structions herein are subject to change without notice. Eliminator logo and identifying product names
and numbers herein are trademarks of Eliminator Lighting. Copyright protection claimed includes all
forms and matters of copyrightable materials and information now allowed by statutory or judicial law
or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-Eliminator brands and
product names are trademarks or registered trademarks of their respective companies.
Eliminator Lighting and all afliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as a
result of the improper, unsafe, insufcient and negligent assembly, installation, rigging, and opera-tion
Junostraat 2 6468 EW Kerkrade, The Netherlands
+31 (0)45 546 85 00 | Fax +31 45 546 85 99
www.americandj.eu | info@americandj.eu
ADJ PRODUCTS GROUP Mexico
AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this
document may be available online.
Please check www.adj.com for the latest revision/update of this manual before
beginning installation and/or programming.
Date
08/10/231.01.00
Document
Version
Software
Version >
DMX Channel ModeNotes
6 / 8 / 9 / 12 / 14 / 15 /
17 Ch
Initial release
2
Page 3
CONTENTS
General Information4
Limited Warranty (USA Only)5
Warranty Registration | Features6
Safety Guidelines7
Overview10
Installation Guidelines11
Accessory Installation15
IR Remote16
Remote Device Management (RDM)18
System Menu19
Operation Modes23
Primary-Secondary Set Up26
DMX Setup27
DMX Traits30
Color Macros Chart32
White Color Temperature Chart33
Dimmer Curve34
Power Linking | Cleaning35
Specications36
Dimensional Drawings37
FCC Statement38
3
Page 4
GENERAL INFORMATION
INTRODUCTION
Please read and understand all instructions in this manual carefully and thoroughly before attempting to
operate these products. These instructions contain important safety and use information. This product
is intended for use by professionally trained personnel only, and is not suitable for private use.
UNPACKING
This xture has been thoroughly tested and has been shipped in perfect operating condition. Carefully
check the shipping carton for damage that may have occurred during shipping. If the carton appears
to be damaged, carefully inspect the unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are missing, please contact
our customer support team for further instructions. Please do not return this kit to your dealer without
rst contacting customer support at the number listed below. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
CUSTOMER SUPPORT
Tel: (323) 213-4592 | Fax: (323) 582-2941
www.adj.com | support@eliminatorlighting.com
WARRANTY RETURNS
All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a
return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return
package. A brief description of the problem as well as the R.A. number must also be written down on a piece
of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of
your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the
package will be refused and returned at customer’s expense. You may obtain an R.A. number by contacting
customer support.
4
Page 5
LIMITED WARRANTY (USA ONLY)
A. Eliminator Lighting, an ADJ Products, LLC brand, hereby warrants, to the original purchaser, Eliminator
Lighting products to be free of manufacturing defects in material and workmanship for a prescribed
period from the date of purchase (see specic warranty period on reverse). This warranty shall be
valid only if the product is purchased within the United States of America, including possessions and
territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service, you must obtain a Return Authorization number (RA#) before sending back the
product-please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product
only to the Eliminator Lighting factory. All shipping charges must be pre-paid. If the requested repairs
or service (including parts replacement) are within the terms of this warranty, Eliminator Lighting
will pay return shipping charges only to a designated point within the United States. If the entire
instrument is sent, it must be shipped in its original package. No accessories should be shipped
with the product. If any accessories are shipped with the product, Eliminator Lighting shall have no
liability whatsoever for loss of or damage to any such accessories, or for the safe return thereof.
C. This warranty is void of the serial number has been altered or removed; if the product is modied
in any manner which Eliminator Lighting concludes, after inspection, affects the reliability of the
product, if the product has been repaired or service by anyone other than ADJ Products, LLC factory
unless prior written authorization was issued to purchaser by Eliminator Lighting; if the product is
damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contact, and this warranty does not include maintenance, cleaning or periodic
check up. During the period specied above, Eliminator Lighting will replace defective parts at
its expense with new or refurbished parts, and will absorb all expenses for warrant service and
repair labor by reason of defects in material or workmanship. The sole responsibility of Eliminator
Lighting under this warranty shall be limited to the repair of the product, or replacement thereof,
including parts, at the sole discretion of Eliminator Lighting. All products covered by this warranty
were manufactured after August 15, 2012, and bear identifying marks to that effect.
