Elkay EDFB12FC Specifications

SPECIFICATIONS
GENERAL
#18 gauge, type 304, nickel bearing stainless steel wall drink­ing foun tain designed to meet all sanitary codes. Unit has embossed bubb ler pad and built in stream splitter. Finish is hand blended to a lustrous satin finish.
®
EDFB12FC:Furnished complete with Flexi-Guard bubbler, fully assembled front push bar, flow regulator provides constant stream from 20 to 105 psi water pressure, and domed strainer. No trap furnished. Includes LK109A Glass Filler.
safety
No Lead Drinking Fountain
Fully Recessed Wall Mount
with Glass Filler
Model EDFB12FC
Glass Filler hole is located in back left corner curve of basin
CONSTRUCTION
Exclusive Flexi-Guard
®
Safety Bubbler:Innovative design uti-
lizes a pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Keyed in location to prevent rotation.
Glass Filler: Includes factory installed LK109A cup filler which is installed in the left rear corner. Cup filler projects out at an angle for easier filling.
(483mm)
WALL OPENING
(146mm)
(146mm)
PUSH
PUSH
Model EDFB12FC
ACCESSORIES
MB24: Mounting Box is available as an optional accessory.
STANDARDS
This fountain is certified by WQA to lead-free compliance
including NSF/ANSI 61 and 372.
(13mm)
(17mm)
OPENING
(676mm)
(826mm)
(149mm)
(3mm)
(6mm) SCREWS
(216mm)
(661mm)
(216mm)
(11mm)
(108mm)
(454mm)
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice.
(483mm) WALL OPENING (13mm) (146mm)
(146mm)
OPENING (17mm) (676mm) WALL OPENING (826mm)
OF DRAIN UNPLA (149mm) (3mm) (25mm) RIM HEIGHT (81mm) (788mm)*
(195mm) (6mm) SCREWS (216mm) (216mm) (699mm)*
(775mm)* (11mm)
(11mm)
(661mm)* REQUIREMENT (216mm)
(108mm) (454mm)
Elkay
elkayusa.com
WALL OPENING
UNPLATED COPPER TUBE CONNECT
(25mm)
(81mm)
(788mm)*
RIM HEIGHT
(699mm)
(11mm)
(216mm)
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these featu overlooked.
2222 Camden Court Oak Brook, IL 60523
OF DRAIN
(195mm)
(775mm)
FINISHED FLOOR LINE
res are not
Printed in U.S.A. ©2013 Elkay
SPEC00043 (Rev. 7/13)
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
VICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
No Lead Drinking Fountain Fully Recessed Wall Mount with Glass Filler
Model EDFB12FC
ROUGH-IN DIMENSIONS
(FURNISHED LOOSE)
(17mm)
WALL OPENING
(25mm)
(3mm)
WITH BOLT LOCATIONS
WALL OPENING
(146mm) (146mm)
(119mm)
(119mm)
(119mm)
(119mm)
(483mm)
(25mm)
FOR 1/4" (6mm) DIA. SCREWS
LOCATION
(25mm)
OF FOUNTAIN
(44mm)
(826mm)
FOUNTAIN
(171mm)
(32mm)
INSTALLATION INSTRUCTIONS
1. Remove lower panel from drinking fountain by removing the two screws at the lower corners. Rotate the bottom of the panel out and pull gently down­ward to remove.
2. Water inlet tube to be 3/8" O.D. Waste tailpiece for slip trap is 1-1/4" O.D. Contractor to supply waste trap in accordance with local codes.
3. Connecting lines to be copper and thoroughly flushed to remove all foreign matter before connection to fountain assembly. The furnished strainer should be installed in the supply line.
4. Connect the fountain to supply line with a shut off valve and install a 3/8" (10mm) water line between the valve and fountain. Connect the 3/8 line to the inlet of the strainer by loosening the retaining nut and inserting the tub­ing past the o-rings (approximately 3/4"). Finger tighten nut to lock tubing in place.
5. Stream height is factory set at 35 psi. If supply pressure varies greatly from this, turn adjustment screw on regulator. Clockwise adjustment will raise the stream and counter-clockwise adjustment will lower the stream. For best adjustments, stream should hit the basin 6-1/2" (165mm) from the bubbler.
ACTUATION OF QUICK CONNECT WATER FITTINGS
Fountain is provided with lead free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into the fitting until it reaches a positive stop (approximately 3/4" [19mm]). See Fig. 1.
DIRECTION SER NOTE: WATERFLOW
INLET
TO COOLER COLD WATER SUPPLY BUILDING WATER
WATER INLET 1/4" O.D. TUBE
AB
C TUBE TO ATTACH
IN POSITION SIMPLY PUSH IN
TUBE IS SECURED OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
A B
1/4" O.D. TUBE WATER INLET TO COOLER
NOTE: WATERFLOW
TUBE IS SECURED
IN POSITION
FIG. 1
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
DIRECTION
FIG. 2
PUSH IN COLLET
TO RELEASE TUBE
C
RELEASE TUBE
BUILDING WATER
INLET
SERVICE STOP (NOT FURNISHED)
Elkay
SPEC00043 (Rev. 7/13)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2013 Elkay