LED Cloud
SPECIFICATIONS:
Model: LED Cloud
Supply Voltage: 100V ~ 240V 60Hz/50Hz
LEDs: 5 x 3W LEDs
Power Consumption: 27.5W
Weight: 4.4lbs./ 2kgs.
Size: 9.8” (L) x 7” (W) x 9.5” (H)
Fuse: 3 Amp
Working Position: Any Safe position
Duty Cycle: None
DMX Channels: 4
Colors: RGBWA
Warranty: 1 Year
CAUTION! Please read and under-
stand these instructions before
installing or operating this unit.
Operating Instructions:
This unit is a 4 channel DMX intelligent LED unit. It can be run as a stand-alone or in a master-slave
configuration. The unit has 3 operating modes; sound active mode, auto mode or DMX controlled.
This unit has been tested at the factory, there is no assembly required. The unit is ready to be
plugged in to a power outlet. To run the different operating modes, see the next page. To enhance
the beams use this effect with a fog machine.
Fuse Replacement: Locate and remove the unit’s power cord. Once the cord has been removed
located the fuse holder located inside the power socket. Insert a flat-head screw driver into the power
socket and gently pry out the fuse holder. Remove the bad fuse and replace with a new one. The fuse
holder has a built-in socket for a spare fuse be sure not to confuse the spare fuse with active fuse.
©Eliminator® Los Angeles, CA. - www.EliminatorLighting.com
Caution! Never open unit when in use.
Always disconnect main power before
servcing. Remember to always replace
with the exact same type fuse.
Auto Run Mode:
1. Plug the fixture in and press the MODE button until “AU.XX” is displayed. “XX” represents the
current set running speed.
2. Press ENTER and use the UP and DOWN buttons to adjust the running speed. The running
speed can be adjusted between “AU.00” (slowest speed) to “AU.99” (fastest speed).
Sound Active Mode:
In this mode the LED Cloud will react to sound.
1. Plug the fixture in and press the MODE button until “SU.XX” is displayed. “XX” represents the
sound senstivity level.
2. Press ENTER and use the UP and DOWN buttons to adjust the sound sensitivity, the sensitivity
can be adjusted between “SU.01” (least sensitive) to “SU.99” (most sensitive).
DMX Mode:
Operating through a DMX controller gives the user the freedom to create their own programs tailored
to their own individual needs. The LED Mushroom has 3 DMX channels. See the chart on the next
page for the DMX traits and values.
1. This function will allow you to control each individual fixture’s traits with a standard DMX 512
controller.
2. To run your fixture in DMX mode press the MODE button until “AXXX” is displayed. “XXX” repre-
sents the current displayed DMX address. Press ENTER and use the UP or DOWN buttons to
find your desired DMX address.
3. After you have chosen your desired DMX address plug in the fixture via the XLR connections to
any standard DMX controller.
Master-Slave Configuration:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data
cables to link your units together. Remember that the Male XLR connector is the input and the
Female XLR connector is the ouput. The first unit in the chain (master) will use the female XLR
connector only. The last unit in the chain will use the male XLR connector only.
2. Connect the rst “Slave” unit to the “Master.”
3. Set the “Master” unit to your desired mode of operation. On the “Slave” unit, set the DMX
address to “001”. The “Slave” unit will now follow the “Master”.
©Eliminator® Los Angeles, CA. - www.EliminatorLighting.com