTING INTO FITTINGS.
FIG. 13
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
FIG. 14
www.DrinkingFountainDoctor.com 800-518-5388
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523
97162C (Rev. H - 10/02) PAGE 8