eLine Technology UB12900 User Manual

Specification
eLine Technology
eLineTechnology.com
1
Sealed Lead-Acid Battery
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. r ecognized under file number MH 20567.
UPG No. 45826
UB12900
Maintenance-Free
Nominal Voltage Nominal Capacity
20-hr. (4.50A) 10-hr. (8.37A) 5-hr. (15.30A) 1-hr. (54.00A)
Approximate Weight Internal Resistance (approx.) Shelf Life (% of normal capacity at 77º F (25º C))
3 Months 6 Months 12 Months 91% 82% 64%
Temperature Dependancy of Capacity
104º F 77º F
32º F 5º F
102% 100% 85%
Physical Dimensions: in (mm)
306 (12.05)
L: 12.05in (306.1 mm) W: 6.61in (167.9 mm)
210 (8.27)
168 (6.61)
H: 8.27in (210.1 mm) TH: 9.13in (231.9 mm)
12 volts 77º F (25º C) 90 Ah
83.7 Ah
76.5 Ah 54 Ah
59.5 lbs (27 kgs) 7 mΩ
(20 hour rate)
65%
Charge Method Cycle Use
Initial Current Control Voltage
Float Use
Control Voltage
Terminals
(Constant Voltage)
(Repeating Use)
27 A or smaller
14.5-14.9 V
13.6-13.8 V
Constant Current Discharge Characteristics Unit:A (25°C, 77°F)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR F.V/Time
309.3 225.7 158.8 96.1 50.2 29.3 21.5 16.7 13.8 9.7 8.8 4.7 9.60V
272.5 205.7 142.1 91.1 47.2 27.9 20.9 16.3 13.5 9.5 8.5 4.6 10.20V
262.5 195.6 133.8 88.6 46.0 27.3 20.4 16.1 13.4 9.4 8.4 4.6 10.50V
252.5 185.6 125.4 86.1 44.3 26.6 19.9 15.8 13.0 9.2 8.4 4.5 10.80V
242.4 175.6 117.0 83.6 42.6 25.9 19.2 15.3 12.7 8.9 7.9 4.3 11.10V
Constant Power Discharge Characteristics Unit:W (25°C, 77°F)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR F.V/Time
3284.6 2480.4 1687.0 1020.8 581.0 338.6 249.1 194.0 159.7 112.9 102.0 54.9 9.60V
3025.5 2283.1 1577.5 1011.6 545.9 323.5 242.4 188.9 125.5 110.4 99.5 53.5 10.20V
2977.0 2218.7 1516.5 1004.9 528.4 316.0 236.6 185.6 154.7 109.5 97.8 52.8 10.50V
2938.5 2160.2 1459.7 1002.4 514.1 309.3 231.6 182.2 152.2 107.0 97.0 52.6 10.80V
2885.0 2089.2 1392.8 994.8 507.5 308.5 229.1 181.4 151.3 106.2 94.5 51.0 11.10V
F1206-1
Discharge Time vs. Discharge Current
eLine Technology
eLineTechnology.com
2
Discharge Characteristics
UPG No. 45826
UB12900
Maintenance-Free
Cycle Life vs Depth of Discharge Shelf Life & Storage
Charge Current & Final Discharge Voltage
Application
Cycle Use Standby
Temperature Set Point Allowable Range
25 25
Charge Voltage(V/Cell)
(77 ) (77 )
2.45 2.40~2.50
2.325 2.30~2.35
Max.Charge Current
0.30C
Final Discharge
Voltage V/Cell
Discharge Current(A)
Effect of Temperature on Capacity Open Circuit Voltage vs Residual Capacity
1.75 1.70 1.60 1.30
0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C
Let UPG Power Your Life.