Eliwell IC 901 User Manual

THE USER INTERFACE
The user has a display and four keys for controlling status and programming of the instrument.
KEYS AND MENUS
UP key Scrolls through the menu items
Increases the values
DOWN key Scrolls through the menu items
FNC key ESC function (exit)
SET key Accesses the setpoint
Accesses the menus Confirms the commands
The instrument has two main menus: the “Machine Status” and “Programming” menu.
ACCESSING AND USING MENUS
The instrument is programmed by menus. To access a menu, press and quickly release the “SET” key (“Machine status” menu) or press the “SET” key for over 5 seconds (“Programming” menu). To access the contents of each folder, indi­cated by the relevant label, just press the “SET” key once. You can now scroll through the contents of each folder, modify it or use its func­tions. If you do not use the keyboard for over 15 seconds (time-out) or if you pres­ence the “FNC” key once, the last value shown on the display is confirmed and you return to the previous screen mask.
MACHINE STATUS MENU
To access the “Machine Status “menu, press and quickly release the “SET” key. The “Set” folder label appears. To view the Setpoint value, press the “SET” key again. The Setpoint value appears on the display. To change the Setpoint value, use the “UP” and “DOWN” keys within 15 seconds. If the parameter is LOC = y the Setpoint cannot be changed.
PROGRAMMING MENU
To enter the “Programming” menu, press the “SET” key for more than 5 seconds. If specified, the access PASSWORD will be requested, (parameter “PA1”), and the label of the first folder will follow. To scroll through the other folders, use the “UP” and “DOWN” keys. To enter the folder, press “SET”. The label of the first visible parameter appears. To scroll through the other parameters, use the “UP” and “DOWN” keys. To change the parameter, press and release “SET” then set the desired value with the “UP” and “DOWN” keys, and confirm with the “SET” key, to move to the next parameter.
COPY CARD
The Copy Card is an accessory that con­nected to the serial door TTL permits both fast programming of instrument’s parame­ters (download), and the possibility to save the instrument’s parameters (upload) in order to use them to ri-program other equivalent instruments. To do this opera­tion enter the folder identified from label “FPr” and use parameters “UL” or “dL” depending on the case; to start uploading (downloading) simply press “SET” button.
KEYBOARD LOCKING
The instrument includes a facility for dis­abling the keyboard, by programming the “Loc” parameter (see folder with “Dis” label). If the keyboard is locked, you can still access the programming menu by pressing the “SET” key. The Setpoint can also be viewed.
DIAGNOSTICS
The alarm condition is always signalled by the buzzer (if present) and by the led of the alarm icon The alarm signal produced by a faulty room probe (probe 1) is shown as E1 on the instrument display 1.
INSTALLATION
The instrument is designed for flush panel mounting. Insert the unit through a 71x29 mm panel cut-out and affix with the U-bracket supplied. Select a location which will not be subject to high humidity or condensation and allow some ventilation to provide cooling to the instrument.
ELECTRICAL CONNECTIONS
Attention! Never work on electrical con­nections when the machine is switched on. The instrument is equipped with screw ter­minal boards for connection of electrical
cables with a diameter of 2.5 mm
2
(one conductor only per terminal for power connections). For the capacity of the ter­minals, see the label on the instrument. Relay outputs are voltage free. Do not exceed the maximum permissible current – in case of higher loads, use a contactor of adequate power. Make sure that the supplied voltage matches the values speci­fied for the instrument. In the versions supplied on 12V, the power supply must be provided via a safety trans­former protected by a 250 mA delayed fuse. The probes do not have any insertion polarity and can be lengthened by using a normal bipolar cable (note that if the probes are lengthened, this will affect the behaviour of the instrument in terms of EMC electro-magnetic compatibility – wiring must be done with great care). We advise you to keep the probe and sup­ply cables well away from the power cables.
CONDITIONS OF USE
PERMITTED USE
For safety reasons the instrument must be installed and used according to the instruction provided and in particular, under normal conditions, parts bearing dangerous voltage levels must not be accessible. The device must be adequately protected from water and dust as per the application and must also only be accessible via the use of tools (with the exception of the frontlet). The device is ideally suited for use on household appliances and/or similar refrig­eration equipment and has been tested with regard to the aspects concerning European reference standards on safety.
IC 901
electronic thermostat with single output
fnc
set
LED
Position Associated function Status
Relay 1 ON for relay ON, flashing for delay, disabled protection
or activation
Alarm ON for an active alarm
It is classified as follows: o according to its manufacture: as an automatic electronic control device to be incorporated by independent mounting; o according to its automatic operating fea­tures: as a 1 B-type operated control type; o as a Class A device in relation to the cat­egory and structure of the software.
USE NOT PERMITTED
Any other use other than that permitted is de facto prohibited. It should be noted that the relay contacts provided are of a practical type and therefore subject to fault. Any protection devices required by product standards or dictated by common sense due to obvious safety reasons should be applied externally.
LIABILITY AND RESIDUAL RISKS
Invensys Controls Italy S.r.L. shall not be liable for any damages deriving from:
- installation/use other than that pre­scribed and, in particular, that which does not comply with safety standards anticipat­ed by regulations and/or those given here­in;
- use on boards which do not guarantee adequate protection against electric shock, water or dust under the conditions of assembly applied;
- use on boards which allow access to dan­gerous parts without the use of tools;
- tampering with and/or alteration of the products;
- installation/use on boards not complying with the standards and provisions of cur­rent legislation.
DISCLAIMER
This publication is the exclusive property of Invensys Controls Italy S.r.L. who absolutely prohibits its reproduction and distribution unless expressly authorised by Invensys Controls Italy S.r.L. Although great care has been taken with regard to the preparation of this docu­ment, Invensys Controls Italy S.r.L. does not assume any responsibility whatsoever in relation to its use.
The same applies to every individual and company involved in creating and drawing up this manual. Invensys Controls Italy S.r.L. reserves the right to make any amendment, esthetical or functional, with­out giving prior notice and at any time.
TECHNICAL DATA
Frontal panel protection: IP65. Container: plastic body in resin type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in thermoplastic resin. Dimensions: frontal panel 74x32 mm, depth 60 mm. Installation: on panel, with template 71x29 mm (+0.2/–0.1 mm). Ambient temperature: –5…55 °C. Storage temperature –30…85 °C. Operating environment humidity: 10…90% RH (non condening). Storage environment humidity: 10…90% RH (non condensing). Viewing range: –50…99 °C on 2 digit + mark display. Analog inputs: one PTC or NTC input (selectable through parameter). Digital outputs: one relay output, SPDT 8(3)A 250Va relay or SPDT 15A(1hp)
250Va relay (for capacity relay see label on the instrument).
Measuring range: from –50 to 99 °C. Precision: 0.5% better than full scale. Resolution: 1 °C. Consumption: according to model. Power supply: according to model. See label on instrument.
ID 901 2/2
Invensys Controls Italy s.r.l
via dell'Industria, 15 Zona Industriale Paludi 32010 Pieve d'Alpago (BL) ITALY Telephone +39 0437 986111 Facsimile +39 0437 989066 Internet http:/www.climate-eu.invensys.com
1/2002 ing cod. 9IS22048