Elkay EDFP217C Specifications

No Lead Two-Level Drinking Fountain Soft Sides
S P E C I F I C AT I O N S
GENERAL
Two-level wall mounted drinking fountain constructed of #18 gauge, type 304, stainless steel polished to a lustrous satin finish.
Contoured basin minimizes splashing and has exclusive Flexi-
®
Guard Keyed in location to prevent rotation. Easy to operate, fully functional push-buttons are vandal-resistant. Vandal-resistant bottom cover plates included. Flow regulator provides constant stream from 20 to 105 psi water pressure.
THIS DRINKING FOUNTAIN COMPLIES WITH THE REQUIREM ENTS OF A.D.A. (AMERICANS WITH DIS­ABILITIES ACT) WHEN PROPERLY INSTALLED. UNIT IS COMPLIANT IF INSTALLED IN AN ALCOVE AND IS ALSO COMPLIANT WHEN MOUNTED ON AN EXPOSED WALL IF A WING WALL IS LOCATED ON THE LEFT SIDE OR IF A 97258C APRON IS INSTALLED UNDER THE UPPER UNIT.
NO LE
THIS DRINKING FOUNTAIN COM PLIES WITH THE LEAD­FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAM INATION CONTROL ACT OF
1988.
Elkay Drinking Fountains are manufactured with a waterway system utilizing copper components and completely lead-free material. These waterways have no lead because all leaded materials, such as leaded brass, have been removed.
This fountain is certified by WQA to lead-free compliance including NSF/ANSI 61 and 372.
CONSTRUCTION
EDFP217C furnished complete with Flexi-Guard assembled front push-buttons, flow regulator (20 to 105 psi), and drain, trap assemblies and vandal-resistant bottom cover plates.
safety bubbler to prevent accidental mouth injuries.
AD DESIGN
®
, fully
Wall Mount-Fully Exposed with Wall Plate
Barrier-Free Access Model EDFP217C
Model EDFP217C Shown
ALSO AVAILABLE
Model EDFPVR217C: Includes vandal-resistant bubblers. Heavy-duty, one-piece construction, chrome plated
Model EDFP217FC: Plumbed for use with glass filler. Long fountain arm only. LK1110 or LK1114 sold separate.
Model EDFP217FPK: Freeze-resistant model with boxes (see separate specification sheet).
ACCESSORIES
MP20 Surface mounting plate. MPW200 In-wall carrier mounting plate. ML100 Support columns for MPW200.
brass.
®
(978mm)
(97mm)
(42mm)
(152mm)
(1003mm)
In keeping with our polic y of continuing prod uct improvement, Elkay reserves t he right to change produc t specifications wit hout notice. Please visit elkayusa.com for most current version of the
Elkay
elkayusa.com
(308mm) (308mm)
(168mm)
FINISHED FLOOR
2222 Camden Court Oak Brook, IL 60523
ADA REQUIREMENT
(476mm)
(330mm)
(41mm)
(518mm)
(165mm)
This specification describes an Elkay produc t wit h design, q uality and funct ional benefits t o the user. When making a com parison of other prod ucers’ offerings, b e certai overlooked.product specification sheet.
Printed in U.S.A. ©2012 Elkay
(Rev. 9/12) 14-27G
(57mm)
(57mm)
n these features are not
(16mm)
TION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
VICE STOP
NOT FURNISHED)
3/8" O.D. TUBE CONNECT
1/4" O.D. TUBE
BUILDING W
No Lead Two-Level Drinking Fountain Soft Sides Wall Mount-Fully Exposed with Wall Plate Barrier-Free Access Model EDFP217C
RELEASE TUBE AB
C
TUBE TO ATTACH
IN POSITION
TO RELEASE TUBE SIMPLY PUSH IN
TUBE IS SECURED
PUSH IN COLLET
( DIRECTION
OPERA
SER NOTE: WATERFLOW
3/8" O.D. UNPLATED COPPER TUBE. MATERIAL. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT ARE MANUFACTURED OF COMPLETELY LEAD FREE AND VALVE INCLUDING ALL CONNECTING FITTINGS WHICH
INLET
TO COOLER
COLD WATER SUPPLY THIS DRINKING FOUNTAIN IS FURNISHED WITH A BUBBLER
ATER
WATER INLET
INSTALLER NOTE
INSTALLER NOTE
THIS DRINKING FOUNTAIN IS FURNISHED WITH A BUBBLER AND VALVE INCLUDING ALL CONNECTING FITTINGS WHICH ARE MANUFACTURED OF COMPLETELY LEAD FREE MATERIAL. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
®
R O U G H - I N D I M E N S I O N S
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
A B
NOTE: Reinforce the wall in the shaded areas to support up to 300 lbs. static load.
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
C
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
WALL ROUGH-IN
NOTE: WATERFLOW
DIRECTION
SERVICE STOP (NOT FURNISHED)
NOTE: When using MP20 Surface Mounting Plate, remove the wall hanger and back panel channels. See separate specification sheet for details on MP20 Surface Mounting Plate.
LEGEND A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED D = 1-1/4" TRAP FURNISHED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM E = 3/8" (10mm) DIA. HOLES FOR SECURING WALL SHUT OFF BY OTHERS FOUNTAIN TO WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET F = 3/8" (10mm) DIA. SLOTS FOR MOUNTING 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL HANGER TO WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET G = WALL HANGER FURNISHED LOOSE 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL
Elkay
14-27G (Rev. 9/12)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2012 Elkay