Elkay DRKR14RC Installation Manual

DRKR14RC, DRKRV14RC
:
INSTALLATION, CARE & USE MANUAL
Countertop Fountains
INSTALLER
!
CAUTION
!
WARNING
!
WARNING
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however , cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water .
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building’s plumbing circuits.
Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only .
Page 1
97930C (Rev. C - 4/05)
Figure 1
DRKR14RC, DRKRV14RC
1. Make 13-1/4” (337mm) diameter cutout in desired location on countertop. Maintain the 7-5/8” (194mm) dimension from the front edge for ADA compliance. (See Figure 1)
2. Install bubbler assembly to fountain. Align recess in underside of bubbler with dimple in fountain.
3. Apply caulk (not provided) around cutout and waste opening.
4. Place fountain over opening and drop in strainer. (See Figure 2)
5. From underside, position and secure tiedown bracket using waste fitting. (See Figure 3)
6. Use screws with nuts and washers (provided) to tighten unit to countertop. Wipe off excess caulking. (See Figure 3)
7. Determine required length of waste line and cut to appropriate length. 1-1/4” O.D. waste tube furnished. 1-1/4” slip trap, waste elbow and extension not provided.
8. Make water supply connections from service stop to the 3/8” O.D. unplated copper tube coming out of the strainer. Turn on water supply and check for leaks. Newly installed water supply line should be insulated after leak check is completed.
CAUTION: DO NOT SOLDER tubes into the strainer as damage to the o-rings may result.
Figure 2
Figure 3
9. These products are designed to operate on 20-105 PSIG supply line pressure. If the supply pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
10. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply pressure varies greatly from this, adjust the screw on regulator item 16 by using
a small screwdriver through the small hole in the push button item 14 (See Fig.7). Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment stream should hit basin approximately 6-1/2” from bubbler.
5
8
1
2, 3, 4
BUBBLER DETAIL VANDAL RESIST ANT
6
9
Basin
10
7
BUBBLER DETAIL
NOTE:
When installing replacement bubbler and pedestal, tighten nut (Item 7) only to hold parts snug in position. Do Not Overtighten.
Figure 4 - Bubbler Details
97930C (Rev. C - 4/05)