Elkay ECU8-1G Installation Manual

ECU8*1G ECU8*2G ECU8*3G
Refrigeration Package
INSTALLATION, CARE & USE MANUAL
INSTALLATION
1. Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is
within 1/2” (13 mm) of louver panel when panel is in place.
2. Water inlet is 3/8” (10 mm) O.D. unplated tube connector. Contractor to supply connections as required.
3. Connecting lines to be made of unplated copper. Thoroughly ush all lines to remove all foreign matter
before connecting to cooler.
4. Connect cooler to building supply with a shut-off valve and install a 3/8” (10 mm) water line between the valve and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches a positive stop, approximately 3/4” (19 mm).
Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specied on cooler serial
plate. Never wire the compressor directly to the power supply.
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal con-
tent of the water. This condition is avoidable by using the proper materials indicated below. Drain ttings which are
provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady
stream ow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water, adjust screw
on item no. 5.
Ventilation: Cabinet louvers and condenser ns should be periodically cleaned with a brush, air hose, or vacuum
cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring
seal. To remove tubing from the ttings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into tting until it reaches a positive stop, approximately 3/4”.
OVERLOAD
COMPRESSOR
RELAY
WIRING DIAGRAM
3
2
C
S M
56
23
FAN
COLD CONTROL
(WATER)
BLACK
WHITE GROUND
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
Page 1
0000000969 (Rev. B - 01/15)
ECU8*1G ECU8*2G ECU8*3G
ITEM NO.
1 2 3 4 5
*6
7 8
9 10 11 12
PART NO.
0000000886
98775C 98778C 70841C 98773C 36322C
0000000238
98777C 20282C 66703C 98776C 36208C
PARTS LIST
DESCRIPTION
KIT - EVAPORATOR REPLACE ASSY KIT - FAN MTR/BLADE/NUT KIT - HEATX/DRIER UNION - BULKHEAD KIT - COLD CONTROL/SCREWS COMPRESSOR SERV. PAK KIT- ELECT/RELAY/COVER/OL KIT- COMPRESSOR MTG HDWE BRACKET - FAN MTG DRIER KIT - CONDENSER/DRIER POWER CORD
3
9
1
10
220V 50/60HZ PARTS LIST
ITEM NO.
2
*6
7
12
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE
WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF REPLACEMENT PART.
PART NO.
0000000244 0000000245 1000002147
36092C 98751C 98752C 31506C
KIT - FAN MTR/BLADE/NUT/SHROUD (50 HZ) KIT - FAN MTR/BLADE/NUT/W/O SHRD (60 HZ)
COMP SERV. PAK (50 HZ) COMP. SERV. PAK (60 HZ) KIT-ELECT/RELAY/CVR/OL(50 HZ) KIT-ELECT/RELAY/CVR/OL(60 HZ) POWER CORD (50/60 HZ)
DESCRIPTION
4
8
2
11
6
7
12
5
ELKAY MANUFACTURING COMPANY•2222 CAMDEN COURT•OAK BROOK, IL 60523•630.574.8484
0000000969 (Rev. B - 01/15
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
PAGE 2
Loading...