E. Eliminator Lighting reserves the right to make changes in design and/or improvements upon its
products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied
with products described above. Except to the extent prohibited by applicable law, all implied warranties
made by Eliminator Lighting in connection with this product, including warranties of merchantability
or tness, are limited in duration to the warranty period set forth above. And no warranties, whether
expressed or implied, including warranties of merchantability or tness, shall apply to this product
after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or
replacement as is expressly provided above; and under no circumstances shall Eliminator Lighting
be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use,
this product.
G. This warranty is the only written warranty applicable to Eliminator Lighting products and supersedes
all prior warranties and written descriptions of warranty terms and conditions heretofore published.
(Such as: Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble
Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
• Laser Products = 1 Year (365 Days) Limited Warranty (excludes laser diodes which have 6
month limited warranty)
• Batteries = 180 Day Limited Warranty (excluding batteries which have a 180 day limited warranty)
5
Page 6
WARRANTY REGISTRATION
Please fill out the enclosed warranty card to validate your purchase. All returned service items,
whether under warranty or not, must be freight pre-paid and accompanied by a return authorization
(R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief
description of the problem as well as the R.A. number must also be written down on a piece of paper
included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof
of purchase invoice. You may obtain an R.A. number by contacting our customer support team. All
pack-ages returned to the service department not displaying an R.A. number on the outside of the
package will be returned to the shipper.
FEATURES
The Eliminator Mega Hex L Par is a compact, LED Par with 4 x 20-Watt, 6-IN-1 (RGBLA + UV) LEDs
and Eliminator’s patented “sit-flat” design so that it may sit directly on the ground or inside truss. It
includes the UC IR24 wireless IR remote control.
INCLUDED ITEMS
•Power Cord (x1)
•UC IR24 wireless remote controller (x1)
•20-degree Filter (x1)
6
Page 7
SAFETY GUIDELINES
To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual.
Eliminator Lighting is not responsible for injury and/or damages resulting from the misuse of this xture
due to the disregard of the information printed in this manual. Only qualied and/or certied personnel
should perform installation of this xture and only the original rigging parts included with this xture
should be used for installation. Any modications to the xture and/or the included mounting hardware
will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT
ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE
AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO
ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION AS FIXTURE SURFACE MAY BE HOT!
AMBIENT OPERATING TEMPERATURE RANGE IS FROM -4°F TO 113°F (- 20°C TO
45°C). DO NOT OPERATE WHEN AMBIENT TEMPERATURE FALLS OUTSIDE THIS
RANGE!
DO NOT TOUCH THE HOUSING WITH BARE HANDS DURING OPERATION, AS
SURFACES MAY BE HOT! TURN OFF THE POWER AND ALLOW ABOUT 15 MINUTES
FOR THE UNIT TO COOL DOWN BEFORE REPLACING OR SERVICING.
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH
AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT,
DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS
A RESULT OF ENVIRONMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL
FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED
ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY
INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
THIS IS A RISK GROUP 3 (HIGH RISK) PRODUCT ACCORDING TO EN 62471 AND
IEC/TR 62778. THE LUMINAIRE SHOULD BE POSITIONED 63 METERS OR MORE
FROM THE OUTPUT OF THE FIXTURE TO REDUCE OR ELIMINATE EXPOSURE.
7
Page 8
SAFETY GUIDELINES
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION!
FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV
COLOR FILTER.
WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE
TO UV COLOR FILTER.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING UV PAINTS ON SKIN. AVOID
DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES LESS THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVERS.
DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH
OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY EXPERIENCE
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
8
Page 9
SAFETY GUIDELINES
THIS FIXTURE IS COMPOSED OF SOPHISTICATED ELECTRONIC COMPONENTS. TO
GUARANTEE SMOOTH OPERATION, IT IS IMPORTANT TO FOLLOW ALL INSTRUCTIONS
AND GUIDELINES IN THIS MANUAL. ELIMINATOR LIGHTING IS NOT RESPONSIBLE FOR
INJURY AND/OR DAMAGES RESULTING FROM THE MISUSE OF THIS FIXTURE DUE TO THE
DISREGARD OF THE INFORMATION PRINTED IN THIS MANUAL. ONLY QUALIFIED AND/OR
CERTIFIED PERSONNEL SHOULD PERFORM INSTALLATION OF THIS FIXTURE AND ONLY
THE ORIGINAL RIGGING PARTS INCLUDED WITH THIS FIXTURE SHOULD BE USED FOR
INSTALLATION. ANY MODIFICATIONS TO THE FIXTURE AND/OR THE INCLUDED MOUNTING
HARDWARE WILL VOID THE ORIGINAL MANUFACTURER’S WARRANTY AND INCREASE THE
RISK OF DAMAGE AND/OR PERSONAL INJURY. ONLY CERTIFIED PERSONNEL SHOULD
PERFORM INSTALLATION OF THIS FIXTURE.
• PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.
• THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
• DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR
MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS
FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN
THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
• DO NOT PLUG FIXTURE INTO A DIMMER PACK!
• NEVER OPEN THIS FIXTURE WHILE IN USE!
• UNPLUG POWER BEFORE SERVICING FIXTURE!
• NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
• KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
• RETINA INJURY RISK - MAY INDUCE BLINDNESS! NEVER LOOK DIRECTLY INTO THE LIGHT
SOURCE!
• SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• INDOOR / DRY LOCATIONS USE ONLY!
• DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
• MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.6 FEET (0.5 METERS)
• MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 8.5 INCHES (22
CM).
• DO NOT TOUCH the xture housing during operation. Turn OFF the power and allow
approximately 15 minutes for the xture to cool down before serving.
• DO NOT shake xture, and avoid brute force when installing and/or operating xture.
• DO NOT operate xture if the power cord is frayed, crimped, damaged and/or if any of the power
cord connectors are damaged and do not insert into the xture securely with ease.
• NEVER force a power cord connector into the xture. If the power cord or any of its connectors
are damaged, replace it immediately with a new one of the same power rating.
• DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked.
Allow approx. 20” (15cm) between xture and other devices or a wall for proper cooling.
• When installing xture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, and always install xture with an appropriately rated safety cable.
• Always disconnect xture from main power source before performing any type of service and/or
cleaning procedure.
• Only handle the power cord by the plug end. Never pull out the plug by tugging the wire portion of
the cord.
• During the initial operation of this xture, a light smoke or smell may emit from the interior of the
xture. This is a normal process and is caused by excess paint in the interior of the casing burning
off from the heat associated with the lamp and will decrease gradually over time.
• Consistent operational breaks will ensure xture will function properly for many years.
• Only use original packaging and materials to transport the xture in for service.
9
Page 10
OVERVIEW
DMX
Out
Display
Screen
Yoke
Adjustment
Knob
Power
Out
Mounting
Yoke
Yoke
Adjustment
Knob
DMX
In
Mode
Button
Setup
Button
Down
Button
Up
Button
Power
In
Fuse
10
Page 11
INSTALLATION GUIDELINES
FLAMMABLE MATERIAL WARNING
Keep xture at least 7.9in. (0.2m) away from any ammable materials, decorations,
pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualied electrician should be used for all electrical connections and/or
installations.
MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 1.6 FEET (0.5 METERS)
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction
codes and regulations. Before rigging/mounting the xture to any metal truss/structure or placing the
xture on any surface, a professional equipment installer MUST be consulted to determine if the metal
truss/structure or surface is properly certied to safely hold the combined weight of the xture, clamps,
cables, and accessories.
Overhead xture installation must always be secured with a secondary safety attachment, such as an
appropriately rated safety cable that meets all local, national, and country codes and regulations.
Fixture ambient operating temperature range is -4°F to 113°F. (-20°C to 45°C). Do not use this xture
when ambient temperature falls outside of this range!
Fixture should be installed away from walking paths, seating areas, or areas where unauthorized
personnel might reach the xture by hand.
NEVER stand directly below the xture when rigging, removing, or servicing.
Allow approximately 15-minutes for the xture to cool down before servicing.
11
Page 12
INSTALLATION GUIDELINES
NOTICE: The suitable environmental temperature for this lighting xture is -4˚F to 113˚F (-20˚C to
45˚C). Do not place this lighting xture in an environment where the temperatures fall outside of this
range. This will allow the xture to run at its best and help prolong the xture life.
MOUNTING
CLAMP
SAFETY
CABLE
LOOPED
AROUND
MOUNTING
YOKE
MOUNTING
YOKE
Align the hole of a mounting clamp with the hole in the mounting yoke, then insert an M12 screw through
the aligned holes and secure in place with a locking nut. Loop one end of an appropriately rated safety
cable (not included) around the mounting yoke, and attach the other end to a secure mounting surface
or mounting point. The clamp should be rated for at least 10 times the weight of the xture, and
the safety cable should be rated for at least 12 times the weight of the xture. Never stand directly
below the unit when mounting, removing, or servicing the unit.
