Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA­TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
INSTALLATION INSTRUCTIONS
1. Wall should already be framed for the fountain using the positioning dimensions shown in Figure 1. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight).
2. Install rough-in plumbing as shown in Figure 1. Connecting lines to be unplated copper. Run supply water inlet line and connect to a service stop (not provided). Turn on supply water and flush thoroughly. Close water supply.
3. Secure the fountain to the wall using bolts and washers (not provided). Tighten securely.
4. Make water supply connections from service stop to the fountain. Turn on water supply and check for leaks. Newly installed
water supply line should be insulated after leak check is completed.
5. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
6. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove items 7 and 8 (See Figure 3) and adjust the screw on the regulator (Item 5). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream should be approximately 1" (25mm) above the bubbler guard. (See Figure 2).
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from orifice with a small round file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials.
96540C (Rev. G - 3/01)
EDF20C
**
* SUGGESTED MOUNTING HEIGHTS*
26" (660mm) FOR SMALL CHILDREN 34" (864mm) FOR CHILDREN OR ADULTS 40" (1016mm) FOR ADULTS
LEGEND A = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
B = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT
FIG. 1
10 11 12 13
C = USE OUTER HOLES TOP AND BOTTOM FOR CABINET MOUNTING
FINISHED FLOOR LINE
PARTS LIST
PART NO.ITEM NO.
1 2 3 4 5 6 7 8 9
45703C 60291C 45675C 40322C 61313C 10031C 40048C 40089C 26758C 21812C 26759C 70059C 75580C
Bubbler Assy Screen Bubbler Body Orifice Assy Regulator Retaining Nut Button Cover Nut Cabinet Basin and Tailpipe Assy Bottom Cover Speed Nut Lock Nut
DESCRIPTION
7
8
54
6
1
3
FIG. 2
PRINTED IN U.S.A
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523  630.574.8484
96540C (Rev. G - 3/01)
2
13
FIG. 3
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 2
Loading...