Elkay EDFP217C, EDFP217RAC User Manual

EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC
Installation/Care/Use Manual
Soft Sides™ Fountains with FLEXI-GUARD
EDFP217C EDFP217RAC
®
Installer T o assure you install this model easily and correctly , PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE INST ALLATION. CHECK YOUR INST ALLA TION FOR COMPLIANCE WITH PLUMBING , ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
FIG. 2FIG. 1
97705C (Rev. J - 8/07)
EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC
EDFP217C
LEGEND A = RECOMMENDED W A TER SUPPLY LOCATION 3/8 O.D. UNPLA TED D = 1-1/4" TRAP FURNISHED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM E = 3/8" (10mm) DIA. HOLES FOR SECURING WALL SHUT OFF BY OTHERS FOUNTAIN TO WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET F = 3/8" (10mm) DIA. SLOTS FOR MOUNTING 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL HANGER T O WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET G = W ALL HANGER FURNISHED LOOSE 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL
NOTE: REINFORCE THE WALL IN THE SHADED AREAS.
97705C (Rev. J - 8/07)
FIG. 3
PAGE 2
EDFP217C*B EDFP217RAC EDFPVR217C EDFPVR217RAC
EDFP217RAC
LEGEND A = RECOMMENDED W A TER SUPPLY LOCATION 3/8 O.D. UNPLA TED D = 1-1/4" TRAP FURNISHED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM E = 3/8" (10mm) DIA. HOLES FOR SECURING WALL SHUT OFF BY OTHERS FOUNTAIN TO WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET F = 3/8" (10mm) DIA. SLOTS FOR MOUNTING 1-1/4" O.D. DRAIN STUBBED 1-1/2" (35mm) FROM THE WALL HANGER T O WALL C = RECOMMENDED LOCATION FOR WASTE OUTLET G = W ALL HANGER FURNISHED LOOSE 1-1/4" O.D. DRAIN STUBBED 6-3/4" (168mm) FROM THE WALL
NOTE: REINFORCE THE WALL IN THE SHADED AREAS.
FIG. 4
PAGE 3
97705C (Rev. J - 8/07)