E-Lite 600N, 2200N-B, 2200N-A, 12KN-A, 12KN-B Installation & Adjustment Instructions

...
For Power Supply Models:
600N, 2200N-A, 2200N-B, 12KN-A, 12KN-B, 12KN -C, 12KN-D
POWER SUPPLY
INSTALLATION & ADJUSTMENT
INSTRUCTIONS
Use Exclusively with FLATLITE® Electroluminescent
Lamps.
! IMPORTANT SAFEGUARDS !
should always be followed including the following:
• This product must be installed and serviced by electrical contractors familiar with the instructions in this manual and local building codes.
• FLATLITE® Lamp is an electrical appliance operating at up to 280Vac.
• Do not cut or pierce without proper tools and training.
• Never power the unit from a dimmable AC source.
• Never for use in or under water.
• Never install in an accessible area without a protective cover to prevent access.
• Do not install against an ungrounded metal surface.
• Always install in accordance with all applicable electrical codes.
• Always disconnect power from the FLATLITE® system before servicing.
• Equipment must be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel.
• Use of any components not supplied with the FLATLITE® system or the modification of the components supplied may cause an unsafe condition.
• Do not use this equipment for other than its intended purpose
• This equipment is approved and rated for connection of lamps as specified in the system design section. Never exceed the Total or Minimum Load Rating of any power supply.
SAVE THESE INSTRUCTIONS
MAKING ADJUSTMENTS
Tools Needed:
Phillips head screw driver
Nonconductive blade adjustment tool
Voltmeter capable of reading up to 400VAC RMS
Installed Lamp size (in square inches)
Needle-nose pliers
1. Completely disconnect Power Supply from any power source
2. If any of the optional CMD modules will be used, leave it
disconnected until the Power Supply has been fully adjusted. 3a.
Models 600N, 2200N-A, B: Remove the cover from the Power Supply and place the supply base so that the components inside are accessible and the choke(s) are to the right.
3b.
Models 12KN-A,B,C and D: Remove the access port cover from the top of the Power Supply and place the supply so that the opening is toward you and to the right.
4. Confirm that the input voltage select jumper is placed correctly for your operating voltage 120 or 240VAC (See Figure 1, 2 or 3 for jumper location). Refer to the marking on the Printed Circuit Board (PCB). The jumper tab should connect the front two pins for 240VAC and the back two pins for 120VAC. (Disregard this step for Models 12KN-A,B,C,D - voltage adjusts automatically).
5. Next, match the Power Supply to the lamp size by connecting the chokes appropriately (see specifics in Figure 1, 2, or 3. Note: 2200N-B requires no choke setup, and chokes on 12KN models are factory set).
6. Locate the output “VOLTAGE ADJ” (white pot) and limit­adjust “VOLTAGE LIMITING” (blue pot) potentiometers. See Figure 1, 2 or 3 for locations. When adjusting these pots use a NON CONDUCTIVE TOOL.
7. The blue limit pot is preset at the factory and is locked with glue. Set up instructions for this blue limit pot are included in case the glue has been removed or specific instructions to adjust the pot are given from the factory. Turn the white pot all the way counter clockwise and the blue limit pot all the way clockwise.
E-Lite Technologies, Inc. Power Supply Instruction Manual - Page 1 of 4
8. Connect the voltmeter to the output of the Power Supply. This can be done by inserting the probes into the back if the lamp Molex connector or attaching it to the connection
points of the distribution wire (12KN models), prior to connection points being insulated.
NOTE: All adjustments must be made with the lamp connected to the Power Supply. The Power Supply must be adjusted to TOTAL area of all lamp being connected to an individual Power Supply. If connecting multiple lamps, all lamps must be wired in parallel.
9. Turn on the Power Supply, the lamp should be dimly lit,
the green “Power On” LED will be lit and the voltage should read less then 280VAC.
CAUTION: USE EXTREME CARE WHEN MAKING
ADJUSTMENTS WITH POWER ON AND COVER OFF.
10. Adjust the voltage output and voltage limit as follow:
Turn the white pot all the way clockwise, watching
the voltmeter. The output should stay below 320VAC. If it does not, discontinue setup and check that the Power Supply is properly sized to the lamp.
Turn the blue pot counterclockwise until the meter
reads 330VAC.
Turn the white output counterclockwise to the
desired voltage setting, not to exceed 280VAC.
Allow system to stabilize for five minutes and reset
the white pot to the desired voltage or the 280VAC limit. NOTE:
At 280VAC the lamp is operating at its brightest setting. To reduce brightness, adjusting the output lower (counter­clockwise) until brilliance matches your requirements will increase the life of the lamp and provide for further level of compensation.
Turn off power and replace the cover or port access
cover.
11. At this point any CMD module can be attached and set as desired.
12. All Models 600N, 2200N-A, B, and 12KN-A,B,C,D have ground fault protection capability. To test this, press the red button and the lamp will turn off. To restart the power supply, switch the unit OFF and the ON again.
TROUBLESHOOTING
PROBLEM: LAMP DOES NOT LIGHT
1. Check that Power Supply is plugged into working outlet.
2. Check that Power Supply switch is “ON”.
3. Check the fuses.
4. Check output - check that Power Supply has been properly adjusted for the lamp load (see Adjustment instructions, page 2).
5. If 2200N-A or B, check that the terminals mounted on E-16 and E-17 are not touching each other or any other components on the Printed Circuit Board.
6. Check that the Lamp connection(s) to the Power Supply is (are) well made.
7. Check that the Lamp is wired correctly:
1. Turn off the power supply
2. Unplug the Lamp from the Power Supply
3. Measure across the leads with a digital multimeter to check: a. Continuity-if continuity, there is a short in the wiring b. Capacitance-If no capacitance, there is an open circuit in the wiring
The problem with wiring may be in the lamp crimp attachment or in the distribution wiring. Disconnect lamp from distribution wiring to troubleshoot.
PROBLEM: LAMP BLINKS OR FLASHES
1. Check that the Power Supply has been set to the proper input voltage.
2. Check that the power supply has been adjusted for the correct lamp load.
PROBLEM: LAMP IS DIM
1. Check that the Power Supply has been properly adjusted for the lamp load (see Adjustment instructions, page 2).
2. If 2200N-A or B, check that the terminals mounted on E-16 and E-17 are not touching each other or any other components on the Printed Circuit Board.
3. Check if the Lamp has been operating past it’s useful life.
4. Call E-Lite for Technical Assistance.
PROBLEM: POWER SUPPLY ADJUSTMENTS OPERATE REVERSE FROM
NORMAL
1. Check that the Lamp is within the range of the Power Supply as set.
2. Replace Power Supply with properly sized model.
PROBLEM: THE 280VAC OPERATING VOLTAGE CANNOT BE REACHED
1. Check that the Power Supply has been set to the proper input voltage (does not apply to 12KN-A, B, C, or D).
2. Check that the Lamp is within the range of the Power Supply as set.
3. Check that the Lamp connection(s) to the Power Supply is (are) well made.
4. If 2200N-A or B, check that the terminals mounted on E-16 and E-17 are not touching each other or any other components on the Printed Circuit Board.
5. Replace Power Supply with properly sized model.
PROBLEM: POWER SUPPLY OPERATED INTERMITTENTLY
1. Check that the Power Supply is not overheated. Relocate the Power Supply to a cooler area or provide ventilation.
NOTE: The Power Supply has a Thermal Protection Circuit that protects the
components when the internal temperature exceeds a preset level.
E-Lite Technologies, Inc. Power Supply Instruction Manual - Page 2 of 4