ELGO Electronic MTM-A-000 Series Operating Manual

Operating Manual
SERIES MTM-A-000
Magnetic-translational Absolute Measuring System
Permanent position detection even in power-off condition Position / path determination at round profile rods Wear-free, contactless measurement principle Very robust and proven measuring technology Interface: Analog output or CANopen High shock and vibration resistance Insensitive to contamination Power supply 10 … 30 VDC
799000850 / Rev. 0 / 2019-03-08 Translation of the original operating manual
- 2 -
Publisher
ELGO Electronic GmbH & Co. KG
Carl-Benz-Str. 1 D-78239 Rielasingen-Worblingen
Technical Support
 +49 (0) 7731 9339 - 0  +49 (0) 7731 2 88 03
info@elgo.de
Document- No.
799000850
Document- Name
MTMA-000-MA-E_10-19
Document- Revision
Rev. 0
Issue Date
2019-03-08
Copyright
© 2019, ELGO Electronic GmbH & Co. KG
Contents
- 3 -

1 Contents

1 Contents ............................................................................................. 3
2 List of Figures ..................................................................................... 4
3 List of Tables ...................................................................................... 4
4 General, Safety, Transport and Storage ........................................... 5
4.1 Information Operating Manual ............................................................................. 5
4.2 Explanation of Symbols ........................................................................................ 5
4.3 Statement of Warranties ....................................................................................... 6
4.4 Demounting and Disposal .................................................................................... 6
4.5 General Causes of Risk ........................................................................................ 6
4.6 Personal Protective Equipment ............................................................................... 6
4.7 Conventional Use ............................................................................................... 7
4.8 Safety Instructions for Transport, Unpacking and Loading .......................................... 7
4.9 Handling of Packaging Material ............................................................................ 7
4.10 Inspection of Transport ........................................................................................ 7
4.11 Storage ............................................................................................................. 7
5 Product Features ................................................................................ 8
5.1 Principle of Scanning ........................................................................................... 8
5.2 The absolute Measuring Principle .......................................................................... 8
5.3 Available Output Signals ...................................................................................... 8
6 Technical Data ................................................................................... 9
6.1 Identification ...................................................................................................... 9
6.2 Dimensions of the MTM-A Standard Housing .......................................................... 9
6.3 Technical Data MTM-A-000 ............................................................................... 10
6.4 Usable Round Rod Diameters ............................................................................. 10
6.5 Usable Cylinder Diameters ................................................................................. 10
7 Sensor adaption to Round Rod and Cylinder .................................. 12
7.1 Integration Example .......................................................................................... 12
8 Installation and First Start-Up ......................................................... 13
8.1 Operating Area ................................................................................................ 13
8.2 Installation of the Sensor .................................................................................... 14
8.3 Adjustment of Reading Distance and Lateral Offset ................................................. 15
8.4 Calibration of the Measuring Range ..................................................................... 16
9 Connections and Interfaces ............................................................. 18
9.1 Connection Options .......................................................................................... 18
9.2 Analog Output ................................................................................................. 19
9.1 CANopen Interface ........................................................................................... 20
Contents
- 4 -
10 Disturbances, Maintenance, Cleaning ............................................. 21
10.1 Fault Clearance ................................................................................................ 21
10.2 Re-start after Fault Clearance .............................................................................. 21
10.3 Maintenance .................................................................................................... 21
10.4 Cleaning ......................................................................................................... 21
11 Type Designation ............................................................................. 22
11.1 Accessories ...................................................................................................... 22
12 Index ................................................................................................ 24

2 List of Figures

Figure 1: Example of an absolute coded round rod track ............................................................................. 8
Figure 2: Dimensions of the MTM-A standard sensor housing ....................................................................... 9
Figure 3: Sensor adaption examples ......................................................................................................... 12
Figure 4: Integration example via mounting ring ........................................................................................ 12
Figure 5: Alignment of the active sensor area ............................................................................................ 14
Figure 6: Adjustment of reading distance and lateral offset ......................................................................... 15
Figure 7: Angular tolerances .................................................................................................................... 15
Figure 8: TEACH input wiring .................................................................................................................. 16
Figure 9: Standard connection - open cable ends ...................................................................................... 18
Figure 10: Connection option 2 - (5-pin male M12 round connector) ......................................................... 18
Figure 11: CANopen interface ................................................................................................................. 20