Overhead mounting requires extensive experience, including calculating working load limits, installation
material being used, and periodic safety inspection of all installation material and unit. If you lack these
qualications, do not attempt the installation yourself.
NOTE: These installations should be checked by a skilled person once a year.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIX-
TURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL
NOT DROP IF THE CLAMP FAILS.
12
Page 13
INSTALLATION GUIDELINES
The xture is fully operational in three different mounting positions: hanging upside-down, mounted
sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 0.2m (8in.) away
from any ammable materials (decoration etc.). Always use an appropriately rated safety cable as a
safety measure to prevent accidental damage and/or injury in the event the clamp fails. Never use the
carrying handles for secondary attachment.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPEND-
ED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS.
CAUTION: Falling xtures can cause severe injury or serious equipment damage! For this rea-
son, xtures should be installed and inspected only by qualied personnel. Do not in-stall the
unit if you lack the qualications to do so, or if you have doubts about the safety and security
of the installation setup or location!
13
Page 14
INSTALLATION GUIDELINES
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting moving head xtures, and lasers, which
are focused directly towards the exterior housing and/or penetrate the front lens opening of Eliminator
lighting xtures, can cause severe internal damage including burning to optics, dichroic color lters,
glass and metal gobos, prisms, animation wheels, frost lters, iris, shutters, motors, belts, wiring,
discharge lamps, and LEDs.
This issue is not specic only to Eliminator lighting xtures, it is a common issue with lighting xtures from
all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines
below can prevent any potential damage from occurring if followed. Contact ADJ Service for more details.
DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM
DIRECT SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE
UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS
A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.
14
Page 15
ACCESSORY INSTALLATION
FROST FILTER
To install the optional frost lter, pinch the lter in the middle, being careful not to create creases. Guide
the edges of the lter into the slots on either side of the xture’s lens, then slowly release the lter and
allow it to unfold until it sits at against the xture lens.
Frost
Filter
Fixture
Lens
Frost
Filter
(folded)
(flat)
Slots
15
Page 16
IR REMOTE
The unit can only be controlled when it has been set to Primary mode. The unit will NOT respond to commands when it has been set to Secondary mode. When using the remote to control
multiple units that are operating in primary/secondary mode, follow these steps to set up the units:
1. Power on the unit, and press MODE to scroll to the “Personality” menu.
2. Press SETUP, then use the UP and DOWN buttons to scroll to “Prim/Sec Mode”, and press SETUP
to select this sub-menu.
3. Use the UP and DOWN key to toggle between “Primary” and “Secondary”. Press SETUP to conrm
and return to the “Personality” menu.
4. Use UP and DOWN to scroll to “IR Remote” and press SETUP to select this sub menu. Use UP and
DOWN to switch this setting ON. Repeat these steps for each unit.
NOTES:
• Only one unit should be congured as the primary, while all the other units should be congured as
secondaries.
• All units should be set to the same DMX channel mode.
• If xtures fail to sync, verify that all settings mentioned above are the same, then power all devices
off, then switch them on again to re-establish the link.
UC IR24 CONTROLS
• On: Fixture turns on and reverts to the last running state
• Off: Fixture goes into stand by mode in a blackout state.
• Strobe: Actives strobe mode. The strobe rate can be adjusted
using the + / - buttons, or a pre-set strobe speed can be directly accessed using the number buttons (1-15). 1 is the slowest
strobe speed, and 15 is fastest.
• Sound: The unit plays the last selected program based on
sound inputs. Microphone sensitivity can be adjusted using the +
/ - buttons.
• Color: Activates color mode. Select a static color (0-15) using
the number keys. The intensity for the set color can then be adjusted with the + / - buttons.
• Program: Activates program mode. Select an internal program
(0-15) using the number keys. The selected program run speed
can be adjusted with the + / - buttons. Note: only buttons 0-13
will activate a program for this unit.
• + and - buttons: Adjusts strobe rate, mic sensitivity, intensity, or
program run speed. The +/- buttons can be repeatedly pressed
to increase or decrease by individual level increments, or
pressed and held to quickly make large adjustments at once.
