Elkay EDF210C, EDF310C User Manual

Page 1
EDF210C / EDF310C FOUNT AIN
INSTALLATION, CARE & USE MANUAL
EDF210C & EDF310C Series Fountains
EDF210C TWO ST A TION FOUNTAIN
EDF310C THREE ST A TION FOUNTAIN
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO W ATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A W A Y FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREATING AN ELECTROL YSIS WHICH CAUSES A METALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
INSTALLATION INSTRUCTIONS
1. Familiarize yourself with the components of the drinking fountain.
2. Determine location of rough-in and plumbing connections. Mount hanger bracket(s) to wall at desired height.
3. Install fountain to wall. Install additional fasteners to bolt fountain securely to wall.
5. Turn on water supply and check for leaks at all plumbing and drain connections. Fix all leaks as required.
PAGE 1
98129C (3/05)
Page 2
EDF210C / EDF310C FOUNT AIN
ROUGH - IN DIMENSIONS
EDF210C (TWO STATION)
FIG . 1
ROUGH - IN DIMENSIONS
EDF310C (THREE STATION)
FIG . 2
98129C (3/05)
PAGE 2
Page 3
ITEMIZED PARTS LIST
ITEM NO. PART NO. DESCRIPTION
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
56073C 40169C 40048C 40089C 40322C 56011C 55997C 61313C 75580C 45336C 50074C 28568C 55996C 56092C 70682C 45852C 45853C 45854C 15005C 28580C 50986C 45855C
Bubbler Assy. Hex Nut Button Cover Orifice Assy. Bubbler Housing Pedestal Regulator Locking Nut Strainer/Ferrule Assy. Gasket - Tailpipe Fountain Strainer Polytubing Tee - 1/4 Trap Assy. Wasteline Tee Assy. Tailpipe Regulator Retaining Nut Hanger Bracket Regulator Holder Wasteline
EDF210C / EDF310C FOUNT AIN
FIG . 3
1 - SEE FIG. 3
12
6
1
5
7
9
14
14
13
15
14
2, 3, 4,
8, 19, 21
10, 1 1
18 17
14
16
FIG . 4
20
10, 1 1
22
1/4" O.D. TUBE WATER INLET TO COOLER
FIG . 5
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPL Y
NOTE: WA TER FLOW
DIRECTION
BUILDING WA TER INLET
SERVICE STOP (NOT FURNISHED)
FIG . 6
PAGE 3
98129C (3/05)
Page 4
EDF210C / EDF310C FOUNT AIN
ITEMIZED PARTS LIST
ITEM NO. PART NO. DESCRIPTION
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
56073C 40169C 40048C 40089C 40322C 56011C 55997C 61313C 75580C 45336C 50074C 28569C 55996C 56092C 70682C 45852C 45853C 45854C 15005C 28580C 50986C 45857C 45858C 45856C
Bubbler Assy. Hex Nut Button Cover Orifice Assy. Bubbler Housing Pedestal Regulator Locking Nut Strainer/Ferrule Assy. Gasket - Tailpipe Fountain Strainer Polytubing Tee - 1/4 Trap Assy. Wasteline Tee Assy. (Vertical) Tailpipe Regulator Retaining Nut Hanger Bracket Regulator Holder Wasteline (J-Tube) Wasteline (Straight) Wasteline Tee Assy. (Horizontal)
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water
flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire. CAUTION: DO NOT FILE OR CUT ORIFICE
MATERIAL. Actuation of Quick Connect Water Fittings: Cooler is
provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (see figure 6).
Bubbler Replacement: When installing replacement bubbler and pedestal, tighten nut (Item 9, figure 3) only to hold parts snug in position. Do not overtighten.
1 - SEE FIG. 3
FIG . 7
2, 3, 4,
8, 19, 21
12
18
17
16
20
10, 1 1
23
14
18
24
10, 1 1
14
2, 3, 4, 8
20
10, 1 1
22
14
PRINTED IN U.S.A.
98129C (3/05)
14
17
14
ELKAY MANUFACTURING COMP AN Y • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
PAGE 4
15
14
14
13
Loading...