Elkay EDFP10FPC Installation Manual

EDFP10/14/17FPC
Installation/Care/Use Manual
EDFP10FPC EDFP14FPC EDFP17FPC
Freeze Resistant Fount ains
Installer T o assure you install this model easily and correctly , PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE INST ALLATION. CHECK YOUR INST ALLA­TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton contains the Freeze Resistant Package LK616A that is installed on an interior heated wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROLYSIS WHICH CAUSES A METALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
FIG. 1
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
96843C (Rev. G - 12/04)
LEGEND:
A = 1/4 DIA. (6mm) HOLE
B = 1/4 DIA. (6mm) SLOT
C = 3/16 DIA. (5mm) HOLE
EDFP10/14/17FPC
EDFP17FPC ROUGH-IN
5. Install the fountain(s) to the wall. Bolt through the fountain and through the back panel into
the wall. (Bolts are not provided). NOTE: The back panel is "sandwiched" between the fountain
and the wall. The back panel DOES NOT support the fountain. All support for the fountain must
come from the mounting wall.
FIG. 3
FINISHED FLOOR
6. Attach drain tube(s) (supplied with freeze-resistant box) to fountain(s) and cut to required
length using the freeze resistant box as a guide.
7. Install freeze-resistant box - see box instructions.
8. Install a service stop (not provided) and make water supply connection from the stop to
the strainer(s) in the freeze-resistant box.
9. Connect fountain water line to freeze-resistant box - see box instructions. Replace bottom
cover(s).
*NOTE: All dimensions are taken from the finished floor on the side of the wall that
the fountain is installed on.
96843C (Rev. G - 12/04)
PAGE 2
1. Wall should already be framed for the fountain using dimensions shown in Fig. 3.
Shown dimensions pertain to installation location. These dimensions are required for
compliance with ANSI Standard A117.1. (and ADA) (Framing shown for reference only).
2. Attach the hanger bracket and panel mounting bracket(s) to the wall as shown in
Fig. 3. Use bolts and flat washers (not provided). Tighten securely.
3. Install the back panel. Place the upper edge of the panel above the hanger on the wall.
Slide the panel down until it engages the hanger. Be sure panel is firmly engaged before
releasing it.
4. Remove bottom cover(s) from fountain(s) and save the screws. Assemble push
rod(s) to fountain(s). See Fig. 6. (Push rods provided with freeze-resistant boxes)
Loading...