EDFP A17C*A EDFP A17RAC*A EDFP A VR17C*A EDFP A VR17RAC*A
Installation/Care/Use Manual
Non-Refrigerated Fountains with FLEXI-GUARD
23
EDFPA17C EDFPA17RAC
Installer
T o assure you install this model easily and correctly , PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE ST ARTING THE INST ALLATION. CHECK YOUR INST ALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
SEE FIG. 7 OR 8
®
24
SEE FIG. 11
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. T O
WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y
OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A
FOUNT AIN, CREATING AN ELECTROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN
THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER
MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPL Y
29
NOTE: WA TER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 1 FIG. 2
97703C (Rev. E - 3/05)
EDFP A17C *A EDFP A17RAC*A EDFP A VR17C*A EDFP A VR17RAC*A
EDFP A17C
LEGEND
A = RECOMMENDED WA TER SUPPL Y LOCA TION 3/8 O.D. E = 5/16" (8mm) DIA HOLES FOR MOUNTING HANGER
UNPLATED COPPER TUBE CONNECT STUBBED 1" (25mm) T O WALL
FROM WALL SHUT OFF BY OTHERS F = WALL HANGER FURNISHED LOOSE
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/4" G = 1/4" (6mm) DIA. HOLES FOR SECURING FOUNTAIN
O.D. DRAIN. SEE FIG . 10, P AGE 8 FOR DET AILS
C = RECOMMENDED LOCA TION FOR W ASTE OUTLET 1-1/4"
O.D. DRAIN STUBBED 6-3/4" (171mm) FROM THE WALL
D = 1-1/4" TRAP FURNISHED
97703C (Rev. E - 3/05)
FIG. 3
NOTE: REINFORCE WALL IN SHADED AREAS
PAGE 2
EDFP A17C*A EDFP A17RAC*A EDFP A VR17C*A EDFP A VR17RAC*A
EDFP A17RAC
LEGEND
A = RECOMMENDED WA TER SUPPL Y LOCA TION 3/8 O.D. E = 5/16" (8mm) DIA HOLES FOR MOUNTING HANGER
UNPLATED COPPER TUBE CONNECT STUBBED 1" (25mm) T O W ALL
FROM WALL SHUT OFF BY OTHERS F = WALL HANGER FURNISHED LOOSE
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/4" G = 1/4" (6mm) DIA. HOLES FOR SECURING FOUNTAIN
O.D. DRAIN. SEE FIG . 10, P AGE 8 FOR DET AILS.
C = RECOMMENDED LOCA TION FOR W ASTE OUTLET 1-1/4"
O.D. DRAIN STUBBED 6-3/4" (171mm) FROM THE WALL
D = 1-1/4" TRAP FURNISHED
FIG. 4
PAGE 3
NOTE: REINFORCE WALL IN SHADED AREAS
97703C (Rev. E - 3/05)