3 List of Tables

Table 1: Mounting tolerances .................................................................................................................. 15
Table 2: Analog output with open cable ends ............................................................................................ 19
Table 3: Analog output with 5-pin M12 round connector ........................................................................... 19
Table 4: CANopen with open cable ends .................................................................................................. 20
Table 5: CANopen with 5-pin M12 round connector ................................................................................. 20
Table 6: Accessories ............................................................................................................................... 22
General, Safety, Transport and Storage
- 5 -
DANGER! This symbol in connection with the signal word “Danger” indicates an immediate danger for the life and health of persons. Failure to heed these instructions can result in serious damage to health and even fatal injury.
WARNING! This symbol in connection with the word „Warning” means a possibly impending danger for the life and health of persons. Failure to heed these instructions can result in serious damage to health and even fatal injury.
CAUTION! This symbol in connection with the signal word “Caution” indicates a possibly dangerous situation. Failure to heed these instructions can lead to minor injuries or damage of property.
DANGER!
This symbol in connection with the signal word “Danger” indicates an immediate danger for the life and health of
persons due to voltage. Failure to heed these instructions can result in serious damage to health and even fatal injury. The operations may only be carried out by a professional electrician.
NOTE! points out useful tips and recommendations as well as information for an efficient and trouble-free operation.

4 General, Safety, Transport and Storage

4.1 Information Operating Manual

This manual contains important information regarding the handling of the device. For your own safety and operational safety, please ob­serve all safety warnings and instructions. Precondition for safe operation is the compliance with the specified safety and handling instruc­tions. Moreover, the existing local accident prevention regulations and the general safety rules at the site of operation have to be observed.
Please read the operating manual carefully before starting to work with the device! It is part of the product and should be kept close to the device and accessible for the staff at any time. The illustrations in the manual are for better demonstration of the facts. They are not neces­sarily to scale and can slightly differ from the actual design.

4.2 Explanation of Symbols

Special notes in this manual are characterized by symbols. The notes are introduced by signal words which express the magnitude of danger. Please follow this advice and act carefully in order to avoid accidents, damage, and injuries.
Warning notes:
Special safety instructions:
Tips and recommendations:
Reference marks:
Marks a reference to another chapter of this manual.
Marks a reference to another chapter of another document.
General, Safety, Transport and Storage
- 6 -
CAUTION! Wrong disposal causes environmental damages! Electronic scrap, electronic components, lubricants and other auxiliary materials are subject to special refuse and can only be disposed by authorized specialists!
CAUTION! Please read the operating manual carefully, before using the device! Observe the installation instructions! Only start up the device if you have understood the operating manual. The operating company is obliged to take appropriate safety measure. The initial operation may only be performed by qualified and trained staff. Selection and installation of the devices as well as their embedding into the controlling system require qualified knowledge of the applicable laws and normative requirements on the part of the machine manufacturer.
PROTECTIVE CLOTHING … is close-fitting working clothing with light tear strength, tight sleeves and without distant parts. It serves preliminari­ly for protection against being gripped by flexible machine parts. Do not wear rings, necklaces or other jewelry.
PROTECTIVE GLOVES for protecting the hands against abrasion, wear and other injury of the skin.
PROTECTIVE HELMET for protection against injuries of the head.

4.3 Statement of Warranties

The producer guarantees the functional capability of the process engineering and the selected parameters.

4.4 Demounting and Disposal

Unless acceptance and disposal of returned goods are agreed upon, demount the device considering the safety instructions of this manual and dispose it with respect to the environment.
Before demounting, disconnect the power supply and secure against re-start. Then disconnect the supply lines physically and discharge remaining energy. Remove operational supplies and other material.
Disposal: Recycle the decomposed elements: Metal components in scrap metal, Electronic components in electronic scrap, Recycle plastic components, dispose the remaining components according to their material consistence.
Local authorities and waste management facilities provide information about environmentally sound disposal.
Safety

4.5 General Causes of Risk

This chapter gives an overview of all important safety aspects to guarantee an optimal protection of employees and a safe and trouble-free operation. Non-observance of the instructions mentioned in this operating manual can result in hazardous situations.