• Number Keys (0-15): These buttons are used to select preset
static colors and internal programs. Colors stored in the number
keys can be edited from the units menu if desired.
16
Page 17
IR REMOTE
REMOTE BUTTON COLOR ASSIGNMENT
The number keys (0-15) on the UC IR24 remote can each be programmed with a specialized color mix.
The default factory color programs that are assigned to these keys are shown in the table below.
These values can also be edited by the user by following the steps below:
1. Press MODE to scroll to the “Personality” menu, and press SETUP to select this sub-menu.
2. Use the UP and DOWN buttons to scroll to “IR Button Colors”, and press SETUP to select this op-
tion.
3. Use the UP and DOWN key to scroll to the number of the button you wish to edit, then press SETUP
to select.
4. Use UP and DOWN to scroll to a color component, press SETUP to select the color component
shown, and then use UP and DOWN to scroll to the desired intensity value. Press SETUP to conrm, and repeat for each color component until you achieve your desired color mix.
5. Repeat steps 3 and 4 for any other remote button color you wish to edit.
6. To return these color assignments to the factory settings, navigate to Personality > Service, enter
the passcode, select Factory Restore, and select YES. Press SETUP to conrm.
17
Page 18
REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout
the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for
as a GET command). The controller can then use its SET command to modify settings that would
typically have to be changed or viewed directly via the unit’s display screen, including the DMX Address, DMX Channel Mode, and Temperature Sensors.
FIXTURE RDM INFORMATION:
Device IDDevice Model IDRDM CodePersonality ID
6Ch (1)
8Ch (2)
9Ch (3)
0000-FFFF96DC1900
12Ch (4)
14Ch (5)
15Ch (6)
17Ch (7)
Please be aware that not all RDM devices support all RDM features, and therefore it is important
to check beforehand to ensure that the equipment that you are considering includes all of the features that you require.
The following parameters are accessible in RDM on this device:
The xture includes an easy to navigate system menu. The control panel located on the front of the
xture, provides access to the main system menu and is where all necessary system adjustments are
made to the xture. During normal operation, pressing MODE button once will access the xture’s
main menu. Once in the main menu you can navigate through the different functions and access the
sub-menus with the UP and DOWN buttons. Once you reach a eld that requires adjusting, press the
SETUP button to activate that eld and use the UP and DOWN buttons to adjust the eld. Pressing the
SETUP button once more will conrm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.
TOUCH SCREEN LOCK
This function allows the user to congure whether or not the display screen and control panel keys
will lock after a certain period of inactivity. It can be accessed by navigating to Personality > Display >
Touch Screen Lock in the system menu. To unlock the screen, press and hold anywhere on the touch
screen for at least 3 seconds.
SERVICE PORT / SOFTWARE UPDATES
Please contact ADJ customer support or latest software and updating instructions.
19
Page 20
SYSTEM MENU
DMX
SETTINGS
PERSONALITY
Address001 - 496
6ch
8ch
Channel
Mode
No DMX
Status
Prim/Sec
Mode
Dim Mode
Dim Curve
9ch
12ch
14ch
15ch
17ch
Hold Last
Blackout
Manual Settings
Internal Programs
Primary / Secondary
Standard
Stage
TV
Architectural
Theatre
Stage 2
Dim Speed00 - 99
Square
Linear
Inv. Squa
S. Curve
Set DMX starting
address
Select DMX
channel mode
Unit holds channels
at the last values
received when DMX
signal is lost
Unit takes all
channels to 0 when
DMX signal is lost
Unit takes all
channels to last
manual settings
when DMX signal is
lost
Unit takes all
channels to last set
internal program
when DMX signal is
lost
Set unit to run
as primary or
secondary
Select dim mode
Select dim curve
CONTINUED ON NEXT PAGE
20
Page 21
SYSTEM MENU
PERSONALITY
(continued)
RMDOn / Off
Saver DelayOff, 1sec - 10sec
Display
Language
IR RemoteOn / Off
IR Button
Colors
Service
Screen LockOff, 30sec, 2min - 10min
Rotate Display
180°
Passcode
(050)
Button 0
Button 1
.........
Button 15
Passcode
(011)
Activate/deactivate
RDM
Screen will shut
off after selected
period of inactivity
This device features 5 different operation modes which can be selected from the main system menu.
