Siren & Stainless Steel Enclosure
ELK-150RT
The ELK-150RT is a self-contained Siren in a
tampered “No Rust” stainless steel enclosure. It
features two sealed reed tamper switches, one on
the Back plate and one on the Front Cover. The
switches are normally closed and pre-wired in
series. The ELK-150RT can produce two distinct
sounds from a single input trigger. The stainless
steel exterior reflects the color of the mounting
surface allowing the ELK-150RT to blend easily
with any residential or commercial building.
Also available is the ELK-45 which is the self
contained siren without the stainless enclosure; the
ELK-SL1 Strobe Light which can be added to the
enclosure, and the ELK-1RT which is a 30 watt
speaker in the stainless enclosure.
The ComboTrigger™ option allows controls which
have a single alarm output and pulsing option to
activate both the burglar and fire alarm sounds.
ELK-150RT
with optional
ELK-SL1C
Clear Strobe
Features
• Installer Friendly - Easy to Mount.
• Sealed Reed Tamper Switches at single bolt
closure and at rear of cabinet.
• No Rust - No Mess - Exterior / Interior use.
• Compact - Less Noticeable.
• Loud - Rivals Sound of Larger Speakers.
• Heavy Duty 1.8 lb Magnet.
• ComboTrigger™ For Single Outputs.
• Stainless Mounting Hardware Included.
• Lifetime Limited Warranty.
Specifications
• Operating Voltage: 6 to 14 Volts D.C.
• Current Draw: 1.2 Amps
• Sound Level: 118 dB @ 1 meter, 14 Volts DC.
• Enclosure: #304 Stainless Steel.
• Size: 5"H x 5"W x 4"D.
Features and Specifications subject to change without notice.
Tamper-Proof Cover Self-Contained
Back Plate w/
(2) Tamper
Switches
Siren & Speaker
Hardware Pak
Cut-away
view
Components of
ELK-150 RT
PO Box 100 • Hildebran, NC 28637 • 800-797-9355 • 828-397-4200
Fax 828-397-4415 • www.elkproducts.com • info@elkproducts.com
08/2010
ELK
PRODUCTS, INC.
Instructions
ELK-150RT
Install top edge of backplate at least 1"
below any soffit or building overhang.
Wall Mounting Holes
Electrical Box
Mounting Holes
Wire /
Conduit
Entry
Figure 1
TAMPER LEADS
ELK-901G
White
ELK-901G
White
POWER to SIREN
ELK-901G
Black
Red
ELK-901G
ELK-901G
INSTALLATION OF THE ELK-150RT SIREN
The ELK-150 RT is a self-contained siren in a tampered "No Rust" stainless steel
enclosure. It incorporates two sealed reed tamper switches for enhanced
reliability and ease of use.
1. Using the backplate as a template, mark and drill the 4 mounting holes and
the wire or conduit entry hole (see Figure 1). Insert the (4) 1/4 x 1” wall
anchors, then partially install the top two #10 x 1” screws.
2. Route the wire or conduit through the hole provided and hang backplate on
the top screws. Then install remaining two screws and & tighten all four.
3. Temporarily hang the Siren/speaker on the backplate by aligning the slotted
insert on the top edge of the Siren with the 1/2" recessed tab on the bottom
edge of the backplate. Press Siren onto tab. (See Figure 2)
4. Connect the two white wires from the tamper switches to a 24 hour closed
loop on the control panel (the switches are already connected in series).
5. Connect the Red (+) and Black (-) wires from the Siren to the control's alarm
output. The Siren produces a Yelp sound from a constant voltage input. If the
voltage input is pulsed the siren produces a low pitch rise. This
ComboTrigger
has only a single alarm output with a pulse option. Recommended wire
gauge from control is 18 AWG.
NEG (-) Black = Negative (-) terminal from Control's Alarm output.
YELP (+) RED = Positive (+) terminal from Control's Alarm output
TM
feature allows two sounds to be activated by a control that
Tuck wires into
lower corner of
backplate away
from top inside
corners.
Figure 2
Figure 3
6. Move the Siren/speaker from its hanging position to its final mount by aligning
it's top and bottom slots with the 1/2" tabs on the top edge of the backplate
and in the bottom center above the bolt threads. (See Figure 3) Press firmly.
7. Slide front cover over speaker. Lift up to engage the tabs in the cover with the
two "U" shaped slots on the top edges of the backplate. (Figure 4) Lower
cover until tabs are in slots. Push cover towards wall, then lift up to lock tabs
in slots. Thread 1/4-20 hex bolt into hole on bottom of cover and tighten until
secure.
8. The front cover tamper switch is pressed closed by the front cover during the
final 3 to 4 full turns of the hex bolt. If possible, test the operation of the
tamper switch using a continuity meter.
Note: The ELK-150RT is designed for Single Output Alarm Controls that use
a STEADY Output for BURG or a PULSING Output for FIRE. For an Alarm
Control panel that has separate BURG and FIRE alarm outputs connect the
Red wire to each output, then program one output for Steady(Burg) and the
other for Pulsing(Fire). Connect the Black wire to Neg.
Slide over speaker.
Lower tabs into
slots.
Push towards wall.
Figure 4
Lift up to lock, then
secure with hex bolt.
Tamper switch is
closed by the front
cover during the final 3
to 4 turns of the hex
bolt.