4.6 Personal Protective Equipment

Employees have to wear protective clothing during the installation of the device to minimize danger of health.
Therefore: Change into protective clothing before performing the works and wear them throughout the process. Additionally observe the labels regarding protective clothing in the operating area.
Protective clothing:
General, Safety, Transport and Storage
- 7 -
CAUTION! Danger through non-conventional use! Non-intended use and non-observance of this operating manual can lead to dangerous situations.
Therefore:
Only use the device as described Strictly follow the instructions of this manual
Avoid in particular:
Remodeling, refitting or changing of the construction or single components with the intention to alter the
functionality or scope of the device.
CAUTION! Transport the package (box, palette etc.) professionally. Do not throw, hit or fold it.
NOTE! Claim any damage immediately after recognizing it. The claims for damage must be filed in the lawful reclaim periods.
IMPORTANT! When storing the coded rod, it must be explicitly ensured that it is not placed in the vicinity of foreign magnets (refer also to section “Technical Data” 6.3„Environmental Conditions“).

4.7 Conventional Use

The ELGO-device is only conceived for the conventional use described in this manual. The ELGO MTM-A-000 length measuring system only serves to measure positions, lengths and/or speeds.
Claims resulting from damages due to non-conventional use are not possible. Only the operator is liable for damages caused by non-conventional use.

4.8 Safety Instructions for Transport, Unpacking and Loading

4.9 Handling of Packaging Material

Notes for proper disposal: 4.4

4.10 Inspection of Transport

Check the delivery immediately after the receipt for completeness and transport damage. In case of externally recognizable transport damages:
Do not accept the delivery or only accept under reserve. Note the extent of damages on the transportation documents or delivery note. File complaint immediately.

4.11 Storage

Store the device only under the following conditions:
Do not store outside Keep dry and dust-free Do not expose to aggressive media Protect from direct sun light Avoid mechanical shocks Storage temperature ( 6) needs to be observed Relative humidity ( 6) must not be exceeded Inspect packages regularly if stored for an extensive period of time (>3 months)
Product Features
- 8 -
S N S N S N S N S N S N S N

5 Product Features

The MTM-A-000 measuring system is based on the physical principle of magnetism and is used for a high­precision determination of the position, the moved distance and/or the speed. Based on this wear-free and con­tactless absolute measuring system, MTM-A-000 is suitable for fixed round rod profiles - for example for non­rotating piston rods of hydraulic cylinders in mobile automation.
The system consists of the following components:
Round rod resp. piston rod (provided by the customer for absolute coding by ELGO) Application related sensor system (ELGO made) Mechanical accessories for sensor adaptation on request

5.1 Principle of Scanning

In order to determine the absolute position, the basis of the magnetic MTM-A-000 linear encoder consists of a scan­ning technology, which scans the magnetically coded round rod contactless and completely wear-free.
The measured value is processed by the internal evaluation electronics and is available either via a CANopen interface or as an analog output signal (mA or Volt). From here it can be further processed by the subsequent electronics.

5.2 The absolute Measuring Principle

The absolute measuring principle ensures maximum safety, as the current position value is always present. Even in the event of a power failure, no data is lost. The measuring system only needs to be referenced once by learn­ing the upper and lower position (see 8.4 Calibration of the Measuring Range).
Figure 1: Example of an absolute coded round rod track

5.3 Available Output Signals

Depending on the ordered interface option (see type designation 11) the sampled signal information is con­verted by the internal evaluation electronics into one of the following output signals:
Interface option CA0 CANopen standard interface according to DS406 (encoder profile) Interface option I20 Analog 12 bit output signal (0 … 20 mA), proportional to the measured valueInterface option I24 Analog 12 bit output signal (4 … 20 mA), proportional to the measured valueInterface option V04 Analog 12 bit output signal (0.5 … 4.5 V), proportional to the measured valueInterface option V10 Analog 12 bit output signal (0 … 10 V), proportional to the measured value
More information can be found in chapter 9 Connections and Interfaces.
Loading...
+ 17 hidden pages