Elkay EDFP210FPC, EDFP217FPC, EDFP214FPC User Manual

EDFP210FP*B EDFP214FP*B EDFP217FP*B
Installation/Care/Use Manual
EDFP210FPC EDFP214FPC EDFP217FPC
Soft Sides
EDFP210FPC EDFP217FPC
Freeze Resistant Fount ains
EDFP214FPC
Installer T o assure you install this model easily and correctly , PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE INST ALLA TION. CHECK YOUR INST ALLA­TION FOR COMPLIANCE WITH PLUMBING , ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s) contains the Freeze Resistant Package(s) LKFRB1 that are installed on an interior heated wall. The interior space must maintain a minimum temperature of 50° F (10° C). Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
97565C (Rev. J - 8/07)
EDFP210FP*B EDFP214FP*B EDFP217FP*B
FINISHED FLOOR
EDFP210FP/EDFP214FP
MOUNTING BOLT AND ACCESS HOLE LAYOUT
FIG . 1
97565C (Rev. J - 8/07)
PAGE 2
LEGEND
A = MOUNTING BOL T LOCA TIONS
(4) (3/8" DIA. NOT PROVIDED)
B = 7/8" DIA. (22mm) HOLE FOR
WATER SUPPLY TUBE
C = 7/8" DIA. (22mm) HOLE FOR
OPERA TING CABLE
D = 1-3/4" (44mm) HOLE FOR
WASTE LINE
EDFP210FP*B EDFP214FP*B EDFP217FP*B
ROUGH-IN DRA WINGS
EDFP210FP/EDFP214FP
FIG . 2
FINISHED FLOOR
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (not provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
PAGE 3
97565C (Rev. J - 8/07)
EDFP210FP*B EDFP214FP*B EDFP217FP*B
FINISHED FLOOR
EDFP217FP
MOUNTING BOLT AND ACCESS HOLE LAYOUT
FIG . 3
97565C (Rev. J - 8/07)
PAGE 4
LEGEND
A = 3/8" DIA. (10mm) SLOTS (FOR MOUNTING
UPPER HANGER BRACKET)
B = 7/8" DIA. (22mm) HOLE FOR WA TER
SUPPLY TUBE
C = 7/8" DIA. (22mm) HOLE FOR OPERA TING
CABLE
D = MOUNTING BOL T LOCA TIONS (8) (3/8" DIA.
NOT PROVIDED)
E = 1-3/4" (44mm) HOLE FOR WASTE LINE
EDFP210FP*B EDFP214FP*B EDFP217FP*B
EDFP217FP
ROUGH-IN DRA WINGS
FIG . 4
FINISHED FLOOR
PAGE 5
1. Wall should already be framed for the fountains using dimensions shown in Fig. 3. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom covers from fountains and save the screws.
3. Install the fountains using bolts and washers (not provided). Tighten securely.
4. Attach drain tubes to fountains and cut to required length using the freeze resistant boxes as guides.
5. Install freeze-resistant boxes - see box instructions.
6. Replace bottom covers.
97565C (Rev. J - 8/07)
EDFP210FP*B EDFP214FP*B EDFP217FP*B
CABLE SHEA TH ADJUSTMENT
T o Increase Free Play
T o Reduce Free Play
FIG . 5
FIG . 6
See Fig. 9
97565C (Rev. J - 8/07)
See Fig. 5
FIG . 8
FIG . 7
FIG . 9
PAGE 6
EDFP210FP*B EDFP214FP*B EDFP217FP*B
The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted. If recess mounted the surface of the cover must be flush with the interior wall surface. The package is furnished with screws for mounting the cover to the box. If the box is recess mounted, do not fasten the top and bottom of the cover to the box. Use the holes on the front only .
1. Assemble the operating cable to the fountain bracket. (Fountain should be mounted to exterior wall) Create a loop in the cable and thread the free end of the cable through the wall into the freeze resistant box. The adjustment nuts should be in the middle of threaded area on the operating cable. See Figure 9
2. Connect free end of operating cable to the valve-operating bracket. The end of the cables must be recessed into the indents on the pivot brackets.
3. Remove cable free play by adjusting the jam nuts on the ends of the operating cable. See Figure 6
4. Connect water line from fountain bubbler into freeze resistant box. The connection to the box uses a quick connect water fitting. Position the water line, in the fountain, to drain back into interior mounted box. Any water left standing, in the exterior line, can freeze.
T o insert tubing, push tube straight into fitting until it reaches a positive stop. T o remove tubing from the fittings, relieve water pressure, push in on dark gray collar while pulling out on the tubing. See Figure 1 1
5. Connect drain and water supply lines to the freeze resistant fountain. Refer to Figure 1 for component positions. Inline strainer must be used on the inlet water line.
Start-up
1. Turn on building water supply and check all connections for leaks. Repair as required.
2. Stream height is factory set at 35 PSI. If stream height needs to be changed adjust the regulator in the freeze resist ant package. Clockwise adjustment raises stream height, counter clockwise adjustment will lower stream.
3. Adjust operating cable as required. Cable system should have a minimal amount of free play to allow for proper valve operation. If the system is too tight the valve will stay in the on position creating constant water flow . Too much free play will result in non-operation of the valve with the push-buttons.
4. Note: Water from the drain back tube in the freeze resistant package, will continue to run while the valve is actuated.
5. After cable system is adjusted properly stuff flexible insulation into any openings between the outside wall and the interior box.
6. Recheck all connections. If all connections are leak free replace cover(s) on the freeze resistant box(es) and fountain(s).
1/4" O.D. TUBE WATER INLET
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WA TER SUPPLY
BUILDING WATER
INLET
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
FIG . 10
NOTE: WA TER FLOW DIRECTION
SERVICE STOP (NOT FURNISHED)
FIG . 1 1
PAGE 7
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
97565C (Rev. J - 8/07)
EDFP210FP*B EDFP214FP*B EDFP217FP*B
P ARTS LIST
10 11 12 13 14 15 16
17 18
19
20 NS NS
21
1 2 3 4 5 6 7 8 9
P ART NO.ITEM NO.
100322740560
75570C 15009C 27057C 27945C 27946C 40045C
40206000
98118C 45662C 45663C 50198C 51667C 55919C 70425C 28782C
28783C 55000661 55000665
27971C
75672C 72000833
56092C
75520C
56280C
DESCRIPTION
GASKET SCREW-#10 X .50 PINNED TORX NIPPLE ASSY BRACKET-REGULA TOR MOUNTING BRACKET-BASIN BRACKET-BASIN PIVOT HEX NUT 1-5/16 RETAINER BUBBLER ASSEMBLY PUSH BUTTON SLEEVE-PUSH BUTTON GUIDE SNAP BUSHING BUMPER-REG . V AL VE ASSY PUSH BUTTON (EXTENSION) PIVOT ROD FOUNT AIN ARM - SHORT FOUNTAIN ARM - LONG BOTTOM COVER PLA TE - SHORT BOTTOM COVER PLA TE - LONG BACK PANEL ASSY - EDFP217FPC CAP SCREW WASTE ARM ASSY POLY TUBING (CUT TO LENGTH) BIT - PINNED TORX EDGE TRIM
SEE FIG. 13
SEE FIG. 14
21
FIG . 12
8
20
18
2, 17
10
1 1, 19
FIG . 13
16
21
14
13
15
6
7
5
4
12
12
9
FIG . 14
1
97565C (Rev. J - 8/07)
ELKA Y MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
3
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620