These are easily configured and operated from the included UC IR24 remote, or in some cases the
display screen and its control buttons. Follow the directions below to set up and operate each mode.
AUTO RUN MODE: The unit will cycle through a set of 14 pre-set internal programs (Program 0, plus
Program 1 to Program 13). Speed, fade, and sound reaction are adjustable.
Display Screen Control:
1. From the main system menu, press UP and DOWN to navigate to “Internal Programs”, then press
SETUP.
2. Use the UP and DOWN buttons to scroll through the program options, from Program 0 through
Program 13. Press SETUP to select the desired program.
3. Use the UP and DOWN button to scroll to “Speed” and select the speed at which the unit will cycle
through the steps of the selected program. 1 is the slowest, and 255 is the fastest.
4. Use the UP and DOWN button to scroll to “Fade” and select how gradually you want the unit each
step of the selected program to fade in and out. 0 has no fade at all, 1 has a least fade, and 255
has the most. Please note that sound reaction, if activated, overrides the fade.
5. Use the UP and DOWN button to scroll to “Sound” and toggle this setting off.
Remote Control:
1. Press the PROGRAM button on the remote to enter Auto Run mode.
2. Use the number buttons to select your desired program. Please note that only buttons 0 to 13 will
select a valid program.
3. Use the + and - buttons to adjust the program speed. The buttons can be repeatedly pressed to
change the speed in increments, or they can be held down to make large adjustments.
SOUND ACTIVE MODE: The unit will cycle through the steps of the selected program according to
inputs from the built-in microphone.
Display Screen Control:
1. From the main system menu, press UP and DOWN to navigate to “Internal Programs”, then press
SETUP.
2. Use the UP and DOWN buttons to scroll through the program options, from Program 0 through
Program 13. Press SETUP to select the desired program.
3. Use the UP and DOWN buttons to select “Sound” and press SETUP to select this option. (Please
note that the “Speed” and “Fade” options can be ignored, as they will be overriden when Sound is
switched on). Use the UP and DOWN buttons to toggle this setting ON, and press SETUP.
4. Use the UP and DOWN to scroll to the desired sound sensitivity number, then press SETUP to
confirm.
Remote Control:
1. Press the SOUND button on the remote to enter Sound Active mode.
2. Use the + and - buttons to adjust thesound sensitivity level. The buttons can be repeatedly
pressed to change the speed in increments, or they can be held down to make large adjustments.
23
Page 24
OPERATION MODES
RGBLA + UV DIMMER MODE: The unit displays a single, custom mixed static color.
Display Screen Control:
1. From the main system menu, press UP and DOWN to navigate to “Manual Control”, then press
SETUP.
2. Use the UP and DOWN buttons to scroll through the following menu options: Red, Green, Blue,
Lime, Amber, UV, and Master Dimmer. Press SETUP to select the desired option.
3. Use the UP and DOWN button to select the desired value for the selected option, then press
SETUP to confirm. Selectable values range from 000 to 255.
4. Repeat steps 2 and 3 for each menu option. The unit should now steadily display the color mix
that you have created.
Remote Control:
1. Press the COLOR button on the remote to enter Color mode.
2. Use the number buttons to select one of the pre-loaded default color settings. See the IR Remote
section of this manual for detailed info on these default settings.
3. Alternately, you can create a custom color mix for one of more of the number buttons. See the IR Remote section for the detailed procedure on creating custom values.
4. Use the + and - buttons to adjust the intensity of the displayed color. The buttons can be repeat-
edly pressed to change the speed in increments, or they can be held down to make large adjustments.
STATIC COLOR MODE: The unit will display a single pre-programmed color macro. Only available
using Display Screen control.
1. From the main system menu, press UP and DOWN to navigate to “Manual Control”, then press
SETUP.
2. Use the UP and DOWN buttons to scroll to the “Color Macros” option, then press SETUP.
3. Use the UP and DOWN buttons to set the “Color Macros” to the desired value. Refer to the Color Macros Chart section of this manual for information about which colors are represented by each
value. Press SETUP to confirm.
24
Page 25
OPERATION MODES
DMX CONTROL MODE: Control the unit using a DMX controller. Only available from Display Screen
Control.
