SPECIFICATIONS
GENERAL
#18 gauge, type 304, nickel bearing stainless steel wall drinking foun tain designed to meet all sanitary codes. Unit has
embossed bubb ler pad and built in stream splitter. Finish is
hand blended to a lustrous satin finish.
®
EDFB12FC:Furnished complete with Flexi-Guard
bubbler, fully assembled front push bar, flow regulator provides
constant stream from 20 to 105 psi water pressure, and domed
strainer. No trap furnished. Includes LK109A Glass Filler.
safety
No Lead Drinking Fountain
Fully Recessed Wall Mount
with Glass Filler
Model EDFB12FC
Glass Filler hole is located in
back left corner curve of basin
CONSTRUCTION
Exclusive Flexi-Guard
®
Safety Bubbler:Innovative design uti-
lizes a pliable polyester elastomer to prevent accidental mouth
injuries. Flexes on impact, then returns to original position.
Strong. Abrasion-resistant. Anti-sweat. Keyed in location to
prevent rotation.
Glass Filler: Includes factory installed LK109A cup filler which
is installed in the left rear corner. Cup filler projects out at an
angle for easier filling.
(483mm)
WALL OPENING
(146mm)
(146mm)
PUSH
PUSH
Model EDFB12FC
ACCESSORIES
MB24: Mounting Box is available as an optional accessory.
STANDARDS
This fountain is certified by WQA to lead-free compliance
including NSF/ANSI 61 and 372.
(13mm)
(17mm)
OPENING
(676mm)
(826mm)
(149mm)
(3mm)
(6mm) SCREWS
(216mm)
(661mm)
(216mm)
(11mm)
(108mm)
(454mm)
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
(483mm)
WALL OPENING
(13mm)
(146mm)
(146mm)
OPENING
(17mm)
(676mm)
WALL OPENING
(826mm)
OF DRAIN
UNPLA
(149mm)
(3mm)
(25mm)
RIM HEIGHT
(81mm)
(788mm)*
(195mm)
(6mm) SCREWS
(216mm)
(216mm)
(699mm)*
(775mm)*
(11mm)
(11mm)
(661mm)*
REQUIREMENT
(216mm)
(108mm)
(454mm)
Elkay
elkayusa.com
WALL OPENING
UNPLATED COPPER TUBE CONNECT
(25mm)
(81mm)
(788mm)*
RIM HEIGHT
(699mm)
(11mm)
(216mm)
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these featu
overlooked.
2222 Camden Court
Oak Brook, IL 60523
OF DRAIN
(195mm)
(775mm)
FINISHED FLOOR LINE
res are not
Printed in U.S.A.
©2013 Elkay
SPEC00043 (Rev. 7/13)
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
VICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
No Lead Drinking Fountain
Fully Recessed Wall Mount
with Glass Filler
Model EDFB12FC
ROUGH-IN DIMENSIONS
(FURNISHED LOOSE)
(17mm)
WALL OPENING
(25mm)
(3mm)
WITH BOLT LOCATIONS
WALL OPENING
(146mm) (146mm)
(119mm)
(119mm)
(119mm)
(119mm)
(483mm)
(25mm)
FOR 1/4" (6mm) DIA. SCREWS
LOCATION
(25mm)
OF FOUNTAIN
(44mm)
(826mm)
FOUNTAIN
(171mm)
(32mm)
INSTALLATION INSTRUCTIONS
1. Remove lower panel from drinking fountain by removing the two screws at
the lower corners. Rotate the bottom of the panel out and pull gently downward to remove.
2. Water inlet tube to be 3/8" O.D. Waste tailpiece for slip trap is 1-1/4" O.D.
Contractor to supply waste trap in accordance with local codes.
3. Connecting lines to be copper and thoroughly flushed to remove all foreign
matter before connection to fountain assembly. The furnished strainer
should be installed in the supply line.
4. Connect the fountain to supply line with a shut off valve and install a 3/8"
(10mm) water line between the valve and fountain. Connect the 3/8 line to
the inlet of the strainer by loosening the retaining nut and inserting the tubing past the o-rings (approximately 3/4"). Finger tighten nut to lock tubing
in place.
5. Stream height is factory set at 35 psi. If supply pressure varies greatly from
this, turn adjustment screw on regulator. Clockwise adjustment will raise
the stream and counter-clockwise adjustment will lower the stream. For
best adjustments, stream should hit the basin 6-1/2" (165mm) from the
bubbler.
ACTUATION OF QUICK CONNECT WATER FITTINGS
Fountain is provided with lead free connectors which utilize an o-ring water
seal. To remove tubing from the fitting, relieve water pressure, push in on gray
collar while pulling on the tubing. To insert tubing, push tube straight into the
fitting until it reaches a positive stop (approximately 3/4" [19mm]). See Fig. 1.
DIRECTION
SER
NOTE: WATERFLOW
INLET
TO COOLER
COLD WATER SUPPLY
BUILDING WATER
WATER INLET
1/4" O.D. TUBE
AB
C
TUBE TO ATTACH
IN POSITION
SIMPLY PUSH IN
TUBE IS SECURED
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
A B
1/4" O.D. TUBE
WATER INLET
TO COOLER
NOTE: WATERFLOW
TUBE IS SECURED
IN POSITION
FIG. 1
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
DIRECTION
FIG. 2
PUSH IN COLLET
TO RELEASE TUBE
C
RELEASE TUBE
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
Elkay
SPEC00043 (Rev. 7/13)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2013 Elkay