1. Use a DMX cable to connect the output port of your DMX controller to the DMX Input port of your
first fixture. If multiple units will be running off the controller, then connect the DMX Output port
of your first fixture to the DMX Input port of the next fixture, continuing until all fixtures are daisy-chained together via their DMX Input and Output ports. Refer to the DMX Setup section of this
manual for detailed information about DMX connections.
2. From the main system menu, press UP and DOWN to navigate to “DMX Settings”, then press
SETUP.
3. Use the UP and DOWN buttons to scroll to the “Address” option, then scroll to the desired channel
and press SETUP to confirm. This channel represents the channel at which the fixture will begin to
listen to the DMX signal.
• If you want all of your xtures to react in the same way, then all xtures should be set to the
same DMX starting address.
• If you want each of your xtures to react differently, then each xture’s DMX address that is
spaced apart from the previous xture’s DMX address by the number of DMX channels that the
xtures have been set to run. For example, when running in a mode with 6 DMX channels, unit
addresses should be set to 1, 7, 13, 19, etc.
For detailed information, please refer to the DMX Setup section of this manual.
4. Use the UP and DOWN buttons to scroll to the “Channel Mode” option, and select the DMX channel mode that you would like the fixture to operate in. Press SETUP to confirm. Please refer to the
DMX Traits section of this manual for detailed information.
5. Use the UP and DOWN buttons to scroll to the “No DMX Status” option, then press SETUP to
select. Use the UP and DOWN buttons to select the option for how you would like the unit to
behave when DMX signal is lost or interrupted, then press SETUP to confirm. Please refer to the
System Menu section for detailed descriptions of each option.
25
Page 26
PRIMARY-SECONDARY SET UP
This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit
will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any
unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can
be programmed to act as the Primary.
Primary-Secondary Connections and Settings:
1. Daisy chain your units via the XLR connectors on the rear panels of each unit. Use standard XLR
data cables to link your units together. Remember that the male XLR connector is the input and
the female XLR connector is the ouput. The first unit in the chain (primary) will use the female XLR
connector only. The last unit in the chain will use the male XLR connector only.
2. Use the display screen and control panel to navigate to the Personality > Prim/Sec Mode, and
press ENTER.
3. The fixture can be set to Primary or Secondary. Select one or the other, depending on which mode
you would like the current fixture to use.
4. Make sure that only one unit is designated as the Primary, while all other units are designated as
Secondaries.
5. The secondary units will act in conjunction with the primary unit.
26
Page 27
DMX SETUP
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication
between intelligent xtures and controllers. A DMX controller sends DMX data instructions from the
controller to the xture. DMX data is sent as serial data that travels from xture to xture via the DATA
“IN” and DATA “OUT” XLR terminals located on all DMX xtures (most controllers only have a DATA
“OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible when
linking several DMX xtures. The order in which xtures are connected in a DMX line does not inuence
the DMX addressing. For example, a xture assigned a DMX address of 1 may be placed anywhere in
a DMX line: at the beginning, at the end, or anywhere in the middle. When a xture is assigned a DMX
address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter
where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): This unit can be controlled via DMX512 protocol. Your unit and your DMX controller requires a 3-pin XLR connector for data input/output.
We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your
cables should be made with a male XLR connector on one end and a female XLR connector on the
other. Also remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to the gures below when making your own cables. Do not use the ground lug on
the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short
circuit and erratic behavior.
27
Page 28
DMX SETUP
Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the
female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors: Some manufacturers use 5-pin DMX-512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be integrated into a 3-pin DMX line with a 5-pin to
3-pin adapter cable. These adapters are readily available at most electronics stores. Follow the chart
below for a proper conversion.
28
Page 29
DMX SETUP
DMX Addressing:
All xtures should be given a DMX starting address when using a DMX controller, in order to ensure
that the correct xture responds to the correct control signal. This digital starting address is the channel
number from which the xture starts to “listen” to the digital control signal sent out from the DMX
controller. The assignment of this starting DMX address is achieved by setting the correct DMX address
on the digital control display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set different addresses for
each individual xture. Setting all xtures to the same DMX address will cause all xtures to react in the
same way; in other words, changing the settings of one channel will affect all the xtures simultaneously.
If you set each xture to a different DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each xture. That means changing the settings
of one channel will only affect the selected xture. For instance, when this unit is set to 6 Channel
mode, you should set the starting DMX address of the rst unit to 1, the second unit to 7 (1 + 6), the
third unit to 13 (1 + 6 + 6), the fourth unit to 19 (1 + 6 + 6 + 6), etc...
1111111000 - 255All Red, 0% to 100%
2222222000 - 255All Green, 0% to 100%
3333333000 - 255All Blue, 0% to 100%
4444444000 - 255All Lime, 0% to 100%
5555555000 - 255All Amber, 0% to 100%
6666666000 - 255All UV, 0% to 100%
777000 - 255
888000 - 255Color Temperature, 2300K - 9900K Linear
999
771071010
881181111000 - 255Dimmer Intensity, 0% to 100%
91291212000 - 255Dimmer Fine
101313
111414000 - 255Auto Programs Speed, slow to fast
DMX
VALUES
000 - 022Open
023 - 099
100 - 255No function
000 - 031LEDs Off
032 - 063LEDs On
064 - 095Strobe Effect, slow to fast
096 - 127LEDs On
128 - 159Pulse Effect in Sequences
160 - 191LEDs On
192 - 223Random Strobe Effect, slow to fast
224 - 255LEDs On
000 - 010Off
011 - 026Auto Program 1
027 - 043Auto Program 2
044 - 060Auto Program 3
061 - 076Auto Program 4
077 - 093Auto Program 5
094 - 110Auto Program 6
111 - 126Auto Program 7
127 - 143Auto Program 8
144 - 160Auto Program 9
161 - 176Auto Program 10
177 - 193Auto Program 11
194 - 210Auto Program 12
211 - 226Auto Program 13
227 - 255No function
FUNCTION
Color Macros, see Color Macros Chart
section of this manual
White Color Temperature Presets
See White Color Temperature Chart
section of this manual
Shutter, Strobe
Auto Programs
CONTINUED ON NEXT PAGE
30
Page 31
DMX TRAITS
CHANNEL
6Ch8Ch9Ch12Ch14Ch15Ch17Ch
121515000 - 255 Auto Programs Fade, least to most
1316
1417
DMX
VALUE
000 - 020 Default to unit setting
021 - 040 Standard
041 - 060 Stage
061 - 080 TV
081 - 100 Architectural
101 - 120 Theatre
121 - 140 Stage 2
Rise Time (ms)Down Time (ms)Rise Time (ms)Down Time (ms)
Standard (default)0000
Stage780110015401660
TV1180152018601940
Architectural1380173020402120
Theatre1580194022302280
100%
Output
100%
Output
100%
Output
100%
Output
0
0
0
34
0
Page 35
POWER LINKING
This feature allows multiple units to be linked together by way of the power input and output sockets.
The maximum number of devices that can be connected in this manner is as follows:
• 20 units @ 120v
• 40 units @ 230v
After this quantity has been reached, a new power outlet must be used to accommodate additional
devices.
Linked devices must be of the same make and model type. DO NOT mix devices!
CLEANING
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried
out periodically to optimize light output.
• Use normal glass cleaner and a soft cloth to wipe down the outside casing.
• Clean the external optics with glass cleaner and a soft cloth every 20 days.
• Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the xture operates (i.e. smoke, fog residue,
dust, dew).
35
Page 36
SPECIFICATIONS
• Vibrant slim at black Par with 4 x 20-Watt, 6-IN-1 Hex (RGBLA+UV) LEDs
• HEX LEDs allow for a wider pallet of colors like hot pink, lime green and electric blue
• With the newly added Lime LED chips, the unit can achieve much higher CRI, which means better light
quality
• Smooth Color Mixing (fast or slow color change operation)
• Patented “sit-at” design: Power & DMX Ins/Outs intelligently designed so the xtures may be set at on
the ground or set inside truss
• Great as an architectural wall wash or for performance stages where traditional stage lighting emits a lot of
heat onto performers
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interfer-
ence received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This equipment has been tested and found to comply with the limits for a class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable pro-
tection against harmful interference in a residential installation. This device uses and can radiate radio
frequency energy, and if not installed and used in accordance with the included instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to
try to correct the interference by one or more of the following methods:
• Reorient or relocate that device.
• Increase the separation between the device and the receiver.
• Connect the device and the receiver to electrical outlets on separate circuits.
• Consult the dealer or an experienced radio/TV technician for help.
Please note that the changes or modifications of this product that are not expressly approved
by the party responsible for compliance could void the user’s authority to operate the equipment.
38
Page 39
This page intentionally left blank.
39
Page 40
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.